PRODUCT SKU : 1771-IL

PRODUCT TYPE : Analog Input Module

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The Allen Bradley 1771-IL is an isolated analog input module designed for legacy PLC-5 systems. It provides eight fully isolated differential channels, supporting both voltage and current input ranges. With high accuracy, auto-calibration, and robust isolation, this module ensures precise signal acquisition in demanding industrial environments.

Technical Specifications

  • Manufacturer Allen Bradley

  • Product Line PLC-5 Series

  • Module Type Analog Input Module

  • Part Number 1771-IL

  • Number of Inputs 8 isolated differential channels

  • Input Voltage Ranges +1 to +5 V DC, 0 to +5 V DC, ±5 V DC, ±10 V DC

  • Input Current Ranges +4 to +20 mA, 0 to +20 mA, ±20 mA

  • Resolution 16-bit binary across full range

  • Accuracy (Voltage) Typical 0.01%, Max 0.05% @ 25 °C

  • Accuracy (Current) Typical 0.06%, Max 0.1% @ 25 °C

  • Backplane Current 1.3 A

  • Data Format Natural Binary or BCD

  • Channel Update Time 500 ms for 8 channels

  • Internal Scan Rate 50 ms

  • Chassis Compatibility All 1771 I/O chassis

  • Wiring Arm 1771-WG

  • Mounting 1-slot rack mountable

  • Isolation 1000 V between channels

  • Functional Highlights Auto-calibration, jumper-selectable voltage/current mode, open-circuit detection, overvoltage protection, block transfer instructions (BTW/BTR), LED indicators for diagnostics

Application Scenarios

  • Precision analog signal acquisition in legacy PLC-5 systems

  • Industrial processes requiring isolated differential inputs

  • Environments where high accuracy and robust isolation are critical

FAQ

Q: How many channels does the 1771-IL provide?  A: It supports 8 fully isolated differential input channels.

Q: What input ranges are supported?  A: Voltage ranges include ±10 V, ±5 V, 0–5 V, and +1–5 V. Current ranges include 0–20 mA, +4–20 mA, and ±20 mA.

Q: Is the module compatible with all PLC-5 chassis?  A: Yes, it can be installed in any 1771 I/O chassis.

Q: How often should calibration be performed?  A: Auto-calibration is integrated, but periodic verification is recommended for critical applications.

Comparable Models

  • 1771-IL: 8-channel isolated analog input module (this model)

  • 1771-IFE: Non-isolated analog input module for standard applications

  • 1771-IR: Resistance input module for specialized sensor measurements

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Dry Contacts in PLC Wiring: An Industrial Automation Guide

Understanding Dry Contacts in PLC Wiring: An Industrial Automation Guide

Mastering contact switching principles is essential for reliable control panels. Field devices and PLCs interface through dry or wet contacts. This technical guide examines the mechanics of dry contacts, explores their wiring architectures, and evaluates their key advantages in industrial automation.

Read more
Ultimate Commissioning Checklist for Industrial Automation Systems: An Engineering Guide

Ultimate Commissioning Checklist for Industrial Automation Systems: An Engineering Guide

Commissioning is the most decisive phase of an industrial automation project, transforming control hardware and software into an operational facility. Thorough testing prevents costly startup delays and builds customer confidence. This guide covers essential checklists, electrical standards, and best practices.

Read more
Redundant Automation Systems: Core Architecture, Business Value, and Technical Advantages

Redundant Automation Systems: Core Architecture, Business Value, and Technical Advantages

Unplanned downtime poses a major financial threat to process manufacturing. To prevent costly interruptions, engineers deploy redundant PLC and DCS architectures that ensure continuous operation when hardware fails. This technical guide explores redundancy principles, critical system nodes, and real-world scenarios.

Read more