Overview

The GE Fanuc IC697CMM742 is an Ethernet interface module engineered for Series 90-70 PLC systems. It provides robust network connectivity with multiple ports and diagnostic LEDs, allowing reliable integration of PLCs into industrial Ethernet networks. This single-slot module supports high-speed communication, system monitoring, and easy maintenance, making it suitable for critical automation applications.

Technical Specifications

  • Manufacturer GE Fanuc (Emerson Automation)

  • Series Series 90-70

  • Part Number IC697CMM742

  • Product Type Ethernet Interface Module

  • Module Weight 1.19 lbs (0.54 kg)

  • Slot Requirement 1-slot in the PLC CPU rack

  • Network Ports 3 total

    • 10BaseT Port: Ethernet, IEEE 802.3 CSMA/CD

    • 10Base2 Port: Ethernet, IEEE 802.3 CSMA/CD

    • AUI Port: Ethernet, IEEE 802.3 CSMA/CD

  • LED Indicators 4 LEDs: MODULE OK, LAN ONLINE, SERIAL ACTIVE, STATUS

  • Operating Voltage +5 VDC, +12 VDC

  • Current Draw +5 VDC: 2.0 A typical; +12 VDC: 0.5 A maximum (with external AUI transceiver)

  • Internal Fuse 5 x 20 mm, 250V, 1.0A slow-acting

  • Restart Method Pushbutton

Key Features

  • Provides multiple Ethernet ports for flexible network connectivity

  • Single-slot design compatible with Series 90-70 PLC racks

  • LEDs for monitoring module health and network activity

  • Pushbutton restart simplifies troubleshooting and maintenance

  • Supports connection to MS-DOS-based diagnostic tools

Application Scenarios

  • PLC integration into Ethernet-based industrial networks

  • Networked control systems with remote monitoring

  • High-availability communication setups in Series 90-70 PLCs

  • Diagnostics and maintenance of multi-rack PLC networks

FAQs

Q: How many Ethernet ports does the IC697CMM742 provide?
A: It provides three ports: 10BaseT, 10Base2, and an AUI port.

Q: Can it be installed in any PLC rack slot?
A: It requires a single-slot CPU rack location for installation.

Q: How is the module restarted?
A: A pushbutton on the module allows for manual restart without removing the unit.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
The Shift to Flexible IO Modules in Modern Industrial Automation

The Shift to Flexible IO Modules in Modern Industrial Automation

Traditional control systems rely on dedicated Input Output (IO) cards for industrial automation. Each conventional module processes a single signal type, such as Digital Input (DI), Digital Output (DO), Analog Input (AI), or Analog Output (AO). A standard 16-channel card accepts only one specific channel type across all ports. This inflexible hardware design often creates severe engineering bottlenecks during project execution. Engineers frequently must install entirely new cards to accommodate a single extra sensor. Consequently, late design changes increase control cabinet space requirements and drive up project costs.

Read more
DCS Commissioning Steps in Industrial Automation Projects

DCS Commissioning Steps in Industrial Automation Projects

Commissioning a Distributed Control System (DCS) represents a crucial milestone when deploying modern process automation infrastructure. Field engineers must execute systematic verification steps to transition complex control hardware from static installation to dynamic plant control. Proper commissioning ensures that controllers, I/O modules, network switches, and HMI software operate in strict compliance with engineering design specifications before introducing live process fluids.

Read more
PLC and DCS Control System Spares Strategy: Engineering Guidelines

PLC and DCS Control System Spares Strategy: Engineering Guidelines

Modern factory automation relies on high-speed fiber optic backbones to link distributed control systems across noise-intensive industrial environments. Unlike copper wiring, optical fibers transmit data via light pulses, making them completely immune to electromagnetic interference (EMI). Field engineers must master optical cable joining and fusion splicing techniques to guarantee low-loss data transmission across critical Programmable Logic Controller (PLC) and Distributed Control System (DCS) nodes.

Read more