PRODUCT SKU : 3300/55-03-04-16-00-00-05-02

PRODUCT TYPE : Vibration Monitors

PRODUCT VENDOR : Bently Nevada


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The Bently Nevada 3300/55-03-04-16-00-00-05-02 is a two-channel velocity monitoring module designed for continuous online measurement of machinery vibration. This specific configuration supports Velomitor transducers with a 100 mV/in/s sensitivity and uses SpringLoc terminal connectors for secure field wiring. It is engineered for panel-mounted 3300 system racks to provide reliable machinery protection and alarm signaling.

Signal Processing and Transducer Compatibility

The module accepts dual velocity inputs from compatible Velomitor sensors to track vibration parameters. Both channels process input signals to report vibration characteristics within the configured range. Epoxy-sealed relays provide robust alarm signaling capabilities for trip and alert conditions.

Configuration and Installation

The unit features panel-mounted architecture and relies on SpringLoc terminal strips for fast cable termination. Proper installation requires secure mounting in a standard 3300 rack with appropriate grounding and shielded cabling to maintain signal integrity. Alarm thresholds are configured via compatible programming modules within the rack system.

Parameter Specification
Brand Bently Nevada
Model 3300/55-03-04-16-00-00-05-02
Product Type Two-Channel Vibration Monitor
Channel Input Option Dual velocity inputs (reporting peak-to-peak displacement)
Transducer Type Velomitor (100 mV/in/s sensitivity)
Relay Type Epoxy-sealed relays
Connector Type SpringLoc terminal strip
Mounting Type Panel mount
Agency Approval None (non-hazardous area use)
Safety Barriers None

Frequently Asked Questions

Q: What type of transducers are compatible with this monitor?

A: It is designed to work with Velomitor transducers featuring a sensitivity of 100 mV/in/s.

Q: What type of wiring terminals does this module use?

A: It utilizes SpringLoc terminal connectors to facilitate fast and secure field wiring.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Redefining Control System Design: The Evolution of Flexible Input/Output Modules (FIOM) in Industrial Automation

Redefining Control System Design: The Evolution of Flexible Input/Output Modules (FIOM) in Industrial Automation

Traditional industrial automation relies heavily on dedicated input-output (IO) modules. In a standard distributed control system (DCS) or programmable logic controller (PLC) setup, design engineers assign specific cards to distinct signal types. For instance, a traditional 16-channel digital input (DI) card exclusively processes digital signals. However, engineering projects frequently encounter last-minute changes in signal counts. Therefore, discovering a missing analog input (AI) channel late in the design phase forces engineers to purchase and install an entirely new, dedicated AI card. Consequently, this rigidity drives up hardware expenses, wastes cabinet space, and delays commissioning schedules.

Read more
Mastering VFD Braking Theory and Mechanical Brake Sequencing in Industrial Automation

Mastering VFD Braking Theory and Mechanical Brake Sequencing in Industrial Automation

In industrial automation, variable frequency drives (VFDs) regulate motor speed and torque across manufacturing plants and material handling systems. However, certain heavy-duty applications experience external loads that can rotate the motor shaft without an active command. For instance, gravity pulls loads downward in unanchored hoisting equipment. Therefore, engineers integrate mechanical brakes with VFD logic to maintain absolute safety and prevent structural damage or personnel injury during shutdowns.

Read more
Optimizing Tank Level Control Using Proportional Algorithms in PLC Systems

Optimizing Tank Level Control Using Proportional Algorithms in PLC Systems

Industrial automation engineers frequently encounter liquid level regulation challenges across diverse process plants. Traditional ON-OFF control mechanisms often disrupt system stability due to abrupt actuator switching. Therefore, upgrading to closed-loop architectures like proportional control yields smoother responses. In a typical PLC environment, such as Siemens TIA Portal, engineers utilize closed-loop feedback to minimize process errors without requiring full PID complexity.

Read more