Skip to content

What are you looking for?


You may also like

Foxboro FBM216B P0927AJ I/A Series Redundant HART Input Interface ModuleFoxboro FBM216B P0927AJ I/A Series Redundant HART Input Interface ModuleFoxboro FBM216B P0927AJ I/A Series Redundant HART Input Interface Module
Foxboro FBM216B P0927AJ I/A Series Redundant HART Input Interface Module
Foxboro FBM216B P0927AJ I/A Series Redundant HART Input Interface Module
Foxboro FBM216B P0927AJ I/A Series Redundant HART Input Interface Module

Foxboro FBM216B P0927AJ I/A Series Redundant HART Input Interface Module


Only 10 left - Selling fast

PRODUCT SKU : FBM216B P0927AJ

PRODUCT TYPE : HART Communication Module

PRODUCT VENDOR : Foxboro


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The Foxboro FBM216B (P0927AJ) functions as a high-integrity HART communication input interface for the Foxboro I/A Series Distributed Control System (DCS). This module processes eight individually isolated channels, managing both standard 4-20 mA analog signals and digital HART Frequency Shift Keying (FSK) data. It serves as a critical bridge for smart field instrumentation in refineries, chemical plants, and power utilities. We supply this hardware as 100% Brand New and Original, ensuring your control architecture utilizes factory-sealed components for maximum Mean Time Between Failures (MTBF).

Technical Specifications

Parameter Specification Detail
Manufacturer Foxboro (Schneider Electric)
Model Number FBM216B / P0927AJ
Channel Count 8 Individually Isolated Channels
Resolution 15 bits
Update Rate 100 ms per channel
Common Mode Rejection >100 dB at 50/60 Hz
Input Signal 4-20 mA with Superimposed Digital HART
Communication Speed 2 digital messages per second from field devices
Operating Temperature -40 to +70°C (-40 to +158°F)
Power Consumption Max 7 W (4 W Heat Dissipation)
Dimensions 4.5 cm (W) x 11 cm (H) x 11.5 cm (D)
Weight 0.32 kg

Engineering Advantages

The FBM216B P0927AJ overcomes specific signal integrity and system availability challenges through advanced hardware engineering:

  • Continuous Master-Tracker Redundancy: The module utilizes a redundant pair configuration with a common termination assembly. The "Tracker" module continuously monitors the "Master" module’s health and data. This architecture ensures an instantaneous switchover in the event of a hardware fault, preventing process interruptions.

  • Superior Noise Immunity: With a common mode rejection ratio exceeding 100 dB at 50/60 Hz, the FBM216B filters out heavy electrical noise typical of environments with large motors and variable frequency drives (VFDs). This ensures the DCS receives clean, accurate analog data.

  • High-Precision Signal Conversion: The 15-bit resolution and a low temperature coefficient (50 PPM/°C) provide ultra-stable measurements across the entire operating temperature range. This precision minimizes signal drift, reducing the frequency of field instrument recalibration.

  • Ruggedized Environmental Resilience: Unlike standard commercial I/O, the FBM216B operates reliably from -40°C to +70°C. It withstands vibrations up to 7.5 m/s², making it suitable for mounting in non-climate-controlled cabinets near heavy industrial machinery.

  • Isolated Field Protection: Every channel features independent galvanic isolation. This protection prevents ground loops and ensures that a high-voltage surge on one field loop does not propagate to the other seven channels or the system Fieldbus.

FAQs

  • Is the FBM216B P0927AJ compatible with existing I/A Series Fieldbus?

    Yes. The module interfaces with the redundant 2 Mbps Fieldbus and accepts communication from either the A or B path. It integrates seamlessly with existing FCM or FCP processors.

  • Does the module require external calibration?

    No. The factory calibrates the FBM216B to strict standards before sealing. The internal 15-bit architecture maintains high accuracy without the need for manual field adjustments, though we recommend standard loop checks during commissioning.

  • Can I use this module for non-HART 4-20 mA transmitters?

    Absolutely. The FBM216B treats standard 4-20 mA signals with the same 15-bit precision. It simply ignores the FSK digital layer if no HART data exists, providing high-speed analog updates (100 ms) for all channels.

  • How do I verify the hardware condition?

    We guarantee every FBM216B is 100% Brand New. Each unit ships in original Foxboro factory packaging with intact security seals, ensuring the hardware has never experienced thermal stress or field exposure.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Modern manufacturing relies heavily on automated control systems to maximize throughput and maintain product quality. However, unplanned downtime in industrial automation can cost facility operators thousands of dollars per hour. Understanding how programmable logic controllers (PLCs), distributed control systems (DCS), and field instrumentation fail empowers engineering teams to implement robust preventive maintenance strategies.

Read more
Essential Motion Control Commands: A Practical Guide for Engineers

Essential Motion Control Commands: A Practical Guide for Engineers

Automation engineers often rely on precise position and speed control to drive modern factory machinery. Modern industrial systems, such as Programmable Logic Controllers (PLCs) and Distributed Control Systems (DCS), depend heavily on standardized motion instructions. Mastering these commands ensures operational safety, protects mechanical components, and optimizes cycle times across production lines.

Read more
The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

Implementing robust protection in hazardous industrial environments represents a fundamental safety requirement in factory automation. Process facilities often handle volatile gases, dusts, and chemical agents that pose significant combustion risks. Consequently, control system engineers must deploy energy-limiting interfaces to isolate safe-area control cabinets from hazardous-area field instrumentation. This article examines the function, selection, and electrical principles of intrinsic safety barriers within modern PLC and DCS networks.

Read more