Skip to content

What are you looking for?


You may also like

Allen-Bradley | Remote Termination Panel 1771-RTP4 Stand-Alone UnitAllen-Bradley | Remote Termination Panel 1771-RTP4 Stand-Alone UnitAllen-Bradley | Remote Termination Panel 1771-RTP4 Stand-Alone Unit
Allen-Bradley | Remote Termination Panel 1771-RTP4 Stand-Alone Unit
Allen-Bradley | Remote Termination Panel 1771-RTP4 Stand-Alone Unit
Allen-Bradley | Remote Termination Panel 1771-RTP4 Stand-Alone Unit

Allen-Bradley | Remote Termination Panel 1771-RTP4 Stand-Alone Unit


Only 10 left - Selling fast

PRODUCT SKU : 1771-RTP4

PRODUCT TYPE : Remote Termination Panel

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The Allen-Bradley 1771-RTP4 is a Remote Termination Panel designed to interface with up to 8 I/O modules, supporting both current and voltage input signals. It includes a dedicated wiring arm and requires a specified fuse for safe operation. The compact stand-alone design allows for flexible deployment in control systems while maintaining proper electrical isolation and signal integrity.

Technical Specifications

  • Manufacturer: Allen-Bradley (Rockwell Automation)

  • Model Number: 1771-RTP4

  • Product Type: Remote Termination Panel

  • Series: 1771 I/O Modules

  • Number of I/O Modules Supported: 8

  • Electrical Features:

    • Supports current inputs

    • Supports voltage inputs with resistor

    • Cold-junction compensation: Not included

    • Frequency: 47–63 Hz

    • Fuse: 3 A, 250 V, normal blow

  • Cabling and Wiring:

    • Remote cabling: 1771-PSCC, 5.5 ft

    • Wiring arm: 1771-WF

  • Physical Dimensions: 115 × 317 × 160 mm (4.5 × 12.4 × 6.3 in)

  • Weight: 0.2 kg (0.5 lb)

  • Mounting/Location: Stand-alone or panel mount compatible

Application Scenarios

The 1771-RTP4 panel is ideal for:

  • Centralizing I/O wiring for multiple 1771 modules

  • Providing a clean interface for current and voltage signal connections

  • Stand-alone or rack-mounted I/O deployments

  • Systems requiring safe and organized I/O terminations

FAQ

Q: How many I/O modules can the 1771-RTP4 support?
A: It supports up to 8 I/O modules.

Q: Can it handle both current and voltage input signals?
A: Yes, it supports current inputs directly and voltage inputs with a resistor.

Q: What is the recommended fuse for this panel?
A: A 3 A, 250 V normal-blow fuse is required for proper operation.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding VFD Mechanical Brake Logic and Control in Industrial Automation

Understanding VFD Mechanical Brake Logic and Control in Industrial Automation

Variable Frequency Drives (VFDs) play a crucial role in modern industrial automation by controlling motor speed, torque, and acceleration. However, high-inertia loads and vertical lifting systems require precise mechanical braking logic to ensure operational safety and prevent equipment damage.

Read more
Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Why Programmable Logic Controllers Drop into Stop Mode: An Expert Analysis

Industrial automation systems rely heavily on Programmable Logic Controllers (PLCs) to maintain uninterrupted production. When a PLC unexpectedly shifts from Run to Stop mode, whole manufacturing lines stall.

As control systems evolve across modern factory automation, understanding the root causes of these interruptions helps engineers minimize costly downtime. This technical guide breaks down why PLCs trip into Stop mode and provides practical strategies to mitigate system faults.

Read more
Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Understanding Root Causes of Unplanned PLC Stop Mode in Industrial Automation

Modern Programmable Logic Controllers manage execution through distinct operational states: Run, Stop, Start-Up, and Hold. During power-up, a controller initializes memory registers within Stop mode before briefly transitioning to Start-Up mode. During this phase, internal self-diagnostics evaluate system integrity across hardware and user programs. If the controller detects no critical faults, it enters Run mode to execute the control program continuously. However, any severe system anomaly forces the CPU back into Stop mode immediately to prevent erratic machine behavior across the plant floor.

Read more