Product Details
Product Overview
The Schneider Electric BMXAMI0810H captures high-level analog field signals under extreme operating conditions within the Modicon X80 automation platform. This rugged, 8-channel analog input module provides full channel-to-channel electrical isolation to digitize current and voltage signals from pressure transmitters, flow meters, thermal sensors, and level indicators. Engineered specifically with protective treatments for severe environments, this module prevents ground-loop distortions and maintains measurement stability across offshore platforms, chemical processing plants, pipeline pumping stations, and heavy metallurgical facilities.
Technical Specifications
| Parameter | Technical Specification Value |
| Manufacturer | Schneider Electric |
| Model | BMXAMI0810H |
| Range of Product | Modicon X80 |
| Product Type | Analog Input Module |
| Condition | 100% Brand New Original |
| Product Application | Ruggedized for severe environments |
| Number of Channels | 8 high-level inputs |
| Channel Isolation | Fully isolated channel-to-channel |
| Supported Current Input Ranges | $\pm 20 \text{ mA}$, $0\dots20 \text{ mA}$, $4\dots20 \text{ mA}$ |
| Supported Voltage Input Ranges | $\pm 10 \text{ V}$, $\pm 5 \text{ V}$, $0\dots10 \text{ V}$, $0\dots5 \text{ V}$, $1\dots5 \text{ V}$ |
| Analog-to-Digital Conversion | 16 bits |
| Measurement Resolution |
15 bits + sign 0.36 mV for voltage modes 1.4 µA for current modes |
| Permitted Overload on Inputs |
$\pm 30 \text{ mA}$ (Current modes) $\pm 30 \text{ V}$ (Voltage modes) |
| Input Impedance |
10 MOhm (Voltage mode) 250 Ohm + $3.6\dots50 \text{ Ohm}$ protective resistor (Current mode) |
| Internal Resistor Precision | 0.1% accuracy with a low 15 ppm/°C temperature coefficient |
| Signal Filtering Type | First-order digital filtering |
| Nominal Read Cycle Time | 9 ms for all 8 active channels |
| Fast Read Cycle Calculation | 1 ms + 1 ms × number of channels used |
| Measurement Error at 25 °C |
0.15% of full scale (Current modes) 0.075% of full scale (Voltage modes) |
| Measurement Error at -25...70 °C |
$\le 0.55\%$ of full scale (Current modes) $\le 0.2\%$ of full scale (Voltage modes) |
| Temperature Drift Coefficients |
50 ppm/°C (Current modes) 30 ppm/°C (Voltage modes) |
| Noise Rejection Ratios |
80 dB minimum crosstalk attenuation 80 dB common mode rejection |
| Digital Value Data Format | -32768 to +32767 user scale ($\pm 10000$ by default) |
| Isolation Voltage Ratings |
300 V DC between channels 1400 V DC between channels and ground 1400 V DC between channels and backplane bus |
| Mean Time Between Failures | 900,000 Hours (MTBF) |
| Operating Altitude Capabilities |
Up to 6561.68 ft (2000 m) without derating 2000 m up to 5000 m with applied derating factor |
| Physical Interface Connector | 1 x 28-way high-density connector slot |
| Power Consumption Parameters |
1.06 W (Typical) / 1.50 W (Maximum) at 24 V DC 0.32 W (Typical) / 0.48 W (Maximum) at 3.3 V DC |
| Backplane Current Draw | 150 mA at 3.3 V DC / 54 mA at 24 V DC |
| Product Net Weight | 0.386 lb (0.175 kg) |
Engineering Advantages
-
True Channel-to-Channel Electrical Isolation: Ground potential differences between remote field instruments can inject stray electrical currents into shared analog return paths, corrupting sensor data. The BMXAMI0810H eliminates this interference by enforcing a strict 300 V DC isolation barrier between every individual analog channel. It duplicates this safety margin by deploying a 1400 V DC isolation barrier between the signal channels, the station ground, and the main backplane bus, protecting delicate logic processors from high-voltage field spikes.
-
Severe-Environment Conformal Hardening: Standard electronic component coatings corrode and short-circuit when exposed to airborne salt spray, acidic industrial vapors, and persistent humidity. As part of the Modicon X80 ruggedized lineup, this module features enhanced protective treatments on its internal circuit boards. This chemical hardening extends stable 16-bit analog sampling down into an expanded temperature window spanning -25°C to 70°C.
-
Ultra-High 900,000-Hour Reliability Profile: Unplanned factory downtime on remote oil pipelines or critical offshore rigs causes immediate financial loss. The BMXAMI0810H achieves an exceptional Mean Time Between Failures (MTBF) rating of 900,000 hours. This long operational lifespan stems from a low-thermal, highly optimized internal design that consumes a mere 1.06 Watts of typical 24V DC backplane power, minimizing component heat stress.
-
Dynamic Variable-Speed Scan Optimization: High-frequency pulsation monitoring requires faster analog updates than standard tank-level monitoring. This module features a flexible conversion matrix that executes a fast read cycle calculated at 1 ms + 1 ms per active channel. If a field system requires sub-5 millisecond responses, engineers simply disable unused channels in software to tighten the hardware scan rate down to a crisp 3 ms interval for two sensors.
-
High-Altitude Air Dissipation Compliance: Thin air at high elevations diminishes the convective cooling capacity of traditional industrial hardware, causing overheating. This ruggedized module adapts to high-altitude facilities seamlessly, operating at full capacity up to 6561.68 feet (2000 meters) without structural adjustments. It also supports deep installation up to 5000 meters when users apply standard system thermal derating factors during panel design.
FAQs
-
Is this BMXAMI0810H analog module a brand new original unit?
Yes. We supply this product exclusively as a 100% brand new, original factory-sealed unit. The module comes packed in its original Schneider Electric corporate carton, complete with all factory anti-corrosion desiccant packs, untouched pin protectors, and original serialization labels.
-
What is the difference between this "H" version and the standard BMXAMI0810 model?
The "H" designation stands for Hardened severe-environment construction. While the standard module operates only under everyday climate ranges, this ruggedized unit features specialized conformal surface coatings to withstand corrosive gases, high-humidity atmospheres, and an expanded temperature range from -25°C up to 70°C.
-
Does the module require an external calibration instrument to maintain its 16-bit precision?
No. The module utilizes internal precision conversion resistors boasting a tight 0.1% tolerance rating combined with an ultra-low 15 ppm/°C temperature coefficient. This premium hardware configuration auto-compensates for component warming, removing the need for regular manual field potentiometer calibration tweaks.
-
How do the front-panel diagnostic lights simplify field loop troubleshooting?
The module features an informative array of faceplate LEDs that stream immediate diagnostic statuses. A green RUN LED indicates active backplane communication. If a sensor wire breaks or experiences an over-range voltage spike, the module illuminates a red I/O or ERR LED while concurrently lighting up the individual green status indicator of the failing channel to isolate the exact loop problem instantly.
Additional Information
- 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
- 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
- 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
- Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
- Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
- Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.