AMN31 S1 YOKOGAWA Rack ChassisAMN31 S1 YOKOGAWA Rack ChassisAMN31 S1 YOKOGAWA Rack Chassis
AMN31 S1 YOKOGAWA Rack Chassis
AMN31 S1 YOKOGAWA Rack Chassis
AMN31 S1 YOKOGAWA Rack Chassis

AMN31 S1 YOKOGAWA Rack Chassis


Only 10 left - Selling fast

PRODUCT SKU : AMN31 S1

PRODUCT TYPE : Rack Chassis

PRODUCT VENDOR : Yokogawa


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The YOKOGAWA AMN31 S1, also cataloged as the AMN31 Rack Chassis, operates as a dedicated hardware component for housing terminal I/O modules and distributing backplane power within CENTUM CS 3000 and CENTUM CS networks. The enclosure provides 31 physical slots and maintains structural and electrical connectivity for discrete and analog signal processing cards operating on the local control bus.

Hardware Specifications

Parameter Specification
Model AMN31 S1 / AMN31
Brand YOKOGAWA
Weight 0.9 kg (2.0 lbs)
Dimensions 12.7 x 15.2 x 25.4 cm (5.0 x 6.0 x 10.0 in)
Operating Temp -20 to 60 deg C
Power Consumption 100 W
Input Voltage 24 VDC
Module Slots 31 slots
Operating Humidity 5% to 95% RH (non-condensing)
Protection Rating NEMA 4X / IEC IP66
Target System CENTUM CS 3000 / CENTUM CS

Channel-to-Channel Isolation and Process Integration

When populated with terminal I/O modules, the AMN31 S1 backplane structure supports strict channel-to-channel isolation architectures. This physical separation prevents ground loop propagation across the 31 available hardware slots. By maintaining electrical independence between adjacent termination blocks, the chassis ensures that high-voltage field transients on one circuit do not disrupt analog or digital measurement loops communicating via the internal DCS data bus.

Frequently Asked Questions

Q: What is the maximum module capacity of the AMN31 S1 rack chassis?

A: The nest chassis provides exactly 31 physical slots for installing compatible terminal I/O modules within the CENTUM DCS architecture.

Q: What are the backplane power supply requirements for the unit?

A: The chassis consumes a maximum of 100 W when supplied with a nominal 24 VDC input power source.

Q: What environmental ingress protection does the AMN31 S1 provide?

A: The chassis is constructed to meet NEMA 4X and IEC IP66 protection ratings, making it suitable for environments requiring resistance against dust and directed water spray.

Field Installation Guidelines

De-energize all 24 VDC supply lines before terminating power cables to the AMN31 S1 chassis. Mount the nest securely using the designated mechanical fastening points, ensuring sufficient clearance around the 12.7 x 15.2 x 25.4 cm enclosure to maintain adequate thermal dissipation for the 100 W continuous load. Seat individual I/O modules firmly into the 31 available slots and lock their retaining mechanisms to maintain backplane pin continuity. Bond the enclosure chassis ground terminal directly to the main cabinet earth bar using a heavy-gauge braided strap to minimize electromagnetic interference (EMI). Route 24 VDC power lines separately from field signal cables to prevent inductive cross-talk.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Industrial automation systems rely heavily on Programmable Logic Controllers (PLCs) to maintain uninterrupted production. When a PLC unexpectedly shifts from Run to Stop mode, whole manufacturing lines stall.

As control systems evolve across modern factory automation, understanding the root causes of these interruptions helps engineers minimize costly downtime. This technical guide breaks down why PLCs trip into Stop mode and provides practical strategies to mitigate system faults.

Read more
Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Modern Programmable Logic Controllers manage execution through distinct operational states: Run, Stop, Start-Up, and Hold. During power-up, a controller initializes memory registers within Stop mode before briefly transitioning to Start-Up mode. During this phase, internal self-diagnostics evaluate system integrity across hardware and user programs. If the controller detects no critical faults, it enters Run mode to execute the control program continuously. However, any severe system anomaly forces the CPU back into Stop mode immediately to prevent erratic machine behavior across the plant floor.

Read more
Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interfaces (HMIs) serve as the primary operational window into complex industrial automation systems. Modern HMIs convert raw machine data into clear graphical displays, enabling operators to oversee entire manufacturing processes in real time. Instead of relying on physical control panels full of hardwired switches, engineers program interactive screens using intuitive graphics, dynamic color coding, and responsive touch interfaces. Over my 15 years in control systems engineering, I have observed HMIs transform from basic display screens into sophisticated command centers that drive operational efficiency across DCS and PLC environments.