PRODUCT SKU : 10106/2/1

PRODUCT TYPE : Digital Input Module

PRODUCT VENDOR : Honeywell


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The Honeywell 10106/2/1 Digital Input Module is a fail-safe, line-monitored unit designed for use in emergency shutdown (ESD), fire and gas detection (F&G), and interlock systems. It provides secure acquisition of digital signals from field devices such as switches, relays, and alarms, transmitting them reliably to the control system. With fast response times, strong isolation, and diagnostic LED indicators, this module is engineered for dependable operation in demanding industrial environments.

Key Features

  • Model Number: 10106/2/1

  • Type: Digital Input Module (fail-safe, line-monitored)

  • Channels: 16 independent digital inputs

  • Input Type: Dry contact or 24 VDC signals

  • Response Time: < 10 ms

  • Isolation Voltage: > 1500 V AC channel-to-channel

  • LED Indicators: Power, input status, fault diagnostics

  • Operating Temperature: –20 °C to +60 °C

  • Storage Temperature: –40 °C to +85 °C

  • Humidity Range: 5–95% RH, non-condensing

  • Power Supply: 24 VDC ±10%, ~5 W consumption

  • Mounting: DIN rail or rack installation

  • Dimensions: 25 × 140 × 191 mm

  • Weight: 0.2 kg

Application Scenarios

  • Emergency Shutdown Systems: Reliable signal acquisition for critical safety functions

  • Fire & Gas Detection: Integration of alarms and sensors for hazard monitoring

  • Interlock Systems: Ensures secure digital input handling in process safety applications

  • Industrial Automation: Suitable for petrochemical, energy, and manufacturing environments

FAQ

Q: How many input channels does the 10106/2/1 provide?  

A: It supports 16 independent digital input channels.

Q: What is the typical response time?  

A: Less than 10 milliseconds.

Q: What type of signals can be connected?  

A: Dry contact inputs or 24 VDC signals.

Q: How does it compare to the Honeywell 10101/2/1 module?  

A: The 10106/2/1 is optimized for ESD and F&G systems with line monitoring and diagnostic LEDs, while the 10101/2/1 focuses on standard fail-safe digital input handling.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Essential Motion Control Commands: A Practical Guide for Engineers

Essential Motion Control Commands: A Practical Guide for Engineers

Automation engineers often rely on precise position and speed control to drive modern factory machinery. Modern industrial systems, such as Programmable Logic Controllers (PLCs) and Distributed Control Systems (DCS), depend heavily on standardized motion instructions. Mastering these commands ensures operational safety, protects mechanical components, and optimizes cycle times across production lines.

Read more
The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

Implementing robust protection in hazardous industrial environments represents a fundamental safety requirement in factory automation. Process facilities often handle volatile gases, dusts, and chemical agents that pose significant combustion risks. Consequently, control system engineers must deploy energy-limiting interfaces to isolate safe-area control cabinets from hazardous-area field instrumentation. This article examines the function, selection, and electrical principles of intrinsic safety barriers within modern PLC and DCS networks.

Read more
Architectural Selection and Scale Classification of PLC Systems in Industrial Automation

Architectural Selection and Scale Classification of PLC Systems in Industrial Automation

Selecting the correct control platform represents a foundational engineering decision in factory automation. System designers must carefully balance technical parameters against long-term operational requirements when implementing a Programmable Logic Controller (PLC). This article examines the critical evaluation metrics, physical scale classifications, and operational architectures of modern control systems.

Read more