Skip to content

What are you looking for?


You may also like

Honeywell TC-OAH061 (96978274-A01) Isolated Analog Output Module 6-ChannelHoneywell TC-OAH061 (96978274-A01) Isolated Analog Output Module 6-ChannelHoneywell TC-OAH061 (96978274-A01) Isolated Analog Output Module 6-Channel
Honeywell TC-OAH061 (96978274-A01) Isolated Analog Output Module 6-Channel
Honeywell TC-OAH061 (96978274-A01) Isolated Analog Output Module 6-Channel
Honeywell TC-OAH061 (96978274-A01) Isolated Analog Output Module 6-Channel

Honeywell TC-OAH061 (96978274-A01) Isolated Analog Output Module 6-Channel


Only 10 left - Selling fast

PRODUCT SKU : TC-OAHO61

PRODUCT TYPE : Analog Output Module

PRODUCT VENDOR : Honeywell


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The TC-OAH061 (96978274-A01) is a high-performance analog interface module designed for precision control within Honeywell industrial systems. This unit provides six independent, galvanically isolated output channels capable of driving current loops up to 21.0 mA. With a 13-bit digital-to-analog conversion resolution, it ensures highly accurate modulation of field devices such as control valves and variable speed drives. The module is engineered for high-availability environments, featuring an impressive 2546 VDC isolation rating and robust RFI immunity to maintain signal integrity in electrically noisy industrial settings.

Technical Specifications

  • Module Identification: TC-OAH061

  • Associated Part Number: 96978274-A01

  • Channel Configuration: 6 Point, Galvanically Isolated

  • Output Signal Range: 0 to 21.0 mA

  • Digital Resolution: 13 bits across the full 21 mA span

  • Response Logic: 25 ms update rate for all concurrent channels

  • Isolation Rating: 2546 VDC (Channel-to-Channel and User-to-System)

  • Protection Circuitry: Continuous 24 VAC/VDC overvoltage protection

  • Interference Resistance: RFI immunity <2.0% error at 10 V/m (27-1000 MHz)

  • Thermal Management: Power dissipation maximum of 6.7 W

  • Operating Environment: -10°C to +60°C (14°F to 140°F)

  • Physical Dimensions: 96 mm x 96 mm x 48 mm

  • Net Weight: 0.5 kg (approx. 1.1 lbs)

  • Required Terminal Block: TC-TBNH (20-position)

Operational Application

The TC-OAH061 (96978274-A01) is typically deployed in process industries where high-density isolation is required to prevent ground loops and protect the central processing unit from field-side transients. Its fast 25 ms update rate makes it suitable for dynamic control loops requiring rapid adjustment of actuators or frequency converters.

Frequently Asked Questions

  • Does this module support voltage output modes?

    The TC-OAH061 is optimized for current loop signaling (0-21 mA). For 0-10V applications, a dedicated voltage output module or external precision resistor may be required.

  • Is the terminal block included with the module?

    The TC-TBNH 20-position terminal block is a separate accessory often required for installation, though it is compatible with the standard 96mm form factor.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding VFD Mechanical Brake Logic and Control in Industrial Automation

Understanding VFD Mechanical Brake Logic and Control in Industrial Automation

Variable Frequency Drives (VFDs) play a crucial role in modern industrial automation by controlling motor speed, torque, and acceleration. However, high-inertia loads and vertical lifting systems require precise mechanical braking logic to ensure operational safety and prevent equipment damage.

Read more
Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Industrial automation systems rely heavily on Programmable Logic Controllers (PLCs) to maintain uninterrupted production. When a PLC unexpectedly shifts from Run to Stop mode, whole manufacturing lines stall.

As control systems evolve across modern factory automation, understanding the root causes of these interruptions helps engineers minimize costly downtime. This technical guide breaks down why PLCs trip into Stop mode and provides practical strategies to mitigate system faults.

Read more
Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Modern Programmable Logic Controllers manage execution through distinct operational states: Run, Stop, Start-Up, and Hold. During power-up, a controller initializes memory registers within Stop mode before briefly transitioning to Start-Up mode. During this phase, internal self-diagnostics evaluate system integrity across hardware and user programs. If the controller detects no critical faults, it enters Run mode to execute the control program continuously. However, any severe system anomaly forces the CPU back into Stop mode immediately to prevent erratic machine behavior across the plant floor.

Read more