PRODUCT VENDOR : EMERSON


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Configured for high-speed process execution in Ovation OCR 1100 platforms, the Emerson 5X00481G01 (5X00481G01) provides direct physical execution of logic control and automation tasks utilizing an Atom CPU architecture.

Hardware Specifications

Parameter Specification
Model 5X00481G01
Brand Emerson
Origin Manufacturer-defined
Weight 2.5 kg
Dimensions 220 mm x 200 mm x 80 mm
Operating Temp -40 deg C to 70 deg C
Power Consumption < 25 W
Processor Atom CPU
Memory 1 GB DDR3

4-20 mA HART Loop Protocol

The 5X00481G01 module functions as the central processing unit for the Ovation OCR 1100 controller node. It handles the deterministic scan cycles required for field instrument data, including support for 4-20 mA HART loop protocol communications when interfaced with appropriate analog I/O modules. The CPU manages real-time logic execution, historical data logging, and communication with the Ovation backplane bus. Its internal architecture ensures high-speed data throughput for I/O scanning and process variable calculation. The design maintains strict synchronization with system-wide timing, facilitating seamless data exchange across the DCS network while maintaining environmental resilience for industrial deployments.

Frequently Asked Questions

Q: Does the 5X00481G01 support firmware flash compatibility with legacy controller nodes?

A: Compatibility with specific controller series depends on the current system-wide firmware revision. Ensure that the controller firmware is updated to a compatible version before attempting to replace an existing node CPU to prevent communication mismatches on the DCS network.

Q: Are there specific power supply requirements for the 24 VDC input?

A: The module requires a regulated 24 VDC input. Ensure the power source is capable of meeting the startup inrush current and maintaining voltage stability within the specified limits to prevent processor resets or logic execution instability.

Field Installation Guidelines

  1. Ensure the controller chassis is de-energized before mounting the 5X00481G01 CPU module into the primary controller slot.
  2. Align the CPU module carefully with the chassis backplane connectors to prevent pin bending or connector misalignment.
  3. Secure the module using the built-in locking mechanisms to ensure vibration resistance in the control cabinet.
  4. Verify all network and I/O bus cable connections are firmly seated and that shielding drain wires are properly terminated to the cabinet ground bus.
  5. Upon power-up, observe the status LEDs on the module faceplate to confirm the CPU has passed its self-diagnostic test and has established communication with the Ovation control network.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Demystifying CPU Communication Ports in Siemens PLC Architectures

Demystifying CPU Communication Ports in Siemens PLC Architectures

Industrial automation relies heavily on robust data exchange between devices. Without seamless connectivity, field instruments, network switches, human-machine interfaces, and programmable logic controllers cannot coordinate effectively. Therefore, understanding the various CPU communication ports available in Siemens hardware ensures efficient factory automation design and seamless system integration.

Read more
Mastering the Siemens PLC Scan Cycle: How the CPU Executes Automation Programs

Mastering the Siemens PLC Scan Cycle: How the CPU Executes Automation Programs

Industrial automation relies heavily on programmable logic controllers (PLCs) to manage complex manufacturing processes. Many engineers dive straight into programming without mastering the underlying architecture. However, understanding how a PLC CPU executes a program ensures reliable system design. Therefore, mastering the scan cycle optimizes both performance and troubleshooting in modern control systems.

Read more
How to Connect to Siemens S7 PLCs: 5 Essential Communication Methods

How to Connect to Siemens S7 PLCs: 5 Essential Communication Methods

Establishing a reliable hardware link between a programming terminal and a Siemens SIMATIC controller is essential for engineering workflows. Field engineers rely on distinct physical layers, ranging from legacy serial connections to high-speed Industrial Ethernet protocols. Modern factory automation environments prioritize fast data transfer and seamless driver integration. Selecting the correct connection method simplifies program downloads, online monitoring, and system troubleshooting in complex control systems.

Read more