Skip to content

What are you looking for?


You may also like

IC694BEM331 | GE Fanuc PACSystems RX3i Genius Bus Controller ModuleIC694BEM331 | GE Fanuc PACSystems RX3i Genius Bus Controller ModuleIC694BEM331 | GE Fanuc PACSystems RX3i Genius Bus Controller Module
IC694BEM331 | GE Fanuc PACSystems RX3i Genius Bus Controller Module
IC694BEM331 | GE Fanuc PACSystems RX3i Genius Bus Controller Module
IC694BEM331 | GE Fanuc PACSystems RX3i Genius Bus Controller Module

IC694BEM331 | GE Fanuc PACSystems RX3i Genius Bus Controller Module


Only 10 left - Selling fast

PRODUCT SKU : IC694BEM331

PRODUCT TYPE : Bus Controller Module

PRODUCT VENDOR : General Electric


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The IC694BEM331 Genius Bus Controller from GE Fanuc PACSystems RX3i series is designed to interface PACSystems RX3i CPUs with Genius I/O serial bus networks. This module provides advanced diagnostics, flexible communication options, and supports multiple device types, making it a versatile solution for distributed control systems.

Technical Specifications

  • Manufacturer GE Fanuc

  • Product Line PACSystems RX3i

  • Part Number IC694BEM331

  • Product Type Genius Bus Controller Module

  • Interface Connects PACSystems RX3i to Genius I/O bus

  • Supported Devices Genius blocks, PLCs with Genius Bus Controllers, Remote Drops, VersaMax I/O, Field Control Stations, Genius Hand-Held Monitor (HHM), multiple host systems

  • Diagnostics Advanced built-in diagnostic capabilities

  • Communications Supports Global Data and Datagrams

  • Message Data Length Up to 128 bytes per message

  • Configurable Data Rates 38.4 Kbaud, 76.8 Kbaud, 153.6 Kbaud (standard or extended)

  • Bus Type Daisy-chained cable; single twisted-pair plus shield or Twinax; fiber optic cable and modems also supported

  • Bus Termination 75, 100, 120, or 150 Ohm resistors required at both ends of electrical bus cable

  • Maximum Bus Length

    • 7800 ft at 38.4 Kbaud

    • 4500 ft at 76.8 Kbaud

    • 3500 ft at 153.6 Kbaud (extended)

    • 2000 ft at 153.6 Kbaud (standard)

  • Maximum Devices Supported 32 devices at all baud rates except 38.4 Kbaud (limited to 16 devices)

  • Isolation 2000 V Hi-Pot; 1500 V transient common mode rejection

  • Weight 0.37 kg

Application Scenarios

  • Distributed control systems requiring Genius bus integration

  • Multi-host environments with complex I/O station configurations

  • Industrial automation setups needing long-distance bus communication

FAQ

Q: What devices can be connected to the Genius bus using this module?  A: Genius blocks, PLCs with Genius Bus Controllers, VersaMax I/O, Field Control Stations, Genius HHM, and multiple hosts.

Q: What is the maximum number of devices supported?  A: Up to 32 devices, except at 38.4 Kbaud where the limit is 16.

Q: What isolation protection is provided?  A: 2000 V Hi-Pot and 1500 V transient common mode rejection.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Importance of Safety Barriers in PLC and DCS Control Systems

Importance of Safety Barriers in PLC and DCS Control Systems

Process industries handle flammable gases and liquids, making electrical instrumentation a constant ignition risk. Engineers designing PLC and DCS networks must implement strict energy-limiting strategies. Intrinsic Safety barriers provide the critical interface that safeguards automation assets and prevents explosions.
Read more
Static UPS vs. Rotary UPS: Technical Evaluation for Industrial Automation

Static UPS vs. Rotary UPS: Technical Evaluation for Industrial Automation

UPS architecture dictates power reliability in process automation. Unplanned voltage sags cause immediate downtime, making robust power backup essential for PLC and DCS networks. This technical guide evaluates the operational principles, key architectures, and tradeoffs between Static and Dynamic Rotary UPS systems.
Read more
Comprehensive Guide to Noise Types in Industrial Automation and Electronics

Comprehensive Guide to Noise Types in Industrial Automation and Electronics

Signal integrity determines reliability in modern industrial automation. Unwanted electrical noise degrades sensor data, distorts 4-20 mA current loops, and drops fieldbus communications. Engineers working with PLC, DCS, and TSI systems must effectively mitigate these disturbances. This technical guide analyzes key internal and external noise sources affecting control systems.
Read more