Only 10 left - Selling fast

PRODUCT SKU : 80363969-100

PRODUCT TYPE : Analog Output Modules

PRODUCT VENDOR : Honeywell


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The Honeywell 80363969-100, also cataloged as the 80363969-100 Analog Output Processor Module, operates as a dedicated hardware component for converting digital control signals to analog outputs within Honeywell TDC 3000 and Process Manager architectures. It drives 16 isolated channels outputting 4-20 mA analog current directly to field positioning devices and analog control loops.

Hardware Specifications

Parameter Specification
Model 80363969-100
Brand Honeywell
Origin USA
Weight 1.0 kg
Dimensions 40 mm x 260 mm x 220 mm
Operating Temp 0 deg C to 60 deg C
Power Consumption Standard Backplane Load
Output Channels 16 isolated channels
Output Range 4-20 mA analog current
Compatible Terminal Boards MU-TAOY22, MU-TAOY52, MC-TAOY22, MC-TAOY52

Channel-to-Channel Isolation and Loop Protocol Response

The Honeywell 80363969-100 incorporates internal optical decoupling across all 16 current loops to maintain channel-to-channel isolation. This galvanic barrier protects internal microprocessor logic against field ground loops and high-voltage electrical surges. When operating with 4-20 mA HART loop protocol field positioners, the digital-to-analog converter stage provides continuous loop impedance management to stabilize signal conversion over extended cable distances.

Frequently Asked Questions

Q: Are terminal connections made directly to the front face of the 80363969-100 module?

A: No. Field cabling connects to compatible external terminal assemblies such as the MU-TAOY22, MU-TAOY52, MC-TAOY22, or MC-TAOY52, which link to the module via dedicated multi-conductor cables.

Q: Can an individual 4-20 mA output channel be configured as a voltage output?

A: No. The internal digital-to-analog conversion circuitry is designed strictly for 4-20 mA current loop driving and does not provide native voltage output options.

Field Installation Guidelines

  1. Turn off main rack power and field loop power supplies prior to seating or removing the module from the chassis slot.
  2. Align the module circuit board with the chassis card guides and push firmly until the rear connectors seat securely into the backplane.
  3. Fasten the module retaining screws to ensure proper chassis grounding and mechanical retention under operational vibration.
  4. Route field signal cables through grounded, shielded conduits and separate them from high-voltage AC power wiring to prevent noise coupling.
  5. Verify that shield drain wires are tied to a single-point system ground block at the cabinet cable entrance.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Static UPS vs. Rotary UPS: Technical Evaluation for Industrial Automation

Static UPS vs. Rotary UPS: Technical Evaluation for Industrial Automation

UPS architecture dictates power reliability in process automation. Unplanned voltage sags cause immediate downtime, making robust power backup essential for PLC and DCS networks. This technical guide evaluates the operational principles, key architectures, and tradeoffs between Static and Dynamic Rotary UPS systems.
Read more
Comprehensive Guide to Noise Types in Industrial Automation and Electronics

Comprehensive Guide to Noise Types in Industrial Automation and Electronics

Signal integrity determines reliability in modern industrial automation. Unwanted electrical noise degrades sensor data, distorts 4-20 mA current loops, and drops fieldbus communications. Engineers working with PLC, DCS, and TSI systems must effectively mitigate these disturbances. This technical guide analyzes key internal and external noise sources affecting control systems.
Read more
Mitigating Emergency Stop Spurious Trips in Industrial Control Systems

Mitigating Emergency Stop Spurious Trips in Industrial Control Systems

Emergency stop (E-Stop) pushbuttons serve as vital safety devices in factory automation and process control plants. Functional safety standards mandate normally-closed (NC) contact blocks to ensure fail-safe operation during wiring breaks or power outages. However, mechanical degradation over time can trigger unexpected spurious trips, halting production lines without an actual emergency. Understanding the underlying causes of mechanical contact failure allows automation engineers to implement robust, fault-tolerant safety circuits.

Read more