Honeywell FC-SDOL-0424 | Digital Output ModuleHoneywell FC-SDOL-0424 | Digital Output ModuleHoneywell FC-SDOL-0424 | Digital Output Module
Honeywell FC-SDOL-0424 | Digital Output Module
Honeywell FC-SDOL-0424 | Digital Output Module
Honeywell FC-SDOL-0424 | Digital Output Module

Honeywell FC-SDOL-0424 | Digital Output Module


Only 10 left - Selling fast

PRODUCT SKU : FC-SDOL-0424

PRODUCT TYPE : Digital Output Module

PRODUCT VENDOR : Honeywell


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The FC-SDOL-0424 from Honeywell is a digital output module engineered for Safety Manager systems. It provides four solid-state output channels with integrated short-circuit protection, ensuring reliable signal transmission and safe operation in industrial environments. Compact in design, the module balances high performance with efficient space utilization.

Technical Specifications

  • Model Number: FC-SDOL-0424

  • Manufacturer: Honeywell

  • Product Type: Digital Output Module

  • Space Requirements: 4 TE, 3 HE (equivalent to 4 HP, 3U)

  • Power Requirements:

    • 5 VDC, 15 mA

    • 24 VDC internal, 50 mA

    • 24 VDC external, 15 mA (without output load)

  • Number of Output Channels: 4

  • Output Specification: 24 VDC solid-state source, short-circuit proof

  • Maximum Channel Current: 1 A

  • Maximum Total Module Load: 3.6 A (limited by module dissipation)

  • Maximum Load Inductance: 0.5 H

  • Maximum Load Capacitance: 1 μF

  • Overload Detection Threshold: >10 Ω

  • Cold Resistance Lamp Threshold: >20 Ω

  • Voltage Drop: <1.3 V at 1 A

  • Off Current: <0.1 mA

  • Current Sense Voltage Drop: <1 V at 1 A

  • WDG Input Current: 4 mA

  • Shipping Weight: 2 kg

Key Features

  • Solid-State Outputs: Four channels with short-circuit protection

  • Compact Design: Efficient use of rack space with 4 TE, 3 HE footprint

  • Reliable Performance: Stable operation under varying load conditions

  • Integrated Monitoring: Overload and current sense detection for enhanced safety

  • Industrial Durability: Built for continuous operation in demanding environments

Application Scenarios

The FC-SDOL-0424 is suitable for:

  • Safety Manager systems requiring digital output expansion

  • Process automation environments with high reliability demands

  • Power generation and petrochemical facilities needing robust output modules

  • Distributed control systems requiring compact digital output solutions

FAQ

Q: How many outputs does the module provide?  A: Four solid-state digital output channels.

Q: What is the maximum current per channel?  A: Each channel supports up to 1 A.

Q: Is the module short-circuit proof?  A: Yes, all outputs are protected against short circuits.

Comparison with Similar Models

  • FC-SDOL-0412: Digital output module with reduced load capacity.

  • FC-SDOL-0424: Enhanced design with four channels, short-circuit protection, and higher total load rating.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Safety Relays in Industrial Automation: Architecture, Operation, and Functional Safety

Understanding Safety Relays in Industrial Automation: Architecture, Operation, and Functional Safety

Standard electromechanical relays provide basic electrical isolation between low-voltage control circuits and high-power output loads. A traditional switching relay features a magnetic coil driving mechanical Common (COM), Normally-Open (NO), and Normally-Closed (NC) contacts. However, standard relays pose severe functional risks when deployed in critical safety interlock circuits. High current inrush or mechanical wear can weld contacts together permanently. If contact welding occurs in an emergency stop circuit, pressing the button fails to halt hazardous machinery movements. Consequently, global functional safety standards prohibit standard relays for critical machine guarding functions.

Read more
Mastering Wire Identification in Industrial Automation: The Power of Ferrules and Cross-Ferruling

Mastering Wire Identification in Industrial Automation: The Power of Ferrules and Cross-Ferruling

Proper wire labeling forms the cornerstone of reliable control system installation and long-term maintenance. In complex industrial automation environments, technicians terminate thousands of conductor ends inside control panels, marshalling racks, and field junction boxes. Ferrules serve as individual tube-shaped sleeve markers slipped onto conductors before final termination. While technicians historically relied on pre-printed individual letter rings, modern control panel builders utilize automated ferrule printing machines. These thermal-transfer printers generate durable, single-sleeve heat-shrink tags directly matching approved wiring schematics, significantly accelerating cabinet assembly workflows.

Read more
Understanding Marshalling Cabinets in Industrial Automation and Control Systems

Understanding Marshalling Cabinets in Industrial Automation and Control Systems

Marshalling cabinets serve as the crucial connection hub between field instruments and centralized processing units. In large DCS and PLC control system architectures, hundreds of multipair field cables run from local junction boxes to the central instrument equipment room. The marshalling cabinet houses field terminal blocks, surge arresters, intrinsic safety isolation barriers, and interposing relays. By segregating field field-wiring terminations from sensitive processor hardware, engineers protect expensive controller backplanes from high-voltage transients. Consequently, this modular separation dramatically streamlines maintenance workflows and simplifies system expansion.

Read more