Skip to content

What are you looking for?


You may also like

BMXAMM0600 | Schneider Electric | Modicon X80 Mixed Analog I/O ModuleBMXAMM0600 | Schneider Electric | Modicon X80 Mixed Analog I/O ModuleBMXAMM0600 | Schneider Electric | Modicon X80 Mixed Analog I/O Module
BMXAMM0600 | Schneider Electric | Modicon X80 Mixed Analog I/O Module
BMXAMM0600 | Schneider Electric | Modicon X80 Mixed Analog I/O Module
BMXAMM0600 | Schneider Electric | Modicon X80 Mixed Analog I/O Module

BMXAMM0600 | Schneider Electric | Modicon X80 Mixed Analog I/O Module


Only 10 left - Selling fast

PRODUCT SKU : BMXAMM0600

PRODUCT TYPE : Analog I/O Module

PRODUCT VENDOR : Schneider


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The Schneider Electric BMXAMM0600 executes simultaneous analog signal acquisition and process instrumentation control within the Modicon X80 automation environment. This compact, high-level mixed module integrates 4 analog input channels and 2 analog output channels into a single physical card slot. By combining both functions, the module directly interfaces with field transmitters, control valves, flow sensors, and variable frequency drives, acting as a space-saving multi-signal interface for standalone machine control, pumping stations, and local processing loops.

Technical Specifications

Parameter Technical Specification Value
Manufacturer Schneider Electric
Model BMXAMM0600
Range of Product Modicon X80
Product Type High-Level Mixed Analog Input/Output Module
Condition 100% Brand New Original
Analogue Input Count 4 high-level channels (Non-isolated between channels)
Analogue Input Types

Current: 0...20 mA, 4...20 mA


Voltage: +/- 10 V, 0...10 V, 0...5 V, 1...5 V

Analogue Input Resolution

12 bits (Current & 0...5V/1...5V)


13 bits (0...10V)


14 bits (+/- 10V)

Analogue Output Count 2 high-level channels
Analogue Output Types

Current: 0...20 mA, 4...20 mA


Voltage: +/- 10 V

Analogue Output Resolution

11 bits (Current)


12 bits (+/- 10 V)

Bus Galvanic Isolation

1400 V DC between channels and backplane bus/ground


750 V DC between I/O channel groups

Input Impedance (Current) 250 Ohm (backed by 0.1% precision internal resistor)
Conversion & Read Times

Input Read: 5 ms (for 4 channels)


Output Conversion: <= 2 ms

Mean Time Between Failures 1,400,000 Hours (MTBF)
Physical Wiring Connection Single 20-way connector
Product Net Weight 0.342 lb (0.155 kg)

Engineering Advantages

  • Footprint Consolidation via Mixed Architecture: Small control enclosures offer highly restricted mounting spaces. The BMXAMM0600 resolves this mechanical constraint by grouping 4 distinct input loops and 2 output loops into a single 1.3-inch wide module slot. This integration eliminates the need to buy separate input and output cards, reducing total rack dimensions and shrinking hardware bills of materials.

  • Robust Bus-Level Voltage Protection: Industrial field wiring frequently exposes electronics to inductive spikes. While sharing local grounds within the module, the BMXAMM0600 protects your central PAC processor by maintaining a 1400 V DC galvanic isolation barrier between all physical channels and the backplane bus, and a 750 V DC isolation layer between the input and output groups.

  • Flexible Multi-Range Field Adaptation: Different sensor types utilize varying electrical standards. This module accepts mixed voltage and current formats simultaneously, supporting +/- 10 V, 0...10 V, 0...5 V, 1...5 V, 0...20 mA, and 4...20 mA. Field technicians change these ranges on a per-channel basis inside the EcoStruxure programming software without manipulating physical switches.

  • Ruggedized Fault Handling and Fallbacks: Complete communication loss can cause dangerous process behavior. The module incorporates configurable fallback modes that force the 2 analog outputs to hold their last valid value or ramp immediately to a predefined safe milliamp/voltage level, safeguarding physical downstream valves and motors.

  • Firmware-Based Digital Filtering: High-frequency ambient electromagnetic interference (EMI) degrades sensor reading precision. Built-in first-order digital filtering, executed natively by the internal firmware, suppresses high-frequency line ripple to deliver stabilized, noise-free numerical data directly to the controller memory.

FAQs

  • Is this BMXAMM0600 mixed analog module a brand new original unit?

    Yes. We supply this component strictly as a 100% brand new, original factory-sealed unit. It arrives inside its authentic Schneider Electric box with factory warranties, quality certifications, and protective materials intact.

  • Does this module feature point-to-point isolation between the individual inputs?

    No. The 4 analog input channels are non-isolated from each other and share a common internal ground loop. However, the module provides a comprehensive 1400 V DC isolation barrier between the I/O channels as a collective group and the internal backplane bus.

  • What happens if a field device feeds an excessive current or voltage to the input channel?

    The module possesses robust, built-in protection parameters. It sustains permitted overloads up to +/- 30 mA in current modes and up to +/- 30 V in voltage configurations without burning out the 0.1% precision internal conversion resistor.

  • How does the card signify real-time circuit status to field operators?

    The front face features a clear, multi-LED local signaling array. A green RUN LED indicates active module operation, a red ERR LED tracks internal hardware problems, an I/O fault light signals field wiring errors, and individual green LEDs provide diagnostic status for each of the active channels.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Transforming Shop Floor Data into Actionable Insights: A Deep Dive into MES

Transforming Shop Floor Data into Actionable Insights: A Deep Dive into MES

Manufacturing Execution Systems serve as the digital backbone of modern factory floors. Positioned at Level 3 of the ISA-95 automation pyramid, MES links enterprise resource planning with real-time shop floor control systems. Today, industrial operators rely on MES software to bridge operational strategy with physical production execution.

Read more
Managed Switch vs. Unmanaged Switch: Industrial Ethernet Architecture

Managed Switch vs. Unmanaged Switch: Industrial Ethernet Architecture

Industrial Ethernet forms the backbone of factory automation. Selecting the right switch architecture determines system uptime, data throughput, and OT cyber resilience. This technical guide evaluates managed vs. unmanaged switches, analyzing operational differences, security controls, and selection criteria.
Read more
Hot Standby vs. Cold Standby Redundancy in Industrial Automation

Hot Standby vs. Cold Standby Redundancy in Industrial Automation

System availability determines process safety and productivity in industrial automation. Control engineers deploy redundancy to eliminate single points of failure. This technical guide evaluates Hot Standby vs. Cold Standby architectures, comparing failover speeds, memory sync, cost trade-offs, and field selection criteria.

Read more