Product Description

The TK-OAV061 is an analog output module from Honeywell, engineered for TDC 3000 and Experion PKS control platforms. It converts digital control signals into precise analog outputs, enabling accurate operation of field devices including control valves, actuators, and variable speed drives. Built for industrial environments, the module provides stable signal transmission with high accuracy and electrical isolation.

Key Specifications

  • Manufacturer: Honeywell

  • Model Number: TK-OAV061

  • Product Type: Analog Output Module

  • Operating Temperature: -20 °C to +60 °C

  • Signal Output: Supports both current (4–20 mA) and voltage (0–10 V) outputs

  • Isolation: Galvanic isolation for secure signal transfer

  • Diagnostics: Built-in status monitoring

  • Compatibility: TDC 3000, Experion PKS systems

  • Dimensions & Weight: Standard Honeywell module form factor, approx. 0.45 kg

Applications

  • Chemical Processing: Flow and pressure control via actuators and valves

  • Power Generation: Steam turbine valve regulation and boiler systems

  • Oil & Gas: Compressor speed management and pipeline control

  • Manufacturing: Variable speed motors and automation device control

  • Water Treatment: Pump and dosing system regulation

FAQ

Q: What does the TK-OAV061 module do?
A: It converts digital control signals into analog outputs for precise field device control.

Q: Which output types are supported?
A: Both current (4–20 mA) and voltage (0–10 V) signals are supported.

Q: How does it improve system reliability?
A: Galvanic isolation and built-in diagnostics provide secure, accurate, and continuous signal transmission.

Q: Which industries commonly use this module?
A: Chemical, power generation, oil & gas, manufacturing, and water treatment sectors.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Mastering PLC Programming: Best Practices for Robust Industrial Automation

Mastering PLC Programming: Best Practices for Robust Industrial Automation

Writing clean PLC code requires discipline, especially regarding memory management. Avoid overusing SET and RESET instructions, as they often complicate debugging. If multiple rungs control the same bit, troubleshooting becomes a nightmare. Instead, focus on energizing a bit in only one location. If your logic requires complex conditions, use branches within a single rung. This approach keeps your code readable, maintainable, and significantly easier to audit during downtime.

Read more
PLC vs. HMI: Distinguishing the Brain from the Interface in Industrial Automation

PLC vs. HMI: Distinguishing the Brain from the Interface in Industrial Automation

In the realm of industrial automation, distinguishing between a Programmable Logic Controller (PLC) and a Human-Machine Interface (HMI) is fundamental. While both devices work in tandem, they serve distinct purposes. The PLC acts as the "brain" of the operation, executing logic, whereas the HMI serves as the "eyes," allowing operators to monitor and interact with the system. Understanding this synergy is essential for any professional designing robust factory automation solutions.

Read more
Selecting the Right Industrial Automation Solution for Modern Manufacturing

Selecting the Right Industrial Automation Solution for Modern Manufacturing

Choosing an effective industrial automation system starts with a thorough process audit. You must identify tasks that are repetitive, labor-intensive, or prone to human error. Not every process requires high-level automation; therefore, prioritize operations that directly impact throughput and quality. By scoping your needs accurately, you avoid over-investing in unnecessary technology. A balanced approach ensures that your capital expenditure aligns with measurable gains in operational efficiency.

Read more