Skip to content

What are you looking for?


You may also like

Honeywell TC-OAH061 (96978274-A01) Isolated Analog Output Module 6-ChannelHoneywell TC-OAH061 (96978274-A01) Isolated Analog Output Module 6-ChannelHoneywell TC-OAH061 (96978274-A01) Isolated Analog Output Module 6-Channel
Honeywell TC-OAH061 (96978274-A01) Isolated Analog Output Module 6-Channel
Honeywell TC-OAH061 (96978274-A01) Isolated Analog Output Module 6-Channel
Honeywell TC-OAH061 (96978274-A01) Isolated Analog Output Module 6-Channel

Honeywell TC-OAH061 (96978274-A01) Isolated Analog Output Module 6-Channel


Only 10 left - Selling fast

PRODUCT SKU : TC-OAHO61

PRODUCT TYPE : Analog Output Module

PRODUCT VENDOR : Honeywell


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The TC-OAH061 (96978274-A01) is a high-performance analog interface module designed for precision control within Honeywell industrial systems. This unit provides six independent, galvanically isolated output channels capable of driving current loops up to 21.0 mA. With a 13-bit digital-to-analog conversion resolution, it ensures highly accurate modulation of field devices such as control valves and variable speed drives. The module is engineered for high-availability environments, featuring an impressive 2546 VDC isolation rating and robust RFI immunity to maintain signal integrity in electrically noisy industrial settings.

Technical Specifications

  • Module Identification: TC-OAH061

  • Associated Part Number: 96978274-A01

  • Channel Configuration: 6 Point, Galvanically Isolated

  • Output Signal Range: 0 to 21.0 mA

  • Digital Resolution: 13 bits across the full 21 mA span

  • Response Logic: 25 ms update rate for all concurrent channels

  • Isolation Rating: 2546 VDC (Channel-to-Channel and User-to-System)

  • Protection Circuitry: Continuous 24 VAC/VDC overvoltage protection

  • Interference Resistance: RFI immunity <2.0% error at 10 V/m (27-1000 MHz)

  • Thermal Management: Power dissipation maximum of 6.7 W

  • Operating Environment: -10°C to +60°C (14°F to 140°F)

  • Physical Dimensions: 96 mm x 96 mm x 48 mm

  • Net Weight: 0.5 kg (approx. 1.1 lbs)

  • Required Terminal Block: TC-TBNH (20-position)

Operational Application

The TC-OAH061 (96978274-A01) is typically deployed in process industries where high-density isolation is required to prevent ground loops and protect the central processing unit from field-side transients. Its fast 25 ms update rate makes it suitable for dynamic control loops requiring rapid adjustment of actuators or frequency converters.

Frequently Asked Questions

  • Does this module support voltage output modes?

    The TC-OAH061 is optimized for current loop signaling (0-21 mA). For 0-10V applications, a dedicated voltage output module or external precision resistor may be required.

  • Is the terminal block included with the module?

    The TC-TBNH 20-position terminal block is a separate accessory often required for installation, though it is compatible with the standard 96mm form factor.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
PLC vs. HMI: Distinguishing the Brain from the Interface in Industrial Automation

PLC vs. HMI: Distinguishing the Brain from the Interface in Industrial Automation

In the realm of industrial automation, distinguishing between a Programmable Logic Controller (PLC) and a Human-Machine Interface (HMI) is fundamental. While both devices work in tandem, they serve distinct purposes. The PLC acts as the "brain" of the operation, executing logic, whereas the HMI serves as the "eyes," allowing operators to monitor and interact with the system. Understanding this synergy is essential for any professional designing robust factory automation solutions.

Read more
Selecting the Right Industrial Automation Solution for Modern Manufacturing

Selecting the Right Industrial Automation Solution for Modern Manufacturing

Choosing an effective industrial automation system starts with a thorough process audit. You must identify tasks that are repetitive, labor-intensive, or prone to human error. Not every process requires high-level automation; therefore, prioritize operations that directly impact throughput and quality. By scoping your needs accurately, you avoid over-investing in unnecessary technology. A balanced approach ensures that your capital expenditure aligns with measurable gains in operational efficiency.

Read more
Implementing FIFO and LIFO Data Sequencing in PLC Programming

Implementing FIFO and LIFO Data Sequencing in PLC Programming

Data management serves as a cornerstone of modern industrial automation. Whether tracking materials on a conveyor or managing batch sequences in a process, engineers frequently rely on sequential logic. Two primary structures—First-In-First-Out (FIFO) and Last-In-First-Out (LIFO)—form the bedrock of this data handling. Mastering these blocks allows programmers to optimize complex machine operations efficiently.

Read more