IS200STCIH2AED GE Mark VI Terminal BoardIS200STCIH2AED GE Mark VI Terminal BoardIS200STCIH2AED GE Mark VI Terminal Board
IS200STCIH2AED GE Mark VI Terminal Board
IS200STCIH2AED GE Mark VI Terminal Board
IS200STCIH2AED GE Mark VI Terminal Board

IS200STCIH2AED GE Mark VI Terminal Board


Only 10 left - Selling fast

PRODUCT SKU : IS200STCIH2AED

PRODUCT TYPE : Terminal Boards

PRODUCT VENDOR : General Electric


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The GE IS200STCIH2AED, also cataloged as the IS200STCI Terminal Board, operates as a dedicated hardware component for field signal termination and input conditioning within GE Mark VI Turbine Control System racks.

Hardware Specifications

Parameter Specification
Model IS200STCIH2AED
Brand GE / General Electric
Origin USA
Weight 0.8 kg
Dimensions 14.75 cm x 9.50 cm x 3.50 cm
Operating Temp Standard Cabinet Operating Range
Power Consumption Passive Field Interface / Backplane Powered
Board Type Compact Contact Input Terminal Board
Signal Interface Field Contact Inputs and Isolation Circuitry

Backplane Bus Communication Velocity and Firmware Flash Compatibility

The IS200STCIH2AED conditions field dry contacts and routes discrete logic states directly to adjacent Mark VI I/O processor modules without introducing signal latencies. Passive impedance-matching networks protect the backplane bus communication velocity across high-density rack configurations. Integrated EEPROM structures provide system identification and maintain firmware flash compatibility during controller startup and automatic board recognition sequences.

Frequently Asked Questions

Q: How does the IS200STCIH2AED terminal board connect to the main Mark VI controller?

A: The board interfaces via multi-pin cable harnesses connected to the corresponding I/O processor card in the Mark VI rack frame.

Q: What physical grounding steps must be observed during terminal board mounting?

A: Secure the 14.75 cm x 9.50 cm x 3.50 cm assembly onto the designated baseplate mounting posts using metallic hardware to establish a direct frame ground path.

Q: Are active component programming steps required upon replacing an IS200STCI unit?

A: No, the onboard non-volatile memory automatically communicates module parameter metadata to the processor to verify configuration alignment.

Field Installation Guidelines

  1. Disconnect all primary rack power feeds and field signal voltage sources before physically servicing the terminal board.
  2. Put on an ESD grounding wrist strap attached to an unpainted metal surface of the control cabinet.
  3. Mount the IS200STCIH2AED onto the enclosure DIN rail or mounting standoffs using the provided mechanical fasteners.
  4. Route field wiring into the terminal block screw connectors, verifying correct conductor polarity and tight clamp engagement.
  5. Secure signal cable shields to the nearest cabinet earth ground bar, maintaining single-point grounding to prevent ground loops.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Multi-Touch HMI Technology: Transforming Interaction in Industrial Automation

Multi-Touch HMI Technology: Transforming Interaction in Industrial Automation

Modern human-machine interfaces (HMIs) are evolving rapidly across factory floors worldwide. Traditional resistive touchscreens allowed operators to register only a single touch point at a time. Today, multi-touch HMI panels enable intuitive multi-finger gestures and concurrent multi-operator inputs in demanding industrial automation setups.

Read more
Centralized vs Decentralized Automation Systems: Architectural Trade-Offs in Modern Industrial Control

Centralized vs Decentralized Automation Systems: Architectural Trade-Offs in Modern Industrial Control

Industrial automation relies heavily on robust control architectures to manage complex processes efficiently. Engineers must choose between centralized and decentralized topologies when designing plant automation. This decision directly impacts system reliability, scalability, and long-term maintenance costs.

Read more
Engineering a Process Control System Philosophy: Principles and Operational Impact

Engineering a Process Control System Philosophy: Principles and Operational Impact

A Process Control System (PCS) Philosophy serves as the foundational blueprint for modern plant engineering. During the design and construction phases, this document establishes clear guidelines for instrumentation and control (I&C) teams. Consequently, a well-defined philosophy directly dictates overall operational stability, maintenance efficiency, and future expansion capabilities across heavy process industries.

Read more