Skip to content

What are you looking for?


You may also like

GE IS200EAUXH1AAA TMR Auxiliary Function ModuleGE IS200EAUXH1AAA TMR Auxiliary Function ModuleGE IS200EAUXH1AAA TMR Auxiliary Function Module
GE IS200EAUXH1AAA TMR Auxiliary Function Module
GE IS200EAUXH1AAA TMR Auxiliary Function Module
GE IS200EAUXH1AAA TMR Auxiliary Function Module

GE IS200EAUXH1AAA TMR Auxiliary Function Module


Only 10 left - Selling fast

PRODUCT SKU : IS200EAUXH1AAA

PRODUCT TYPE : I/O Interface Modules

PRODUCT VENDOR : General Electric


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Configured for auxiliary I/O interfacing in EX2100E excitation control systems, the GE IS200EAUXH1AAA (IS200EAUXH1) TMR Auxiliary Function Module provides direct physical/electrical execution.

Hardware Specifications

Parameter Specification
Model IS200EAUXH1AAA
Brand GE
Origin USA
Weight Approximately 1.81 kg
Component Configuration 7 relays, 8 jumpers (J1-J8)

Industrial Control and Drives Characteristics

The IS200EAUXH1AAA functions as an Exciter Auxiliary I/O Interface Board within the EX2100E excitation control architecture. The module design incorporates a series of jumpers (J1-J8) to facilitate hardware-level configuration and seven onboard relays for discrete switching operations. Deterministic network performance within the EX2100E system relies on the integrity of this module's signal paths, which interface with the controller backplane to manage auxiliary I/O requirements. The PCB features conformal coating to enhance durability against environmental contaminants in industrial conditions. I/O density scaling and firmware flash compatibility are maintained through the module's integration with the primary control processors, ensuring that auxiliary functions are synchronized with the main excitation control loops.

Frequently Asked Questions

Q: Does the IS200EAUXH1AAA support hot-swapping?

A: No. Due to its role in the auxiliary I/O interface and the presence of relay-driven control circuits, the module must not be removed or inserted while the EX2100E system is energized. De-energize the associated power circuits prior to any maintenance activity.

Q: How should the jumper settings (J1-J8) be configured during replacement?

A: Jumper settings must match the configuration of the original board exactly. Before removing the existing module, document the position of each jumper (J1-J8) and replicate this configuration on the replacement unit to ensure compatibility with the existing control logic and I/O assignments.

Field Installation Guidelines

  • Static Protection: Use an ESD-safe workstation and wrist strap when handling the IS200EAUXH1AAA to protect sensitive onboard components and the identification device.
  • Mechanical Installation: Secure the board using the pre-drilled mounting holes. Ensure that the module is firmly seated to prevent vibration-induced loosening, which may impact the relay and jumper connection integrity.
  • Visual Inspection: Conduct a pre-installation inspection to verify that no jumpers were displaced during shipping and that all relay seating is correct.
  • Cable Management: Ensure that field wiring connected to the module is supported by strain relief mechanisms to prevent physical stress on the board’s termination points.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Redundant Automation Systems: Ensuring Continuous Uptime in Critical Control Infrastructure

Redundant Automation Systems: Ensuring Continuous Uptime in Critical Control Infrastructure

System reliability directly determines operational profitability across high stakes process industries. Modern industrial automation platforms must eliminate single points of failure to prevent catastrophic shutdowns. Deploying fault tolerant architecture safeguards complex facilities against unexpected hardware glitches, network disruptions, and maintenance outages.

Read more
Understanding Types of Noise in Electronic Circuits and Control Systems

Understanding Types of Noise in Electronic Circuits and Control Systems

Signal integrity directly determines measurement accuracy and loop stability across industrial automation environments. Electronic noise introduces unwanted stochastic interference into analog loops, sensor feedback lines, and digital fieldbus networks. Understanding how intrinsic electronic noise and external electromagnetic interference manifest allows control engineers to optimize signal conditioning and shield sensitive instrumentation effectively.

Read more
Why 24V DC Power Supplies Standardize Modern Industrial Automation

Why 24V DC Power Supplies Standardize Modern Industrial Automation

Industrial control cabinets worldwide rely on 24V DC as the universal power standard for field instrumentation, sensors, and controllers. Walk into any manufacturing plant, and you will find PLCs, human-machine interfaces (HMIs), and smart actuators running on extra-low voltage DC. Standardizing on 24V DC enhances operational safety, lowers cabinet footprint, and maintains steady control performance across factory networks.

Read more