Only 10 left - Selling fast

PRODUCT SKU : ADV561-P00

PRODUCT TYPE : Digital Output Module

PRODUCT VENDOR : Yokogawa


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The Yokogawa ADV561-P00 serves as an ultra-high-density digital output solution for the CENTUM VP integrated production control system. This module manages 64 discrete output channels, allowing the simultaneous control of extensive field device arrays such as solenoid valves, relays, and indicators. Its high-capacity design significantly reduces the physical footprint within control cabinets while maintaining the high-speed switching capabilities required for complex process logic.

Part Number Breakdown

Yokogawa hardware utilizes specific suffix logic to define functional capabilities:

  • ADV561: Digital Output Module (64-channel, 24 V DC)

  • -P: Supports Pulse-Width and mixed status/pulse output functionality

  • 0: Standard type configuration

  • 0: Basic environmental protection (Non-conformal coating)

Technical Specifications

The ADV561-P00 provides the following technical parameters for precise field control:

  • Output Channels: 64 points

  • Rated Applied Voltage: 24 V DC

  • Voltage Range: 20.4 to 26.4 V DC

  • Maximum Load Current: 100 mA per channel @ 26.4 V

  • Response Time (Status): ≤ 3 ms

  • Response Time (Pulse): ≤ 10 ms (Mixed status and pulse)

  • Pulse Width Resolution: 8 ms increments

  • Withstanding Voltage: 2 kV AC between signal and system; 500 V AC between commons

  • Internal Current Draw: 700 mA @ 5 V DC

  • Weight: 0.30 kg

Engineering Advantages

  • Maximized Cabinet Efficiency: Packing 64 channels into a single module slot enables engineers to consolidate hardware and reduce the number of required I/O racks. This solves space constraints in offshore platforms and crowded control rooms.

  • Precision Pulse Logic: The module handles pulse-width modulation with 8 ms resolution. This feature allows for the direct control of devices requiring specific duty cycles or timed pulses without taxing the central controller's processing power.

  • Superior Signal Integrity: 2 kV AC withstanding voltage between the output signal and system logic prevents field-side electrical noise from migrating into the system backplane. Additionally, the module groups channels every 16 points with 500 V AC isolation between commons to mitigate cross-channel interference.

  • Streamlined Connectivity: The ADV561-P00 utilizes a dedicated MIL connector interface (AKB337). This high-density connection method eliminates the clutter of individual screw terminals, accelerating the wiring process and reducing the risk of installation errors.

FAQs

Is this ADV561-P00 unit brand new?

Yes. We supply the Yokogawa ADV561-P00 as a 100% Brand New, original factory unit. Each module ships in its original packaging with full traceability.

How do I manage the wiring for 64 channels?

The module requires a dedicated MIL connector cable, specifically the Yokogawa AKB337. This cable connects the high-density faceplate to a remote terminal board, ensuring organized cable management and secure electrical contact.

Can I use this module for high-frequency switching?

The ADV561-P00 offers a status response time of 3 ms or less. For mixed status and pulse applications, the response time remains under 10 ms. This allows the module to handle rapid sequence-of-events and high-speed control loops in process automation.

What is the significance of the "common minus" grouping?

The module organizes its 64 channels into groups of 16, sharing a negative (-) common for each group. This architecture provides 500 V AC isolation between these common groups, offering an additional layer of protection against localized electrical faults affecting the entire module.

 

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Modern Programmable Logic Controllers manage execution through distinct operational states: Run, Stop, Start-Up, and Hold. During power-up, a controller initializes memory registers within Stop mode before briefly transitioning to Start-Up mode. During this phase, internal self-diagnostics evaluate system integrity across hardware and user programs. If the controller detects no critical faults, it enters Run mode to execute the control program continuously. However, any severe system anomaly forces the CPU back into Stop mode immediately to prevent erratic machine behavior across the plant floor.

Read more
Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interfaces (HMIs) serve as the primary operational window into complex industrial automation systems. Modern HMIs convert raw machine data into clear graphical displays, enabling operators to oversee entire manufacturing processes in real time. Instead of relying on physical control panels full of hardwired switches, engineers program interactive screens using intuitive graphics, dynamic color coding, and responsive touch interfaces. Over my 15 years in control systems engineering, I have observed HMIs transform from basic display screens into sophisticated command centers that drive operational efficiency across DCS and PLC environments.

Read more
Understanding Safety Relays in Industrial Automation: Architecture, Operation, and Functional Safety

Understanding Safety Relays in Industrial Automation: Architecture, Operation, and Functional Safety

Standard electromechanical relays provide basic electrical isolation between low-voltage control circuits and high-power output loads. A traditional switching relay features a magnetic coil driving mechanical Common (COM), Normally-Open (NO), and Normally-Closed (NC) contacts. However, standard relays pose severe functional risks when deployed in critical safety interlock circuits. High current inrush or mechanical wear can weld contacts together permanently. If contact welding occurs in an emergency stop circuit, pressing the button fails to halt hazardous machinery movements. Consequently, global functional safety standards prohibit standard relays for critical machine guarding functions.

Read more