Skip to content

What are you looking for?


You may also like

IC697CMM742 | GE Fanuc 90-70 Ethernet Communication ModuleIC697CMM742 | GE Fanuc 90-70 Ethernet Communication ModuleIC697CMM742 | GE Fanuc 90-70 Ethernet Communication Module
IC697CMM742 | GE Fanuc 90-70 Ethernet Communication Module
IC697CMM742 | GE Fanuc 90-70 Ethernet Communication Module
IC697CMM742 | GE Fanuc 90-70 Ethernet Communication Module

IC697CMM742 | GE Fanuc 90-70 Ethernet Communication Module


Only 10 left - Selling fast

PRODUCT SKU : IC697CMM742

PRODUCT TYPE : Ethernet Interface Module

PRODUCT VENDOR : General Electric


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Overview

The GE Fanuc IC697CMM742 is an Ethernet interface module engineered for Series 90-70 PLC systems. It provides robust network connectivity with multiple ports and diagnostic LEDs, allowing reliable integration of PLCs into industrial Ethernet networks. This single-slot module supports high-speed communication, system monitoring, and easy maintenance, making it suitable for critical automation applications.

Technical Specifications

  • Manufacturer GE Fanuc (Emerson Automation)

  • Series Series 90-70

  • Part Number IC697CMM742

  • Product Type Ethernet Interface Module

  • Module Weight 1.19 lbs (0.54 kg)

  • Slot Requirement 1-slot in the PLC CPU rack

  • Network Ports 3 total

    • 10BaseT Port: Ethernet, IEEE 802.3 CSMA/CD

    • 10Base2 Port: Ethernet, IEEE 802.3 CSMA/CD

    • AUI Port: Ethernet, IEEE 802.3 CSMA/CD

  • LED Indicators 4 LEDs: MODULE OK, LAN ONLINE, SERIAL ACTIVE, STATUS

  • Operating Voltage +5 VDC, +12 VDC

  • Current Draw +5 VDC: 2.0 A typical; +12 VDC: 0.5 A maximum (with external AUI transceiver)

  • Internal Fuse 5 x 20 mm, 250V, 1.0A slow-acting

  • Restart Method Pushbutton

Key Features

  • Provides multiple Ethernet ports for flexible network connectivity

  • Single-slot design compatible with Series 90-70 PLC racks

  • LEDs for monitoring module health and network activity

  • Pushbutton restart simplifies troubleshooting and maintenance

  • Supports connection to MS-DOS-based diagnostic tools

Application Scenarios

  • PLC integration into Ethernet-based industrial networks

  • Networked control systems with remote monitoring

  • High-availability communication setups in Series 90-70 PLCs

  • Diagnostics and maintenance of multi-rack PLC networks

FAQs

Q: How many Ethernet ports does the IC697CMM742 provide?
A: It provides three ports: 10BaseT, 10Base2, and an AUI port.

Q: Can it be installed in any PLC rack slot?
A: It requires a single-slot CPU rack location for installation.

Q: How is the module restarted?
A: A pushbutton on the module allows for manual restart without removing the unit.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Modern manufacturing relies heavily on automated control systems to maximize throughput and maintain product quality. However, unplanned downtime in industrial automation can cost facility operators thousands of dollars per hour. Understanding how programmable logic controllers (PLCs), distributed control systems (DCS), and field instrumentation fail empowers engineering teams to implement robust preventive maintenance strategies.

Read more
Essential Motion Control Commands: A Practical Guide for Engineers

Essential Motion Control Commands: A Practical Guide for Engineers

Automation engineers often rely on precise position and speed control to drive modern factory machinery. Modern industrial systems, such as Programmable Logic Controllers (PLCs) and Distributed Control Systems (DCS), depend heavily on standardized motion instructions. Mastering these commands ensures operational safety, protects mechanical components, and optimizes cycle times across production lines.

Read more
The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

Implementing robust protection in hazardous industrial environments represents a fundamental safety requirement in factory automation. Process facilities often handle volatile gases, dusts, and chemical agents that pose significant combustion risks. Consequently, control system engineers must deploy energy-limiting interfaces to isolate safe-area control cabinets from hazardous-area field instrumentation. This article examines the function, selection, and electrical principles of intrinsic safety barriers within modern PLC and DCS networks.

Read more