The Foxboro P0916MZ, also cataloged as the P0916MZ Interface Cable, operates as a dedicated hardware component for 2 Mbps high-speed data transmission between local modules and P0940XA or P0940XB bus couplers within I/A Series platforms.

Hardware Specifications

Parameter Specification
Model P0916MZ
Brand Foxboro
Origin USA
Weight 0.12 kg (0.26 lbs)
Dimensions Length 1.0 m
Transmission Rate 2 Mbps Serial Bus
Compatible Hardware P0940XA / P0940XB Bus Couplers
Operating Temp -20 to +70 deg C
Power Consumption Passive (0 W)

Channel-to-Channel Isolation & Signal Integrity

The Foxboro P0916MZ interface cable provides high-frequency noise immunity for 2 Mbps deterministic fieldbus communication streams. Designed with optimized characteristic impedance and full-coverage shield construction, the assembly mitigates high-frequency signal attenuation and suppresses cross-talk between high-speed serial pairs. It maintains physical channel-to-channel isolation and signal ground reference integrity between connected I/A Series modules and P0940XA or P0940XB coupling units.

Frequently Asked Questions

Q: Can the Foxboro P0916MZ cable be disconnected or connected while the baseplate network is live?

A: Yes, the cable carries low-voltage passive bus signals, enabling hot-plug capability at the connector level without causing backplane power disruption.

Q: Is 2 Mbps the maximum rated data transfer speed for the P0916MZ cable assembly?

A: Yes, the internal wire pair twisting and impedance matching are specified for deterministic 2 Mbps serial fieldbus throughput to P0940XA/B modules.

Field Installation Guidelines

  1. Inspect cable pin connectors for physical alignment and clean contact pins before joining with module headers.
  2. Maintain a minimum bend radius of 75 mm throughout the cable routing to avoid conductor strain and differential impedance shifts.
  3. Route the 1.0 m cable through dedicated low-voltage wire ducts, maintaining a minimum 300 mm clearance from high-voltage AC lines.
  4. Fully seat connector housings into the P0940XA or P0940XB receptacles, tightening retention screws hand-tight.
  5. Ensure shield drain connections link directly to cabinet ground terminals following single-point grounding rules.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Managed Switch vs. Unmanaged Switch: Industrial Ethernet Architecture

Managed Switch vs. Unmanaged Switch: Industrial Ethernet Architecture

Industrial Ethernet forms the backbone of factory automation. Selecting the right switch architecture determines system uptime, data throughput, and OT cyber resilience. This technical guide evaluates managed vs. unmanaged switches, analyzing operational differences, security controls, and selection criteria.
Read more
Hot Standby vs. Cold Standby Redundancy in Industrial Automation

Hot Standby vs. Cold Standby Redundancy in Industrial Automation

System availability determines process safety and productivity in industrial automation. Control engineers deploy redundancy to eliminate single points of failure. This technical guide evaluates Hot Standby vs. Cold Standby architectures, comparing failover speeds, memory sync, cost trade-offs, and field selection criteria.

Read more
ON-OFF Controller vs. PID Controller: Industrial Control System Evaluation

ON-OFF Controller vs. PID Controller: Industrial Control System Evaluation

Selecting the right control strategy impacts process stability, efficiency, and equipment lifespan. This technical comparison evaluates binary ON-OFF and continuous PID control algorithms, analyzing their mathematical behavior, operational differences, and practical selection criteria for factory automation.
Read more