Skip to content

What are you looking for?


You may also like

Allen-Bradley 81004-286-52-R PowerFlex 7000 400A SGCT Assembly Matched PairAllen-Bradley 81004-286-52-R PowerFlex 7000 400A SGCT Assembly Matched PairAllen-Bradley 81004-286-52-R PowerFlex 7000 400A SGCT Assembly Matched Pair
Allen-Bradley 81004-286-52-R PowerFlex 7000 400A SGCT Assembly Matched Pair
Allen-Bradley 81004-286-52-R PowerFlex 7000 400A SGCT Assembly Matched Pair
Allen-Bradley 81004-286-52-R PowerFlex 7000 400A SGCT Assembly Matched Pair

Allen-Bradley 81004-286-52-R PowerFlex 7000 400A SGCT Assembly Matched Pair


Only 10 left - Selling fast

PRODUCT SKU : 81004-286-52-R

PRODUCT TYPE : SGCT Assembly

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The 81004-286-52-R functions as a critical power semiconductor component specifically for the Allen-Bradley PowerFlex 7000 Medium Voltage (MV) Drive. This 400A Symmetrical Gate Commutated Thyristor (SGCT) assembly comes as a Matched Pair to ensure balanced current distribution and synchronized switching across the drive's power modules. It manages high-power switching states to maintain precise motor control and energy efficiency in heavy-duty industrial applications. We supply this assembly in 100% Brand New condition, meeting the stringent electrical tolerances required for medium voltage power electronics.

Technical Specifications

  • Component Type: 400A SGCT Assembly (Symmetrical Gate Commutated Thyristor)

  • Configuration: Matched Pair (Two synchronized units)

  • Application Compatibility: PowerFlex 7000 Medium Voltage Drives

  • Amperage Rating: 400 Amps

  • Category: Drive Power Electronics / Circuit Board

  • Shipping Weight: 4.70 lbs (2.13 kg)

  • Drive Voltage Class: Medium Voltage (MV)

Engineering Advantages

The 81004-286-52-R solves high-power conversion challenges through precision matching and robust thermal engineering:

  • Synchronized Switching Performance: The "Matched Pair" designation ensures that both SGCTs exhibit nearly identical electrical characteristics. This synchronization prevents uneven current sharing, which typically leads to localized overheating and premature failure of the power bridge.

  • Optimized Power Density: The 400A rating provides the necessary thermal and electrical headroom for high-torque applications. The assembly maintains low switching losses, reducing the overall heat load on the drive's liquid or air-cooling system.

  • Direct Integration for MV Systems: This board integrates seamlessly into the existing PowerFlex 7000 gate driver architecture. Its mechanical layout ensures a secure fit within the power cell, facilitating high-pressure contact required for effective current transfer and heat dissipation.

  • Enhanced Drive Uptime: Replacing worn power semiconductors with Brand New matched assemblies eliminates the unpredictability of used or mismatched components. This proactive approach prevents catastrophic drive "faults" and ensures the longevity of the entire inverter section.

FAQs

  • Why must I replace these as a "Matched Pair"?

    Medium voltage drives require balanced electrical loads across all phases. If you install mismatched SGCTs, one unit may carry more current than the other, triggering overcurrent faults or damaging the power module due to thermal stress.

  • Is this part suitable for both air-cooled and liquid-cooled PowerFlex 7000 drives?

    The 81004-286-52-R primarily serves the 400A power structures found in PowerFlex 7000 frames. Always verify your drive's specific amperage and frame size against the technical manual to ensure compatibility.

  • What precautions should I take during installation?

    Power electronics require strict adherence to torque specifications for mounting to the heatsink. Use a calibrated torque wrench and follow ESD (Electrostatic Discharge) safety protocols to prevent damaging the sensitive gate circuitry on the board.

  • Is this a Brand New original component?

    Yes. We guarantee this 81004-286-52-R is 100% Brand New and original. In medium voltage applications, using new semiconductors is vital because internal degradation often remains invisible until the system operates under full load.

 

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Mastering VFD Braking Theory and Mechanical Brake Sequencing in Industrial Automation

Mastering VFD Braking Theory and Mechanical Brake Sequencing in Industrial Automation

In industrial automation, variable frequency drives (VFDs) regulate motor speed and torque across manufacturing plants and material handling systems. However, certain heavy-duty applications experience external loads that can rotate the motor shaft without an active command. For instance, gravity pulls loads downward in unanchored hoisting equipment. Therefore, engineers integrate mechanical brakes with VFD logic to maintain absolute safety and prevent structural damage or personnel injury during shutdowns.

Read more
Optimizing Tank Level Control Using Proportional Algorithms in PLC Systems

Optimizing Tank Level Control Using Proportional Algorithms in PLC Systems

Industrial automation engineers frequently encounter liquid level regulation challenges across diverse process plants. Traditional ON-OFF control mechanisms often disrupt system stability due to abrupt actuator switching. Therefore, upgrading to closed-loop architectures like proportional control yields smoother responses. In a typical PLC environment, such as Siemens TIA Portal, engineers utilize closed-loop feedback to minimize process errors without requiring full PID complexity.

Read more
Understanding Why Your PLC Enters Stop Mode: Causes and Troubleshooting

Understanding Why Your PLC Enters Stop Mode: Causes and Troubleshooting

In industrial automation, programmable logic controllers (PLCs) serve as the core intelligence of modern factory automation and distributed control systems (DCS). Understanding how a PLC transitions between modes is vital for maintenance engineers. Typically, a PLC operates across four primary modes: Run, Stop, Start-Up, and Hold. When power is applied, the system immediately boots into Stop mode before initiating the Start-Up sequence. If the controller encounters a critical error during execution, it automatically reverts to Stop mode to prevent equipment damage. Therefore, monitoring these state transitions helps technicians maintain high system availability.

Read more