PRODUCT SKU : 1794-IE8H

PRODUCT TYPE : HART Analog Input Module

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The Allen Bradley Flex I/O 1794 Series 1794-IE8H is an 8-point analog input module designed for HART-enabled applications. It delivers high-resolution signal conversion, configurable data formats, and robust diagnostic indicators. With DIN rail mounting and compatibility with Flex I/O terminal bases, this module provides reliable integration into distributed control systems.

Technical Specifications

  • Manufacturer: Allen Bradley

  • Product Line: Flex I/O 1794

  • Catalog Number / Model: 1794-IE8H

  • UPC: 612598323883

  • Product Type: Flex I/O HART Analog Module

  • Weight: 0.31 lbs (0.14 kg)

  • Resolution: 16-bit

  • Conversion Method: Successive approximation

  • Inputs: 8 single-ended, non-isolated channels

  • Absolute Accuracy: ±0.1% full scale at 20 °C (68 °F)

  • Temperature Drift: ±0.05% full scale from 0–55 °C (32–131 °F)

  • Step Response (to 99%): 80 ms

  • Terminal Base Compatibility: 1794-TB3G, 1794-TB3GS

  • Indicators:

    • 8 red fault LEDs

    • 8 yellow channel LEDs

    • 1 green power LED

  • External DC Supply: Nominal 24 VDC

  • Supply Range: 19.0–31.2 VDC (with 5% AC ripple)

  • FlexBus Current Draw: 80 mA @ 5 VDC

  • Functional Data Range: >17 V @ 22 mA

  • Isolation Voltage: 50 V continuous

  • Power Dissipation: 3.9 W max @ 31.2 VDC

  • Thermal Dissipation: 13.5 BTU/hr max @ 31.2 VDC

  • Mounting: DIN rail

  • Enclosure Type: Open-style

Application Scenarios

  • Distributed control systems requiring HART-enabled analog input

  • Process industries with multiple sensor integration

  • Environments needing diagnostic indicators for fault detection

FAQ

Q: How many analog inputs does the 1794-IE8H support?  A: Eight single-ended, non-isolated inputs.

Q: What terminal bases are compatible with this module?  A: 1794-TB3G and 1794-TB3GS.

Q: Does the module provide diagnostic indicators?  A: Yes, it includes fault, channel, and power LEDs.

Comparison with Similar Models

  • 1794-IE8H: 8-channel HART analog input, 16-bit resolution.

  • 1794-IE4XOE2: Combination analog input/output module.

  • 1794-IF8: 8-channel analog input without HART functionality.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Transforming Shop Floor Data into Actionable Insights: A Deep Dive into MES

Transforming Shop Floor Data into Actionable Insights: A Deep Dive into MES

Manufacturing Execution Systems serve as the digital backbone of modern factory floors. Positioned at Level 3 of the ISA-95 automation pyramid, MES links enterprise resource planning with real-time shop floor control systems. Today, industrial operators rely on MES software to bridge operational strategy with physical production execution.

Read more
Managed Switch vs. Unmanaged Switch: Industrial Ethernet Architecture

Managed Switch vs. Unmanaged Switch: Industrial Ethernet Architecture

Industrial Ethernet forms the backbone of factory automation. Selecting the right switch architecture determines system uptime, data throughput, and OT cyber resilience. This technical guide evaluates managed vs. unmanaged switches, analyzing operational differences, security controls, and selection criteria.
Read more
Hot Standby vs. Cold Standby Redundancy in Industrial Automation

Hot Standby vs. Cold Standby Redundancy in Industrial Automation

System availability determines process safety and productivity in industrial automation. Control engineers deploy redundancy to eliminate single points of failure. This technical guide evaluates Hot Standby vs. Cold Standby architectures, comparing failover speeds, memory sync, cost trade-offs, and field selection criteria.

Read more