Skip to content

What are you looking for?


You may also like

Honeywell Experion PKS MC-TAIH12 High Level Analog Input ModuleHoneywell Experion PKS MC-TAIH12 High Level Analog Input ModuleHoneywell Experion PKS MC-TAIH12 High Level Analog Input Module
Honeywell Experion PKS MC-TAIH12 High Level Analog Input Module
Honeywell Experion PKS MC-TAIH12 High Level Analog Input Module
Honeywell Experion PKS MC-TAIH12 High Level Analog Input Module

Honeywell Experion PKS MC-TAIH12 High Level Analog Input Module


Only 10 left - Selling fast

PRODUCT SKU : MC-TAIH12 51304337-150

PRODUCT TYPE : Analog Input Module

PRODUCT VENDOR : Honeywell


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The MC-TAIH12 is a specialized High Level Analog Input (HLAI) termination assembly designed for the Honeywell Experion PKS and TDC 3000 control environments. This module facilitates the integration of field signals into the controller backbone, specifically handling high-level voltage and current inputs with precision and high noise immunity.

Engineered for 12-channel operation, the assembly provides a secure physical interface for field wiring, ensuring signal integrity through advanced conditioning circuits. Its robust construction is tailored for continuous operation in mission-critical process industries where downtime is not an option.

Technical Specifications

  • Model Number: MC-TAIH12

  • Brand: Honeywell

  • Product Series: Experion PKS / TDC 3000

  • Input Channels: 12 High-Level Analog Inputs

  • Input Signal Types: 1-5 VDC, 4-20 mA (with appropriate shunt resistors)

  • Physical Dimensions: 24 cm x 25 cm x 6.4 cm

  • Net Weight: 1.0 kg

  • Coating: Conformal coating available for harsh environment protection

  • Termination Type: Screw terminal blocks for field wiring

  • System Interface: Compatible with High Level Analog Input Processors (HLAIP)

Operational Applications

This module is typically deployed in centralized control rooms or remote instrument enclosures within oil refineries, chemical plants, and utility power stations. It is used to monitor critical process variables such as pressure, temperature, and flow rate sensors that output high-level standard signals.

Technical FAQ

  • Does the MC-TAIH12 support redundancy?

    Yes, this termination assembly is fully compatible with redundant I/O processor configurations to ensure high system availability.

  • What is the primary difference between MC and MU series versions?

    The MC-TAIH12 usually denotes a version with conformal coating (MC) for protection against corrosive atmospheres, whereas the MU series is typically non-coated.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Importance of Safety Barriers in PLC and DCS Control Systems

Importance of Safety Barriers in PLC and DCS Control Systems

Process industries handle flammable gases and liquids, making electrical instrumentation a constant ignition risk. Engineers designing PLC and DCS networks must implement strict energy-limiting strategies. Intrinsic Safety barriers provide the critical interface that safeguards automation assets and prevents explosions.
Read more
Static UPS vs. Rotary UPS: Technical Evaluation for Industrial Automation

Static UPS vs. Rotary UPS: Technical Evaluation for Industrial Automation

UPS architecture dictates power reliability in process automation. Unplanned voltage sags cause immediate downtime, making robust power backup essential for PLC and DCS networks. This technical guide evaluates the operational principles, key architectures, and tradeoffs between Static and Dynamic Rotary UPS systems.
Read more
Comprehensive Guide to Noise Types in Industrial Automation and Electronics

Comprehensive Guide to Noise Types in Industrial Automation and Electronics

Signal integrity determines reliability in modern industrial automation. Unwanted electrical noise degrades sensor data, distorts 4-20 mA current loops, and drops fieldbus communications. Engineers working with PLC, DCS, and TSI systems must effectively mitigate these disturbances. This technical guide analyzes key internal and external noise sources affecting control systems.
Read more