Skip to content

What are you looking for?


You may also like

Honeywell 51401570-100 PWB Keyboard Interface BoardHoneywell 51401570-100 PWB Keyboard Interface BoardHoneywell 51401570-100 PWB Keyboard Interface Board
Honeywell 51401570-100 PWB Keyboard Interface Board
Honeywell 51401570-100 PWB Keyboard Interface Board
Honeywell 51401570-100 PWB Keyboard Interface Board

Honeywell 51401570-100 PWB Keyboard Interface Board


Only 10 left - Selling fast

PRODUCT SKU : 51401570-100

PRODUCT TYPE : Interface Modules

PRODUCT VENDOR : Honeywell


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The Honeywell 51401570-100, also cataloged as the 51400972-100 PWB Keyboard Interface Board, operates as a dedicated hardware component for key-matrix decoding and operator station input processing within TDC 3000 console terminals.

Hardware Specifications

Parameter Specification
Model 51401570-100
Brand Honeywell
Origin USA
Weight 1.74 lbs (0.79 kg)
Dimensions Standard operator console PWB form factor
Operating Temp 0 to 60 deg C
Power Consumption 5 VDC internal bus supply
Part Number 51401570-100 (Replaces 51400972-100)
Layout Compatibility ABCDE and QWERTY key matrices

Channel-to-Channel Isolation & Console Signal Integration

The printed wiring board converts physical key closures into deterministic binary scan codes for the main operator station processor. Built-in signal suppression circuits prevent keystroke chatter and electrical noise from interfering with nearby 4-20 mA HART loop diagnostic buses or analog console displays. Optocoupled control pathways isolate key-matrix scan loops from central chassis ground reference planes, protecting signal integrity during continuous operation.

Frequently Asked Questions

Q: Is the 51401570-100 backwards compatible with older 51400972-100 board revisions?

A: Yes, part number 51401570-100 serves as a direct form, fit, and functional replacement for former part number 51400972-100 across both ABCDE and QWERTY operator keyboards.

Q: Can this interface board be hot-swapped while the operator station is fully powered?

A: Hot-swapping is not recommended; power to the operator keyboard housing or node chassis should be isolated before unseating or inserting signal ribbon cables.

Q: How does the board interface handle simultaneous key presses?

A: The onboard scanning logic executes hardware anti-ghosting and debouncing protocols to correctly register individual keystrokes without transmission errors.

Field Installation Guidelines

  1. Disconnect main power to the operator console enclosure before servicing internal circuit boards.
  2. Utilize a grounded wrist strap attached to chassis earth ground to prevent electrostatic discharge (ESD) during handling.
  3. Align the PWB mounting holes with the standoffs inside the keyboard assembly and tighten retaining hardware evenly.
  4. Carefully seat all multi-pin ribbon cables onto the board connectors, verifying proper pin-1 alignment and clip engagement.
  5. Restore system power and execute standard operator key-matrix diagnostic tests to verify functional registration across all keys.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
PLC and DCS Control System Spares Strategy: Engineering Guidelines

PLC and DCS Control System Spares Strategy: Engineering Guidelines

Modern factory automation relies on high-speed fiber optic backbones to link distributed control systems across noise-intensive industrial environments. Unlike copper wiring, optical fibers transmit data via light pulses, making them completely immune to electromagnetic interference (EMI). Field engineers must master optical cable joining and fusion splicing techniques to guarantee low-loss data transmission across critical Programmable Logic Controller (PLC) and Distributed Control System (DCS) nodes.

Read more
PLC and DCS Control System Spares Strategy: Engineering Guidelines

PLC and DCS Control System Spares Strategy: Engineering Guidelines

Industrial automation lifecycle management requires robust spare parts planning for Programmable Logic Controller (PLC) and Distributed Control System (DCS) platforms. Plant engineers must correctly categorize spare components during front-end engineering design to maintain high system availability. Miscalculating spare requirements can lead to prolonged unscheduled downtime, project budget overruns, or delayed site commissioning.

Read more
Wellhead Control Panel (WHCP) Architecture in Oil and Gas Automation

Wellhead Control Panel (WHCP) Architecture in Oil and Gas Automation

Upstream oil and gas operations rely on specialized field control platforms to manage wellhead extraction safety and hydraulic actuation. A Wellhead Control Panel (WHCP) serves as a dedicated hydraulic and pneumatic power unit designed to operate critical Christmas Tree isolation valves. By interfacing field safety components directly with Programmable Logic Controller (PLC) architecture, a WHCP protects upstream extraction assets against overpressure, catastrophic leaks, and thermal emergencies.

Read more