Product Description

The TC-IDK161 (TK-IDK161) is a high-density discrete input interface engineered for Honeywell industrial control architectures. This module provides 16 individual sensing points designed to monitor 120 VAC field signals. A critical feature of this hardware is its total channel-to-channel isolation, which ensures that each input is electrically independent. This prevents ground loops and protects the controller backplane from field-side electrical transients, making it an essential component for high-reliability process environments.

Technical Specifications

  • Model Identification: TC-IDK161

  • Part Number: TK-IDK161

  • Input Configuration: 16 Individually Isolated Channels

  • Nominal Operating Voltage: 120 VAC

  • On-State Voltage Range: 79 to 132 VAC (47-63 Hz)

  • Off-State Threshold: 20 VAC (Maximum)

  • Input Impedance: 11 KΩ @ 60 Hz

  • Signal Response Time: Programmable Off-to-On (1ms/2ms) and On-to-Off (9ms/18ms)

  • Isolation Rating: 2546 VDC (Channel-to-Channel and User-to-System)

  • Power Dissipation: 4.9 W

  • Backplane Current Draw: 0.125A @ 5VDC / 0.003A @ 24VDC

  • Physical Weight: 0.2 kg

  • Required Interface: TC-TBCH 36-position terminal block

Application and System Integration

The TC-IDK161 (TK-IDK161) is typically deployed in motor control centers (MCCs) and power distribution monitoring where diverse AC signals must be sensed. Because each of the 16 points is isolated, engineers can wire inputs from different phases or power sources into the same module without risk of cross-talk or short circuits. This density significantly reduces the required footprint in the I/O cabinet while adhering to IEC Type 1+ input compatibility standards.

Frequently Asked Questions

  • How does the programmable filter time affect performance?

    The user can adjust the delay times to balance between high-speed signal capture and the rejection of electrical noise or contact bounce commonly found on AC limit switches.

  • Is the terminal block included with the module?

    The TC-TBCH 36-position block is the recommended connection interface and is usually sourced separately to facilitate pre-wiring of the control cabinet.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Importance of Safety Barriers in PLC and DCS Control Systems

Importance of Safety Barriers in PLC and DCS Control Systems

Process industries handle flammable gases and liquids, making electrical instrumentation a constant ignition risk. Engineers designing PLC and DCS networks must implement strict energy-limiting strategies. Intrinsic Safety barriers provide the critical interface that safeguards automation assets and prevents explosions.
Read more
Static UPS vs. Rotary UPS: Technical Evaluation for Industrial Automation

Static UPS vs. Rotary UPS: Technical Evaluation for Industrial Automation

UPS architecture dictates power reliability in process automation. Unplanned voltage sags cause immediate downtime, making robust power backup essential for PLC and DCS networks. This technical guide evaluates the operational principles, key architectures, and tradeoffs between Static and Dynamic Rotary UPS systems.
Read more
Comprehensive Guide to Noise Types in Industrial Automation and Electronics

Comprehensive Guide to Noise Types in Industrial Automation and Electronics

Signal integrity determines reliability in modern industrial automation. Unwanted electrical noise degrades sensor data, distorts 4-20 mA current loops, and drops fieldbus communications. Engineers working with PLC, DCS, and TSI systems must effectively mitigate these disturbances. This technical guide analyzes key internal and external noise sources affecting control systems.
Read more