Product Overview

The GE Fanuc IC200CPUE05 is an advanced CPU module from the VersaMax series, featuring embedded Ethernet connectivity for seamless integration into modern industrial networks. It supports up to 64 I/O modules and 2048 discrete points, offering reliable performance for medium- to large-scale PLC applications. The module provides 64 KB configurable memory, non-volatile flash storage, and battery-backed RAM to safeguard programs, data, and time-of-day settings. Designed for flexible programming, it supports Ladder Diagram, Instruction List, and floating-point operations.

Technical Specifications

  • Manufacturer: GE Fanuc Emerson

  • Series: VersaMax

  • Model Number: IC200CPUE05

  • Product Type: CPU Module with Embedded Ethernet

  • Weight: Approx. 1.1 lbs

  • Dimensions (W x H x D): 126 mm x 128 mm x 69.1 mm

  • Power Requirements: 5 V DC at 220 mA, 3.3 V DC at 570 mA

  • Configurable Memory: 64 KB for programs, registers, and I/O

  • Program Storage: Non-volatile system flash and battery-backed RAM

  • I/O Support: Up to 64 modules, 2048 discrete points

  • Boolean Execution Speed: 0.8 ms/K typical

  • Floating Point Support: Yes

  • Real-Time Clock Accuracy: 100 ppm (±9 sec/day)

  • Embedded Communications: RS-232, RS-485, Ethernet (10 Mbps, half- or full-duplex)

  • Ethernet Port: RJ-45, UTP cable

  • EGD Support: 32 configuration-based exchanges, 100 data ranges per exchange, 1400 bytes per exchange, NTP time synchronization

  • SRTP Connections: 8 simultaneous server connections

  • Run/Stop Switch: Yes

  • DIN Rail Mounting: 100 mm height when mounted with power supply

Key Features

  • Embedded Ethernet interface for direct network integration

  • 64 KB memory for program, data, and analog/digital I/O management

  • Supports Ladder Diagram, Instruction List, and floating-point functions

  • Battery-backed RAM preserves programs and system time

  • Real-time clock with high precision (±0.01%)

  • RS-232 and RS-485 serial ports for versatile communication

  • EZ Program Store compatible for easy program transfers

Applications

  • Core processor for VersaMax PLC automation systems

  • Industrial process control requiring Ethernet connectivity

  • Machine monitoring and control in distributed I/O systems

  • PLC system expansions and networked factory automation

FAQ

Q1: How many I/O points can IC200CPUE05 manage?
It supports up to 64 modules with a maximum of 2048 discrete I/O points.

Q2: Does the CPU module include Ethernet communication?
Yes, it has an embedded Ethernet port with 10 Mbps half- or full-duplex capability.

Q3: What memory features are available?
The module provides 64 KB configurable memory and non-volatile flash with battery-backed RAM.

Q4: Can it perform floating-point calculations?
Yes, it supports floating-point (real) data functions for complex calculations.

Q5: Is program storage safe during power loss?
Yes, the module’s flash memory and battery-backed RAM protect programs, data, and the time-of-day clock.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Modern manufacturing relies heavily on automated control systems to maximize throughput and maintain product quality. However, unplanned downtime in industrial automation can cost facility operators thousands of dollars per hour. Understanding how programmable logic controllers (PLCs), distributed control systems (DCS), and field instrumentation fail empowers engineering teams to implement robust preventive maintenance strategies.

Read more
Essential Motion Control Commands: A Practical Guide for Engineers

Essential Motion Control Commands: A Practical Guide for Engineers

Automation engineers often rely on precise position and speed control to drive modern factory machinery. Modern industrial systems, such as Programmable Logic Controllers (PLCs) and Distributed Control Systems (DCS), depend heavily on standardized motion instructions. Mastering these commands ensures operational safety, protects mechanical components, and optimizes cycle times across production lines.

Read more
The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

Implementing robust protection in hazardous industrial environments represents a fundamental safety requirement in factory automation. Process facilities often handle volatile gases, dusts, and chemical agents that pose significant combustion risks. Consequently, control system engineers must deploy energy-limiting interfaces to isolate safe-area control cabinets from hazardous-area field instrumentation. This article examines the function, selection, and electrical principles of intrinsic safety barriers within modern PLC and DCS networks.

Read more