Skip to content

What are you looking for?


You may also like

Honeywell TC-ODJ161 | 16-Channel Isolated Digital Output Module 24VDCHoneywell TC-ODJ161 | 16-Channel Isolated Digital Output Module 24VDCHoneywell TC-ODJ161 | 16-Channel Isolated Digital Output Module 24VDC
Honeywell TC-ODJ161 | 16-Channel Isolated Digital Output Module 24VDC
Honeywell TC-ODJ161 | 16-Channel Isolated Digital Output Module 24VDC
Honeywell TC-ODJ161 | 16-Channel Isolated Digital Output Module 24VDC

Honeywell TC-ODJ161 | 16-Channel Isolated Digital Output Module 24VDC


Only 10 left - Selling fast

PRODUCT SKU : TC-ODJ161

PRODUCT TYPE : Digital Output Module

PRODUCT VENDOR : Honeywell


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The TC-ODJ161 is a high-capacity discrete output module designed for the Honeywell Experion PKS and PlantScape controller platforms. This module provides 16 isolated output points, allowing for the independent switching of 24VDC field loads. Engineered for high-demand industrial environments, it features robust electrical isolation to protect the internal controller backplane from field-side voltage spikes and electrical noise, ensuring consistent uptime in mission-critical applications.

Technical Specifications

  • Model Designation: TC-ODJ161

  • Output Type: Isolated Discrete Digital Output

  • Channel Density: 16 Points

  • Operating Voltage: 24 VDC (Nominal)

  • Current Rating (Individual): Up to 2.0 Amps per channel

  • Total Module Capacity: 8.0 Amps maximum total load

  • Mounting Interface: Standard I/O Rack/Chassis slot

  • Net Weight: 0.20 kg (approx. 0.44 lbs)

  • Lifecycle Status: Discontinued by Manufacturer (Legacy Support available)

Implementation and Load Management

The TC-ODJ161 is frequently utilized for driving high-current field devices such as solenoid valves, motor starters, and large relays. While individual channels can handle peak currents up to 2.0 Amps, system designers must ensure that the simultaneous activation of multiple outputs does not exceed the aggregate 8.0 Amp module limit. Proper heat dissipation within the enclosure is recommended when operating at high current densities.

Frequently Asked Questions

  • What is the benefit of the isolated channel design?

    Isolation ensures that a fault or short circuit on one field device does not propagate to other channels or damage the sensitive electronics of the PLC backplane.

  • Can this module drive AC loads?

    No, the TC-ODJ161 is specifically designed for DC current switching. For AC applications, a dedicated relay or Triac output module should be used.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Mastering Wire Identification in Industrial Automation: The Power of Ferrules and Cross-Ferruling

Mastering Wire Identification in Industrial Automation: The Power of Ferrules and Cross-Ferruling

Proper wire labeling forms the cornerstone of reliable control system installation and long-term maintenance. In complex industrial automation environments, technicians terminate thousands of conductor ends inside control panels, marshalling racks, and field junction boxes. Ferrules serve as individual tube-shaped sleeve markers slipped onto conductors before final termination. While technicians historically relied on pre-printed individual letter rings, modern control panel builders utilize automated ferrule printing machines. These thermal-transfer printers generate durable, single-sleeve heat-shrink tags directly matching approved wiring schematics, significantly accelerating cabinet assembly workflows.

Read more
Understanding Marshalling Cabinets in Industrial Automation and Control Systems

Understanding Marshalling Cabinets in Industrial Automation and Control Systems

Marshalling cabinets serve as the crucial connection hub between field instruments and centralized processing units. In large DCS and PLC control system architectures, hundreds of multipair field cables run from local junction boxes to the central instrument equipment room. The marshalling cabinet houses field terminal blocks, surge arresters, intrinsic safety isolation barriers, and interposing relays. By segregating field field-wiring terminations from sensitive processor hardware, engineers protect expensive controller backplanes from high-voltage transients. Consequently, this modular separation dramatically streamlines maintenance workflows and simplifies system expansion.

Read more
Essential Best Practices for PLC Wiring and Installation in Industrial Automation

Essential Best Practices for PLC Wiring and Installation in Industrial Automation

Successful control system deployment begins with thoroughly reviewing manufacturer technical documentation. Controllers from major brands like Allen-Bradley, Siemens, and Schneider Electric feature unique terminal layouts. Engineers must verify voltage requirements before connecting power cables to prevent catastrophic equipment damage. Standard line connections require strict adherence to regional electrical codes and proper wire color coding. Furthermore, panel builders should always establish a robust low-impedance ground connection using at least 16-AWG copper conductor tied directly to the main plant grounding grid.

Read more