Skip to content

What are you looking for?


You may also like

Bently Nevada 3300/16-02-01-02-01-00-00 XY/Gap Dual Vibration MonitorBently Nevada 3300/16-02-01-02-01-00-00 XY/Gap Dual Vibration MonitorBently Nevada 3300/16-02-01-02-01-00-00 XY/Gap Dual Vibration Monitor
Bently Nevada 3300/16-02-01-02-01-00-00 XY/Gap Dual Vibration Monitor
Bently Nevada 3300/16-02-01-02-01-00-00 XY/Gap Dual Vibration Monitor
Bently Nevada 3300/16-02-01-02-01-00-00 XY/Gap Dual Vibration Monitor

Bently Nevada 3300/16-02-01-02-01-00-00 XY/Gap Dual Vibration Monitor


Only 10 left - Selling fast

PRODUCT SKU : 3300/16-02-01-02-01-00-00

PRODUCT TYPE : Dual Vibration Monitors

PRODUCT VENDOR : Bently Nevada


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The Bently Nevada 3300/16-02-01-02-01-00-00 is a dual-channel vibration monitoring module designed for the 3300 Series rack system. This unit tracks radial shaft vibration and transducer gap voltage to support machinery protection in critical industrial rotating assets.

Dual-Channel Monitoring and Measurement

The module provides dual-channel inputs optimized for proximity probe sensing to continuously monitor radial vibration and probe gap voltage. Processing these parameters enables early identification of mechanical conditions such as rotor misalignment, shaft rubs, and bearing degradation.

Alarm Processing and System Integration

Integrated alarm processing delivers dedicated Alert and Danger relay outputs alongside front-panel LED indicators for real-time status tracking of OK, Bypass, Alert, and Danger conditions. The unit also provides 4–20 mA proportional output signals for direct integration with external control systems and data recorders.

Installation Guidelines

Ensure the 3300 rack is powered down before inserting or removing the module to prevent electrical damage.

The module must be seated firmly within the designated rack slot to ensure proper backplane connection. Use shielded cabling for all transducer inputs to minimize electromagnetic interference and ensure signal integrity, and verify that field wiring aligns with site grounding practices. Perform a full system check, including alarm setpoint verification, before placing the machine into operational service.

Parameter Specification
Model 3300/16-02-01-02-01-00-00
Brand Bently Nevada
Series 3300
Product Type Dual Vibration Monitor
Inputs 2 x Proximity probe channels
Outputs Dynamic signals, 4–20 mA, Relay (Alert/Danger)
Operating Temp -30 degC to +65 degC
Power Consumption Approx. 6 W

Frequently Asked Questions

Q: What does the 3300/16-02-01-02-01-00-00 model configuration indicate?

A: This specific order code denotes the base 3300/16 monitor with dual-channel XY/Gap functionality, standard industrial safety approvals, proximity probe transducer inputs, and standard relay/barrier configurations.

Q: Can this module be hot-swapped?

A: While the 3300 series is designed for industrial reliability, it is standard engineering practice to follow facility safety protocols regarding power isolation before performing maintenance or module replacement.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Redefining Control System Design: The Evolution of Flexible Input/Output Modules (FIOM) in Industrial Automation

Redefining Control System Design: The Evolution of Flexible Input/Output Modules (FIOM) in Industrial Automation

Traditional industrial automation relies heavily on dedicated input-output (IO) modules. In a standard distributed control system (DCS) or programmable logic controller (PLC) setup, design engineers assign specific cards to distinct signal types. For instance, a traditional 16-channel digital input (DI) card exclusively processes digital signals. However, engineering projects frequently encounter last-minute changes in signal counts. Therefore, discovering a missing analog input (AI) channel late in the design phase forces engineers to purchase and install an entirely new, dedicated AI card. Consequently, this rigidity drives up hardware expenses, wastes cabinet space, and delays commissioning schedules.

Read more
Mastering VFD Braking Theory and Mechanical Brake Sequencing in Industrial Automation

Mastering VFD Braking Theory and Mechanical Brake Sequencing in Industrial Automation

In industrial automation, variable frequency drives (VFDs) regulate motor speed and torque across manufacturing plants and material handling systems. However, certain heavy-duty applications experience external loads that can rotate the motor shaft without an active command. For instance, gravity pulls loads downward in unanchored hoisting equipment. Therefore, engineers integrate mechanical brakes with VFD logic to maintain absolute safety and prevent structural damage or personnel injury during shutdowns.

Read more
Optimizing Tank Level Control Using Proportional Algorithms in PLC Systems

Optimizing Tank Level Control Using Proportional Algorithms in PLC Systems

Industrial automation engineers frequently encounter liquid level regulation challenges across diverse process plants. Traditional ON-OFF control mechanisms often disrupt system stability due to abrupt actuator switching. Therefore, upgrading to closed-loop architectures like proportional control yields smoother responses. In a typical PLC environment, such as Siemens TIA Portal, engineers utilize closed-loop feedback to minimize process errors without requiring full PID complexity.

Read more