DSPC173 57310001-MT | ABB | Repeater ModuleDSPC173 57310001-MT | ABB | Repeater ModuleDSPC173 57310001-MT | ABB | Repeater Module
DSPC173 57310001-MT | ABB | Repeater Module
DSPC173 57310001-MT | ABB | Repeater Module
DSPC173 57310001-MT | ABB | Repeater Module

DSPC173 57310001-MT | ABB | Repeater Module


Only 10 left - Selling fast

PRODUCT SKU : DSPC173 57310001-MT

PRODUCT TYPE : Communication Modules

PRODUCT VENDOR : ABB


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The ABB DSPC173 57310001-MT, also cataloged as the DSPC173 Repeater Module, operates as a dedicated hardware component for localized control logic execution within ABB bus networks. Configured for signal amplification and electrical isolation across extended bus topologies, the assembly reconstructs degraded transmission signals to provide direct physical/electrical execution of real-time communication frames.

Hardware Specifications

Parameter Specification
Model DSPC173 57310001-MT
Brand ABB
Origin Switzerland / Sweden (Standard production origin matrix)
Weight 0.3 kg
Dimensions 254 mm x 254 mm x 25 mm
Operating Temp 0 to 60 deg C (Nominal industrial standard)
Power Consumption System backplane bus powered
Product Type Communication Modules

Profinet / EtherNet/IP Deterministic Networks and I/O Density Scaling

The internal signal conditioning circuits of the ABB DSPC173 57310001-MT are calibrated to maintain strict alignment with design-specified backplane bus communication velocity metrics. When bridging segmented local architecture fields to broader Profinet or EtherNet/IP deterministic networks, the hardware minimizes propagation delay and prevents packet collision. The physical sub-assembly configuration isolates noise vectors during massive I/O density scaling phases, ensuring that local node branch extensions operate reliably within the bounds of host controller firmware flash compatibility parameters.

Frequently Asked Questions

Q: Is hot-swapping or live extraction of the DSPC173 repeater card supported while the system backplane is energized?

A: No. The board lacks dedicated live-insertion isolation switches. Removing or re-inserting the hardware component while the bus segments are powered can introduce transient voltage arcs, potentially causing data corruption on adjacent network nodes or permanent physical trace damage.

Q: How is signal link degradation diagnosed on the DSPC173 module?

A: Status indication loops must be verified through the centralized system controller diagnostic registers. If attenuation faults occur, check for proper input voltage thresholds from the backplane and verify that the connected network lengths do not exceed maximum specified segment distances.

Field Installation Guidelines

  1. ESD Handling Requirements: Field technicians must wear a properly grounded electrostatic discharge (ESD) wrist strap prior to removing the hardware from its shielding packaging to prevent latent dielectric breakdown.
  2. Chassis Alignment and Fastening: Slide the card smoothly along the dedicated chassis enclosure guide channels to prevent pin deformation on the backplane interface. Tighten all front faceplate screws to maintain structural ground continuity under continuous plant vibration.
  3. Data Cable Routing Separation: Route all external network communication lines through separate low-voltage wireways. Maintain a physical clearance of at least 100 mm from power distribution conductors and variable frequency drive motor leads to mitigate inductive coupling.
  4. Environmental Control Verification: Ensure the module is situated in an IP 54 or better enclosure free from moisture condensation and airborne conductive soot to avoid physical tracking short-circuits on the unshielded circuit paths.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Instrumentation Control Systems in Modern Industrial Automation

Understanding Instrumentation Control Systems in Modern Industrial Automation

An instrumentation control system (ICS) serves as the central nervous system of modern manufacturing plants and processing facilities. Engineers classify these setups as Electrical, Electronic, or Programmable Electronic Systems (E/E/PES). In practice, an ICS bridges the physical world of industrial machinery with digital decision-making tools. Therefore, understanding its architecture is essential for anyone working in factory automation, process control, or plant safety.

Read more
Mastering Electrical Grounding Fundamentals in Industrial Automation and Control Systems

Mastering Electrical Grounding Fundamentals in Industrial Automation and Control Systems

Electrical grounding is a complex engineering discipline. It requires deep knowledge of soil composition and conductor materials. National Electrical Code (NEC) Article 250 outlines these requirements clearly. Many engineers confuse grounding, earthing, and bonding. Grounding connects circuits to a common reference point. Earthing specifically links equipment directly to the planet. Bonding permanently joins metallic parts to ensure electrical continuity.

Read more
Architectural Blueprint of Industrial Automation and Control Systems (IACS): Standards, Safety, and Remote Operations

Architectural Blueprint of Industrial Automation and Control Systems (IACS): Standards, Safety, and Remote Operations

According to IEC 62443, Industrial Automation and Control Systems (IACS) integrate personnel, hardware, and software. These components collectively influence the safety and reliability of any industrial process. Modern control systems allow extensive remote monitoring and operation. However, enabling remote capabilities introduces complex cybersecurity challenges. Therefore, facility operators must evaluate system functions carefully before expanding connectivity.

Read more