Skip to content

What are you looking for?


You may also like

AMM22 | Yokogawa Multiplexer Input Module for CENTUM SystemsAMM22 | Yokogawa Multiplexer Input Module for CENTUM SystemsAMM22 | Yokogawa Multiplexer Input Module for CENTUM Systems
AMM22 | Yokogawa Multiplexer Input Module for CENTUM Systems
AMM22 | Yokogawa Multiplexer Input Module for CENTUM Systems
AMM22 | Yokogawa Multiplexer Input Module for CENTUM Systems

AMM22 | Yokogawa Multiplexer Input Module for CENTUM Systems


Only 10 left - Selling fast

PRODUCT SKU : AMM22

PRODUCT TYPE : Multiplexer Input Module

PRODUCT VENDOR : Yokogawa


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The Yokogawa AMM22 is a robust multiplexer input module engineered for high-performance data acquisition within CENTUM CS and CENTUM VP distributed control systems. It is designed to efficiently handle multiple field signals—typically millivolt (mV) or thermocouple inputs—by multiplexing them into a single processing channel. This module addresses the critical need for high-density signal monitoring in space-constrained control panels, offering a 1 kHz high-speed conversion rate that ensures rapid and accurate data capture for dynamic industrial processes.

Technical Specifications

The AMM22 is built to withstand rigorous industrial environments while maintaining signal integrity.

Parameter Specification
Product Type Multiplexer Input Module
Model Number AMM22
Compatible Systems CENTUM CS, CENTUM VP
Conversion Speed 1 kHz (High-Speed)
Standard Output Signal 4-20 mA DC
Power Supply 24 V DC
Operating Temperature -10°C to +55°C
Dimensions 28 cm x 21 cm x 2 cm
Weight 1 kg

Model Code Interpretation

Understanding the suffix logic is essential for ensuring compatibility with your specific carrier and wiring setup.

Part Number: AMM22T

AMM22-AXX

  • A (Suffix -T): This suffix typically designates the Terminal Type.

    • -T: Indicates that the module features screw terminals for direct field wiring. This is distinct from the "-C" (Connector) version, which requires a specific mating cable.

    • Note: If your part number is AMM22M, the "M" often denotes a specific "Modified" or "Metric" version tailored for specific regional standards or carrier types.

Note: Always verify the physical interface (Terminal vs. Connector) against your control cabinet wiring to ensure a proper fit.

Installation and Wiring Guidelines

Proper installation is key to maximizing the performance of the AMM22 module.

  1. Carrier Compatibility: The AMM22 is designed to mount into specific I/O carrier boxes (such as the AMN series). Ensure the module is firmly seated in the slot and the locking mechanism is engaged to maintain backplane connectivity.

  2. Wiring Connections:

    • Signal Inputs: For the AMM22T (Terminal type), use a screwdriver to secure the field wires. Ensure the wire gauge matches the terminal specifications to prevent loose connections.

    • Thermocouple/MV: Since this module typically handles low-level signals, use shielded twisted-pair cables to minimize electromagnetic interference (EMI).

    • Grounding: Connect the shield to the ground terminal at the cabinet end to prevent noise from affecting the measurement accuracy.

  3. Power Supply: The module operates on a standard 24 V DC supply. Verify that the system power rail is stable and within the specified range before powering up the module.

  4. Thermal Management: Ensure adequate airflow around the module. The operating temperature range is -10°C to +55°C; exceeding this limit can cause drift in the high-speed conversion accuracy.

Frequently Asked Questions (FAQ)

Q: What is the primary function of the AMM22?A: The AMM22 acts as a multiplexer, allowing the system to scan and process multiple input channels (such as thermocouples or mV signals) sequentially using a single analog-to-digital converter, which increases channel density and efficiency.

Q: What does the "1 kHz" specification mean?A: This refers to the high-speed conversion rate. The module can sample and convert input signals at a rate of 1,000 times per second, making it suitable for processes requiring faster data updates.

Q: Is the AMM22 compatible with CENTUM VP?A: Yes, the AMM22 is designed for use in both CENTUM CS and the newer CENTUM VP systems, providing a reliable migration path for control system upgrades.

Q: Can I use this module for 4-20 mA inputs?A: While the standard output signal is listed as 4-20 mA DC (referring to the internal bus communication or converted signal), the AMM22 is primarily an input module for low-level signals like mV or Thermocouples. For direct 4-20 mA input, other models like the AMM42 or AAM10 series might be more appropriate depending on the specific application.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Industrial automation systems rely heavily on Programmable Logic Controllers (PLCs) to maintain uninterrupted production. When a PLC unexpectedly shifts from Run to Stop mode, whole manufacturing lines stall.

As control systems evolve across modern factory automation, understanding the root causes of these interruptions helps engineers minimize costly downtime. This technical guide breaks down why PLCs trip into Stop mode and provides practical strategies to mitigate system faults.

Read more
Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Modern Programmable Logic Controllers manage execution through distinct operational states: Run, Stop, Start-Up, and Hold. During power-up, a controller initializes memory registers within Stop mode before briefly transitioning to Start-Up mode. During this phase, internal self-diagnostics evaluate system integrity across hardware and user programs. If the controller detects no critical faults, it enters Run mode to execute the control program continuously. However, any severe system anomaly forces the CPU back into Stop mode immediately to prevent erratic machine behavior across the plant floor.

Read more
Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interface Design: Essential Guide to HMI Selection, Visualization, and Control System Integration

Human-Machine Interfaces (HMIs) serve as the primary operational window into complex industrial automation systems. Modern HMIs convert raw machine data into clear graphical displays, enabling operators to oversee entire manufacturing processes in real time. Instead of relying on physical control panels full of hardwired switches, engineers program interactive screens using intuitive graphics, dynamic color coding, and responsive touch interfaces. Over my 15 years in control systems engineering, I have observed HMIs transform from basic display screens into sophisticated command centers that drive operational efficiency across DCS and PLC environments.