Product Details
The Honeywell FS-SICC-0001/L20, also cataloged as the FS-SICC-0001 System Interconnection Cable, operates as a dedicated hardware component for direct signal pass-through between Safety Manager I/O modules and Field Termination Assemblies (FTAs) within Honeywell Safety Manager architecture.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | FS-SICC-0001/L20 |
| Brand | Honeywell |
| Origin | USA |
| Weight | 2.0 kg (shipping weight) |
| Dimensions | Outer Diameter approx 9.93 mm x 20 m length |
| Operating Temp | -20 to +60 deg C |
| Power Consumption | Passive interconnect assembly (Zero internal power draw) |
| Cable Type | System Interconnection Cable |
| Cable Length | 20 m (indicated by /L20 suffix) |
| Connectors | 1x I/O module connector (end 1), 1x 20-pin FTA connector (end 2) |
| System Compatibility | Honeywell Safety Manager |
Process Control & DCS Signal Interconnection Characteristics
The FS-SICC-0001/L20 cable assembly incorporates channel-to-channel isolation principles to suppress signal cross-talk over long conduit runs. Routing field-side I/O signals across a 20 m distance, the shielded assembly maintains low-attenuation transmission for discrete safety logic and 4-20 mA HART loop protocol field wiring connections. The physical conductor matrix eliminates ground loops between central chassis backplanes and remote field termination racks.
Frequently Asked Questions
Q: Does the FS-SICC-0001/L20 cable support hot-swapping or live disconnect during controller operation?
A: Physical disconnection of the cable during live execution is permitted only in dual-redundant I/O configurations; disconnecting a single-channel cable severs real-time communication between the I/O module and its associated FTA.
Q: What grounding procedure is required for the cable shielding along a 20 m run?
A: The cable shield drain wire must be bonded to the central cabinet safety earth bar at a single termination point to prevent ground potential loops from inducing noise on low-voltage analog signals.
Field Installation Guidelines
- Routing and Bend Radius: Secure the 20 m cable inside dedicated low-voltage instrument raceways or cable trays. Maintain a minimum static bend radius of 60 mm to avoid internal conductor fatigue and shield degradation.
- Connector Alignment: Align the I/O module connector and the 20-pin FTA connector precisely before seating. Tighten all mechanical locking screws to establish a vibration-proof interface.
- Shield Termination: Crimp the shield drain wire with an insulated terminal ferrule and clamp it securely to the master enclosure grounding bar.
- Wiring Separation: Route the system interconnection cable along path channels separated by at least 30 cm from high-voltage AC power cables.
Additional Information
- 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
- 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
- 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
- Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
- Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
- Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.