Skip to content

What are you looking for?


You may also like

IC200ALG331 | GE Fanuc VersaMax 4-Channel 16-Bit Analog Output ModuleIC200ALG331 | GE Fanuc VersaMax 4-Channel 16-Bit Analog Output ModuleIC200ALG331 | GE Fanuc VersaMax 4-Channel 16-Bit Analog Output Module
IC200ALG331 | GE Fanuc VersaMax 4-Channel 16-Bit Analog Output Module
IC200ALG331 | GE Fanuc VersaMax 4-Channel 16-Bit Analog Output Module
IC200ALG331 | GE Fanuc VersaMax 4-Channel 16-Bit Analog Output Module

IC200ALG331 | GE Fanuc VersaMax 4-Channel 16-Bit Analog Output Module


Only 10 left - Selling fast

PRODUCT SKU : IC200ALG331

PRODUCT TYPE : Analog Output Module

PRODUCT VENDOR : General Electric


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The GE Fanuc VersaMax IC200ALG331 Analog Output Module provides four individually isolated channels capable of delivering both current and voltage signals. With high resolution, configurable defaults, and advanced diagnostics, it ensures precise control and reliable performance in industrial automation systems.

Technical Specifications

  • Model / Part Number IC200ALG331

  • Manufacturer GE Fanuc Emerson

  • Product Line VersaMax

  • Product Type Analog Output Module

  • Weight 0.69 lbs (0.31 kg)

  • Channels Four isolated analog outputs

  • Nominal Output Signals 4–20 mA and ±10 VDC

  • Output Range Current mode: +1 to 20 mA; Voltage mode: ±10 VDC

  • Resolution 16-bit digital resolution

  • Analog Resolution Current mode: 381 nA nominal; Voltage mode: 381 µV nominal

  • Accuracy at 25°C ±0.1% maximum of full scale

  • Update Time ≤ 7 ms

  • External Supply Voltage Range +18 to +30 VDC including ripple

  • Current Consumption 100 mA maximum plus load currents

  • Backplane Current Consumption 10 mA at 5 VDC; 115 mA at 3.3 VDC

  • Isolation (Input to Logic) 250 VAC

  • Isolation (Input to Ground) 1500 VAC for 60 seconds

  • Diagnostics High/Low limit, over/underrange, open wire, loss of field power, non-volatile memory fault

  • Configurable Output Default Hold last state or reset to zero

  • Module Width Single slot

  • LED Indicators FLD PWR LED, OK LED

Application Scenarios

  • Precision control of actuators and instrumentation requiring current or voltage signals

  • Multi-channel analog output for distributed automation systems

  • Environments needing advanced diagnostics and isolation for reliable operation

FAQ

Q: How many channels does the IC200ALG331 provide?  A: It offers four individually isolated analog output channels.

Q: What signals are supported?  A: Both current (4–20 mA) and voltage (±10 VDC) outputs are supported.

Q: What is the resolution of the module?  A: It provides 16-bit resolution for precise signal control.

Q: What diagnostic features are included?  A: The module detects high/low limits, over/underrange, open wire, loss of field power, and memory faults.

Comparison with Similar Models

  • IC200ALG320: 4-channel current output, 12-bit resolution, fast update rate

  • IC200ALG326: 8-channel current output, 15-bit resolution, configurable range

  • IC200ALG331: 4-channel current/voltage output, 16-bit resolution, advanced diagnostics

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Master Acceptance Testing: Understanding FAT and SAT in Industrial Control Systems

Master Acceptance Testing: Understanding FAT and SAT in Industrial Control Systems

Factory Acceptance Testing (FAT) and Site Acceptance Testing (SAT) serve as critical quality assurance gateways in complex industrial control systems. Both procedures verify that programmable logic controllers (PLCs), distributed control systems (DCS), and associated field devices meet strict functional specifications. However, executing these tests effectively requires clear delineation between off-site staging and final field commissioning.

Read more
Industrial Networking Essentials: Demystifying Hubs, Switches, and Routers in Control Systems

Industrial Networking Essentials: Demystifying Hubs, Switches, and Routers in Control Systems

Industrial automation relies heavily on robust networking infrastructure to connect programmable logic controllers (PLCs), distributed control systems (DCS), and human-machine interfaces (HMIs). Modern factory automation environments generate vast amounts of real-time operational data across deterministic networks. Understanding the structural differences between hubs, switches, and routers ensures optimal traffic segmentation, minimizes latency, and maintains high network availability.

Read more
Safety Relays in Industrial Automation: Fundamentals, Design Standards, and Fail-Safe Architecture

Safety Relays in Industrial Automation: Fundamentals, Design Standards, and Fail-Safe Architecture

Safety relays form the bedrock of functional safety in modern factory automation, preventing catastrophic equipment failure and protecting plant personnel. While standard electromechanical relays handle basic load switching, they lack the redundant diagnostics required for high-risk industrial environments. Modern industrial automation platforms—including programmable logic controllers (PLCs) and distributed control systems (DCS)—rely on specialized safety relays to monitor field devices and isolate hazards instantly.

Read more