Skip to content

What are you looking for?


You may also like

Allen-Bradley 1756-IT6I2 ControlLogix 6-Channel Isolated Thermocouple Input ModuleAllen-Bradley 1756-IT6I2 ControlLogix 6-Channel Isolated Thermocouple Input ModuleAllen-Bradley 1756-IT6I2 ControlLogix 6-Channel Isolated Thermocouple Input Module
Allen-Bradley 1756-IT6I2 ControlLogix 6-Channel Isolated Thermocouple Input Module
Allen-Bradley 1756-IT6I2 ControlLogix 6-Channel Isolated Thermocouple Input Module
Allen-Bradley 1756-IT6I2 ControlLogix 6-Channel Isolated Thermocouple Input Module

Allen-Bradley 1756-IT6I2 ControlLogix 6-Channel Isolated Thermocouple Input Module


Only 10 left - Selling fast

PRODUCT SKU : 1756-IT6I2

PRODUCT TYPE : Analog I/O Module

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The 1756-IT6I2 is a high-performance analog input module designed for the ControlLogix platform, specifically engineered for precision temperature sensing in demanding industrial environments. This enhanced module features six independently isolated thermocouple inputs, providing superior noise immunity and preventing ground loop interference between channels. It also includes two onboard Cold Junction Compensation (CJC) sensors to ensure high-accuracy readings across a wide ambient temperature range.

With a 16-bit resolution architecture, the 1756-IT6I2 (Part Number: 1756-IT6I2) supports a comprehensive array of sensor types and millivolt ranges. It is optimized for speed and flexibility, offering multiple data formats including 32-bit floating point for direct engineering unit representation. The module's robust design draws power from the 1756 backplane and is compatible with standard or spring-clamp removable terminal blocks for secure field wiring.

Technical Specifications

  • Module Type: Isolated Thermocouple/Millivolt Input

  • Number of Channels: 6 Isolated Inputs; 2 CJC points

  • Supported Thermocouples: Types B, C, D, E, J, K, L, N, R, S, T

  • Resolution: 16-bit (0.7 $\mu$V/bit in high-resolution mode)

  • Millivolt Ranges: -12 to 30 mV or -12 to 78 mV

  • Module Scan Time: 25ms (Floating point millivolt); 50ms (Temperature); 10ms (Integer)

  • Backplane Current (5V DC): 200 mA

  • Backplane Current (24V DC): 120 mA

  • Power Dissipation: 4.6 Watts (Maximum)

  • Data Formats: IEEE 32-bit Floating Point; Integer Mode (2s complement)

  • Required RTB: 1756-TBNH or 1756-TBSH

  • Isolation Voltage: Channel-to-channel and channel-to-backplane isolation

  • Shipping Weight: 0.28 kg (0.63 lbs)

Application and System Comparison

The 1756-IT6I2 is the preferred choice over standard non-isolated modules (like the 1756-IR6I) for applications where thermocouples are attached to different metal structures with varying electrical potentials. This isolation is critical in preventing signal distortion in smelting, heat-treating, and chemical processing. The "Enhanced" designation reflects its improved processing speed and expanded thermocouple type support compared to first-generation Logix modules.

Engineering FAQ

What is the benefit of the two CJC sensors in this module?

The 1756-IT6I2 utilizes two CJC sensors to better average the temperature across the terminal block. This compensates for thermal gradients caused by heat dissipation within the chassis, ensuring the reference junction temperature is accurately calculated for all six channels.

Can I mix different thermocouple types on the same module?

Yes. Each of the six isolated channels on the 1756-IT6I2 can be individually configured in the Studio 5000 software to a specific sensor type or millivolt range, providing maximum flexibility for varied process requirements.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

FAT vs SAT in Industrial Control Systems: Key Differences and Execution Guide

Industrial control system deployment relies on strict verification protocols to guarantee operational safety, system stability, and regulatory compliance. Commissioning complex Programmable Logic Controller (PLC) racks, Distributed Control Systems (DCS), and Safety Instrumented Systems (SIS) requires two critical milestones: the Factory Acceptance Test (FAT) and the Site Acceptance Test (SAT). Both procedures validate that system automation meets design specifications, but they occur at different stages of project execution and target distinct operational risks.

Read more
Hub vs Switch vs Router in Industrial Automation Architecture

Hub vs Switch vs Router in Industrial Automation Architecture

Modern factory automation relies on reliable industrial networking infrastructure to exchange real-time field data across operational technology systems. Engineers often encounter networking hardware like hubs, switches, and routers when integrating Programmable Logic Controllers, Distributed Control Systems, and SCADA monitoring nodes. Although these devices share physical ports, they operate at different layers of the Open Systems Interconnection reference model and deliver distinct traffic management capabilities.

Read more
Marshalling Cabinet Preventive Maintenance: Essential Healthiness Checks for PLC, DCS, and ESD Systems

Marshalling Cabinet Preventive Maintenance: Essential Healthiness Checks for PLC, DCS, and ESD Systems

Marshalling cabinets serve as the vital interface between field instrumentation and control room electronics in modern process facilities. Regular preventive maintenance of these cabinets ensures signal integrity across programmable logic controllers (PLCs), distributed control systems (DCS), and emergency shutdown (ESD) networks. System technicians must execute structured inspection protocols to mitigate environmental risks, identify loose wiring, and maintain continuous operational readiness.

Read more