Skip to content

What are you looking for?


You may also like

Allen-Bradley ControlLogix | 1756-HIST2G | FactoryTalk Historian Machine Edition ModuleAllen-Bradley ControlLogix | 1756-HIST2G | FactoryTalk Historian Machine Edition ModuleAllen-Bradley ControlLogix | 1756-HIST2G | FactoryTalk Historian Machine Edition Module
Allen-Bradley ControlLogix | 1756-HIST2G | FactoryTalk Historian Machine Edition Module
Allen-Bradley ControlLogix | 1756-HIST2G | FactoryTalk Historian Machine Edition Module
Allen-Bradley ControlLogix | 1756-HIST2G | FactoryTalk Historian Machine Edition Module

Allen-Bradley ControlLogix | 1756-HIST2G | FactoryTalk Historian Machine Edition Module


Only 10 left - Selling fast

PRODUCT SKU : 1756-HIST2G

PRODUCT TYPE : Historian Module

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

Allen-Bradley FactoryTalk Historian ME – Model: 1756-HIST2G  The 1756-HIST2G is a historian module for the Allen-Bradley ControlLogix platform, designed to capture, store, and manage time-series process data directly within automation systems. It integrates seamlessly with FactoryTalk Historian Machine Edition, providing localized data collection and analysis for improved system visibility and performance monitoring.

Technical Specifications

  • Manufacturer: Allen-Bradley (Rockwell Automation)

  • Product Line: ControlLogix

  • Model: 1756-HIST2G

  • Type: Historian Module

  • Power Consumption: 5 W typical, 7 W max

  • Communication Port: 1 Ethernet 10/100T IEEE 802.3

  • Processor: AMD LX800, 500 MHz x86 architecture

  • System Memory: Integrated historian memory

  • Battery: Rechargeable lithium, non-removable

  • Battery-Backed Memory: 512 KB SRAM

  • Cache Memory: 128 KB L1 / 128 KB L2

  • Compact Flash Support: Type 2 with DMA

  • Clock: Precision real-time clock

  • Indicators: Status LEDs and 4-character alphanumeric display

  • Weight: 1.88 lbs (0.85 kg)

Application Scenarios

  • Localized historian data collection for ControlLogix systems

  • Process monitoring and performance tracking in manufacturing environments

  • Integration with FactoryTalk Historian SE for enterprise-level data management

  • Applications requiring reliable time-series data storage with real-time clock accuracy

FAQ

Q: What is the primary function of the 1756-HIST2G?  A: It collects and stores time-series process data within ControlLogix systems.

Q: What type of communication port is available?  A: One Ethernet 10/100T IEEE 802.3 port.

Q: Does the module include a battery?  A: Yes, it has a non-removable rechargeable lithium battery.

Q: What type of memory expansion is supported?  A: Compact Flash Type 2 with DMA.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Dry Contacts in PLC Wiring: An Industrial Automation Guide

Understanding Dry Contacts in PLC Wiring: An Industrial Automation Guide

Mastering contact switching principles is essential for reliable control panels. Field devices and PLCs interface through dry or wet contacts. This technical guide examines the mechanics of dry contacts, explores their wiring architectures, and evaluates their key advantages in industrial automation.

Read more
Ultimate Commissioning Checklist for Industrial Automation Systems: An Engineering Guide

Ultimate Commissioning Checklist for Industrial Automation Systems: An Engineering Guide

Commissioning is the most decisive phase of an industrial automation project, transforming control hardware and software into an operational facility. Thorough testing prevents costly startup delays and builds customer confidence. This guide covers essential checklists, electrical standards, and best practices.

Read more
Redundant Automation Systems: Core Architecture, Business Value, and Technical Advantages

Redundant Automation Systems: Core Architecture, Business Value, and Technical Advantages

Unplanned downtime poses a major financial threat to process manufacturing. To prevent costly interruptions, engineers deploy redundant PLC and DCS architectures that ensure continuous operation when hardware fails. This technical guide explores redundancy principles, critical system nodes, and real-world scenarios.

Read more