Skip to content

What are you looking for?


You may also like

Allen-Bradley 2711P-B10C6D1 PanelView Plus 1000 Color Keypad/Touch Operator TerminalAllen-Bradley 2711P-B10C6D1 PanelView Plus 1000 Color Keypad/Touch Operator TerminalAllen-Bradley 2711P-B10C6D1 PanelView Plus 1000 Color Keypad/Touch Operator Terminal
Allen-Bradley 2711P-B10C6D1 PanelView Plus 1000 Color Keypad/Touch Operator Terminal
Allen-Bradley 2711P-B10C6D1 PanelView Plus 1000 Color Keypad/Touch Operator Terminal
Allen-Bradley 2711P-B10C6D1 PanelView Plus 1000 Color Keypad/Touch Operator Terminal

Allen-Bradley 2711P-B10C6D1 PanelView Plus 1000 Color Keypad/Touch Operator Terminal


Only 10 left - Selling fast

PRODUCT SKU : 2711P-B10C6D1

PRODUCT TYPE : Operator Terminal

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The Allen-Bradley 2711P-B10C6D1 serves as a high-performance Human-Machine Interface (HMI) within the legacy PanelView Plus 1000 operator terminal series. This visualization platform bridges the gap between floor operators and complex automated systems, rendering real-time process diagnostics, alarm telemetry, and machine control parameters.

While the original manufacturer labels this hardware series as discontinued and obsolete, we supply this critical industrial asset exclusively as a 100% brand new, original factory-sealed unit. This ensures a completely pristine LCD panel matrix, unblemished tactile micro-switches, and a fresh internal backup capacitor array ready for immediate deployment on legacy production networks.

Technical Specifications

The table below displays the complete mechanical, electrical, and data communication profile for the 2711P-B10C6D1 operator terminal:

Parameter Industrial System Configuration & Rating
Manufacturer Allen-Bradley / Rockwell Automation
Part Number 2711P-B10C6D1
Product Family PanelView Plus Operator Terminals
Display Size & Type 10.4-inch Color Active Matrix Thin-Film精神 Transistor (TFT) LCD
Active Display Area 210 x 131 mm (8.27 x 5.17 in.)
Native Resolution 640 x 400 Pixels
Backlight Mechanism Ultra-Long-Life LED Backlight (100,000 Hours Lifespan)
Operator Input Configuration Dual Modality: Keypad & Analog Resistive Touchscreen
Mechanical Keypad Layout 32 Action Keys (F1-F16, K1-K16), Numeric (0-9), System Navigation
Keypad Durability Rating Tested up to 1 Million Actuations
Internal Memory Profile 64 MB Total Memory / 32 MB Flash & 32 MB RAM
Integrated Communication Interfaces Data Highway Plus (DH+), Remote I/O (RIO), DH-485, RS-232, Ethernet, USB
Dedicated Network Cables Belden 1770-CD (RIO/DH+) / 1761-CBL-ASO3 (DH-485)
Hardware Series Compatibility Series A, B, C, D, and F Support
Input DC Operating Power 18 to 32V DC Nominal Field Power Input
Net Hardware Weight 7.00 lbs (3.18 kg)

Engineering Advantages

  • Dual Interface Mode Ensures Constant Field Availability: This unit combines an analog resistive touchscreen with a 32-button mechanical membrane keypad. When operators wear thick, chemical-resistant safety gloves that degrade typical touchscreen accuracy, the physical dome switches provide definite tactile feedback. This redundant input path guarantees continuous control even if flying debris punctures or scratches the top resistive screen layer.

  • Simplifies Legacy RIO and DH+ Infrastructure Migrations: The communication expansion footprint houses onboard processing chips for Remote I/O (RIO) and Data Highway Plus (DH+) communication. Plant engineers do not need to rewrite complex control rungs, replace thousands of feet of existing blue-hose network cable, or install external gateway converters when swapping out a damaged field terminal.

  • Resists Extreme Control Panel Moisture Puncture: High-durometer compression gaskets seal the perimeter edge of the screen frame. When clamped into a standard cabinet cutout, this sealing boundary blocks airborne dust particles, vaporized machine coolant, and low-pressure water washdown sprays from bypassing the cutout and short-circuiting the sensitive internal circuit board architecture.

FAQs

  • Can this terminal run newer FactoryTalk View ME runtime files directly?

    The 2711P-B10C6D1 natively supports runtime files engineered for the original PanelView Plus framework. When migrating older systems using FactoryTalk View Studio software, you must compile the application file (.APA) into a specific legacy runtime format (.MER) that matches the internal operating system limits of this terminal before transferring data via the RS-232 or Ethernet ports.

  • How does the 100,000-hour LED backlight affect continuous operations?

    The solid-state LED backlight eliminates the high-voltage inverter assemblies found in older cold-cathode fluorescent lamp (CCFL) terminals. This design cuts panel heat generation inside the HMI housing, maintains bright, crisp color contrast across a 100,000-hour runtime curve, and stops the screen flickering caused by failing high-voltage backplane components.

  • What are the key wiring precautions during the final panel installation?

    The power supply terminal accept a broad DC range spanning from 18V DC up to 32V DC. Technicians must route the DC power feeds inside a separate conduit away from high-current AC motor leads, and they must land a dedicated ground wire onto the functional earth ground lug to shield the communication channels from electromagnetic common-mode noise.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Modern manufacturing relies heavily on automated control systems to maximize throughput and maintain product quality. However, unplanned downtime in industrial automation can cost facility operators thousands of dollars per hour. Understanding how programmable logic controllers (PLCs), distributed control systems (DCS), and field instrumentation fail empowers engineering teams to implement robust preventive maintenance strategies.

Read more
Essential Motion Control Commands: A Practical Guide for Engineers

Essential Motion Control Commands: A Practical Guide for Engineers

Automation engineers often rely on precise position and speed control to drive modern factory machinery. Modern industrial systems, such as Programmable Logic Controllers (PLCs) and Distributed Control Systems (DCS), depend heavily on standardized motion instructions. Mastering these commands ensures operational safety, protects mechanical components, and optimizes cycle times across production lines.

Read more
The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

Implementing robust protection in hazardous industrial environments represents a fundamental safety requirement in factory automation. Process facilities often handle volatile gases, dusts, and chemical agents that pose significant combustion risks. Consequently, control system engineers must deploy energy-limiting interfaces to isolate safe-area control cabinets from hazardous-area field instrumentation. This article examines the function, selection, and electrical principles of intrinsic safety barriers within modern PLC and DCS networks.

Read more