Skip to content

What are you looking for?


You may also like

Honeywell 51202335-100 Series C Communication Cable ControllerHoneywell 51202335-100 Series C Communication Cable ControllerHoneywell 51202335-100 Series C Communication Cable Controller
Honeywell 51202335-100 Series C Communication Cable Controller
Honeywell 51202335-100 Series C Communication Cable Controller
Honeywell 51202335-100 Series C Communication Cable Controller

Honeywell 51202335-100 Series C Communication Cable Controller


Only 10 left - Selling fast

PRODUCT SKU : 51202335-100

PRODUCT TYPE : Communication Modules

PRODUCT VENDOR : Honeywell


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The Honeywell 51202335-100, also cataloged as the 51202335-100 Communication Cable Controller, operates as a dedicated hardware component for serial data bus management and physical signal routing within Honeywell C300 and Series C systems. Designed to manage RS-485 network physical layers, the module accepts an operating voltage of 120 VAC at 60 Hz with a continuous current rating of 10 A. The unit is housed in an IP65 enclosure measuring 94 mm x 140 mm x 89 mm, processing differential RS-485 communication lines to execute multi-drop node synchronization across industrial controller backplanes.

Hardware Specifications

Parameter Specification
Model 51202325-100
Brand Honeywell
Origin USA
Weight 0.50 kg
Dimensions 94 mm x 140 mm x 89 mm
Operating Temp -40 to +70 deg C
Power Consumption 120 VAC, 60 Hz, 10 A current rating
Communication Interface RS-485 serial interface
Ingress Protection IP65
Storage Temp -55 to +85 deg C
System Platform Honeywell C300 / Series C Systems

4-20 mA HART Loop Protocol & Channel-to-Channel Isolation

The 51202335-100 incorporates optoelectronic line isolation between the high-power 120 VAC main supply rails and low-voltage RS-485 communication differential transceivers. When installed alongside analog instrument buses processing 4-20 mA HART loop protocol signals, the internal shielding suppresses common-mode voltage spikes and high-frequency noise. This isolation scheme preserves channel-to-channel isolation parameters and prevents ground potential differences across field cable runs from disturbing serial controller data transmission.

Frequently Asked Questions

Q: Can the RS-485 communication lines be connected or disconnected while the 120 VAC supply is active?

A: High-voltage wiring must be completely isolated before servicing terminals; however, the optically isolated RS-485 communication channels can be reconfigured if proper ground potential equalization is maintained.

Q: What termination impedance is required for the RS-485 bus managed by this cable controller?

A: Standard 120 ohm line-termination resistors should be applied at the physical end nodes of the RS-485 differential pair to prevent signal reflection across high-speed data runs.

Field Installation Guidelines

  1. Mount the IP65 enclosure securely onto the cabinet DIN-rail or mounting plate using the provided hardware points.
  2. Connect 120 VAC power leads to the designated power terminals, ensuring line, neutral, and frame earth conductors are wired correctly.
  3. Terminate RS-485 differential data cables using shielded twisted-pair conductors, bonding the cable shield braid to cabinet ground at a single point.
  4. Route high-voltage AC lines in separate wireways from RS-485 data paths to maintain signal fidelity and minimize noise coupling.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
The Shift to Flexible IO Modules in Modern Industrial Automation

The Shift to Flexible IO Modules in Modern Industrial Automation

Traditional control systems rely on dedicated Input Output (IO) cards for industrial automation. Each conventional module processes a single signal type, such as Digital Input (DI), Digital Output (DO), Analog Input (AI), or Analog Output (AO). A standard 16-channel card accepts only one specific channel type across all ports. This inflexible hardware design often creates severe engineering bottlenecks during project execution. Engineers frequently must install entirely new cards to accommodate a single extra sensor. Consequently, late design changes increase control cabinet space requirements and drive up project costs.

Read more
DCS Commissioning Steps in Industrial Automation Projects

DCS Commissioning Steps in Industrial Automation Projects

Commissioning a Distributed Control System (DCS) represents a crucial milestone when deploying modern process automation infrastructure. Field engineers must execute systematic verification steps to transition complex control hardware from static installation to dynamic plant control. Proper commissioning ensures that controllers, I/O modules, network switches, and HMI software operate in strict compliance with engineering design specifications before introducing live process fluids.

Read more
PLC and DCS Control System Spares Strategy: Engineering Guidelines

PLC and DCS Control System Spares Strategy: Engineering Guidelines

Modern factory automation relies on high-speed fiber optic backbones to link distributed control systems across noise-intensive industrial environments. Unlike copper wiring, optical fibers transmit data via light pulses, making them completely immune to electromagnetic interference (EMI). Field engineers must master optical cable joining and fusion splicing techniques to guarantee low-loss data transmission across critical Programmable Logic Controller (PLC) and Distributed Control System (DCS) nodes.

Read more