Product Details

Technical Overview

The HIMA F 6217 is a high-precision, safety-related analog input module engineered for the HIMatrix F and M series controllers. This 8-fold module is designed to interface with critical sensors in environments requiring up to SIL 3 certification. It features integrated safety isolation and supports both current and voltage signals, providing the rapid response times essential for emergency shutdown (ESD) and high-pressure protection (HIPPS) applications.

Detailed Specifications

  • Module Type: 8-Channel Analog Input (Safety-Related)

  • Safety Integrity Level: SIL 3 / AK6 / PLe

  • Input Range (Current): 0/4...20 mA (utilizing an external or internal shunt)

  • Input Range (Voltage): 0...5 V / 0...10 V DC

  • A/D Resolution: 12-Bit

  • Input Impedance: 100 kΩ

  • Measurement Scaling: 0 mV = 0 units | 5.5 V = 4095 units

  • Maximum Input Limits: 5.5 V (Voltage) / 22 mA (Current)

  • Galvanic Isolation: Safety-isolated channels for interference suppression

  • Form Factor: Compact module for HIMatrix rail-mounting

Configuration and Compatibility

The F6217/F 6217 (Part Number: F6217) is programmed and configured via the HIMA SILworX engineering tool. It is often utilized in distributed I/O architectures where analog process variables (pressure, temperature, flow) must be monitored with high reliability.

Frequently Asked Questions

How does the F 6217 handle current signals if it is a voltage-based input?The module measures voltage drops across a shunt resistor. When monitoring 0/4...20 mA loops, a shunt is applied to convert the current to a proportional voltage within the 0...5.5 V range.

Can the F 6217 be used in non-safety applications?While designed for SIL 3 safety loops, it can process standard control signals; however, its primary value lies in its diagnostic capabilities and failure-safe architecture.

Product Comparison

  • F 6217: 8-fold Analog Input, 12-bit resolution, versatile current/voltage support.

  • F 6214: 4-fold Analog Input, typically used for smaller-scale signal monitoring.

  • F 6221: High-density Digital Input module, used for discrete states rather than analog variables.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
PLC vs. HMI: Distinguishing the Brain from the Interface in Industrial Automation

PLC vs. HMI: Distinguishing the Brain from the Interface in Industrial Automation

In the realm of industrial automation, distinguishing between a Programmable Logic Controller (PLC) and a Human-Machine Interface (HMI) is fundamental. While both devices work in tandem, they serve distinct purposes. The PLC acts as the "brain" of the operation, executing logic, whereas the HMI serves as the "eyes," allowing operators to monitor and interact with the system. Understanding this synergy is essential for any professional designing robust factory automation solutions.

Read more
Selecting the Right Industrial Automation Solution for Modern Manufacturing

Selecting the Right Industrial Automation Solution for Modern Manufacturing

Choosing an effective industrial automation system starts with a thorough process audit. You must identify tasks that are repetitive, labor-intensive, or prone to human error. Not every process requires high-level automation; therefore, prioritize operations that directly impact throughput and quality. By scoping your needs accurately, you avoid over-investing in unnecessary technology. A balanced approach ensures that your capital expenditure aligns with measurable gains in operational efficiency.

Read more
Implementing FIFO and LIFO Data Sequencing in PLC Programming

Implementing FIFO and LIFO Data Sequencing in PLC Programming

Data management serves as a cornerstone of modern industrial automation. Whether tracking materials on a conveyor or managing batch sequences in a process, engineers frequently rely on sequential logic. Two primary structures—First-In-First-Out (FIFO) and Last-In-First-Out (LIFO)—form the bedrock of this data handling. Mastering these blocks allows programmers to optimize complex machine operations efficiently.

Read more