Skip to content

What are you looking for?


You may also like

Allen-Bradley 1756-BATM ControlLogix Externally Mounted Battery Assembly KitAllen-Bradley 1756-BATM ControlLogix Externally Mounted Battery Assembly KitAllen-Bradley 1756-BATM ControlLogix Externally Mounted Battery Assembly Kit
Allen-Bradley 1756-BATM ControlLogix Externally Mounted Battery Assembly Kit
Allen-Bradley 1756-BATM ControlLogix Externally Mounted Battery Assembly Kit
Allen-Bradley 1756-BATM ControlLogix Externally Mounted Battery Assembly Kit

Allen-Bradley 1756-BATM ControlLogix Externally Mounted Battery Assembly Kit


Only 10 left - Selling fast

PRODUCT SKU : 1756-BATM

PRODUCT TYPE : Externally Mounted Battery Assembly Kit

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The 1756-BATM serves as an externally mounted, high-capacity lithium battery assembly designed for the Allen-Bradley ControlLogix platform. This kit provides extended back-up power to the controller's non-volatile memory, safeguarding critical ladder logic, tag data, and system configurations during total power loss. It specifically supports high-demand L55 and L6x series processors that require longer hold-up times than standard internal batteries can provide. We supply this unit as 100% Brand New and factory-original, ensuring maximum chemical shelf-life and voltage stability for your automation assets.

Technical Specifications

The 1756-BATM utilizes high-energy-density lithium chemistry to maintain a stable voltage rail across extended durations.

Feature Specification
Battery Type Lithium (Non-Rechargeable)
Voltage Output 3.6V DC
Current Capacity 17,000 mAh (17 Ah)
Mounting Format External (Chassis/Panel Mount)
Compatibility ControlLogix 1756-L5x and 1756-L6x Controllers
Connection 1756-BATT Cable Interface
Weight 2.36 lbs (1.07 kg)
Status Discontinued by Manufacturer (Available as New Stock)

Engineering Advantages

  • Extreme Hold-Up Duration: With a 17,000 mAh capacity, the 1756-BATM offers significantly higher energy reserves compared to the standard 1756-BA1 or BA2 internal cells. This solves the industrial pain point of frequent battery depletion in facilities that experience long-term seasonal shutdowns.

  • External Mounting Safety: This kit mounts externally to the controller, typically on the side of the chassis. This positioning facilitates easier maintenance and replacement without requiring the technician to reach into the internal processor housing, reducing the risk of accidental electrostatic discharge (ESD) to the CPU.

  • Deep Memory Protection: The assembly maintains the RAM state for large-scale programs in high-performance L63 or L64 controllers. It ensures that the processor retains its state and avoids "dead battery" faults that lead to cleared memory and costly re-downloading procedures.

  • Rugged Housing: The assembly features a specialized protective enclosure that shields the lithium cells from the vibration and mechanical shocks common in industrial machine cabinets, ensuring continuous electrical contact.

FAQs

  • Does the 1756-BATM replace the internal battery?

    Yes. When you install the 1756-BATM, you disconnect the internal battery and plug the 1756-BATM cable into the processor's battery connector. This provides a much larger capacity reservoir for memory backup.

  • How often should I replace the 1756-BATM?

    While the 17,000 mAh capacity lasts much longer than standard batteries, we recommend replacement every 2 to 3 years depending on the duration of power-off periods. Always check the "BATT" LED indicator on the ControlLogix processor; a red LED signals that you must replace the kit immediately.

  • Is this a "Fresh" battery kit?

    Yes. Despite the manufacturer's discontinued status, we guarantee our 1756-BATM kits are 100% Brand New original stock. We monitor our inventory to ensure that the lithium cells maintain their nominal 3.6V output, preventing the "voltage dip" common in used or improperly stored surplus.

  • What happens if the battery dies while the PLC is powered on?

    If the PLC remains powered by the 1756-PA72 or PB72 power supply, the controller will function normally but will trigger a "Battery Low" minor fault. The data is only at risk if the main power is lost while the battery is depleted.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Static UPS vs. Rotary UPS: Technical Evaluation for Industrial Automation

Static UPS vs. Rotary UPS: Technical Evaluation for Industrial Automation

UPS architecture dictates power reliability in process automation. Unplanned voltage sags cause immediate downtime, making robust power backup essential for PLC and DCS networks. This technical guide evaluates the operational principles, key architectures, and tradeoffs between Static and Dynamic Rotary UPS systems.
Read more
Comprehensive Guide to Noise Types in Industrial Automation and Electronics

Comprehensive Guide to Noise Types in Industrial Automation and Electronics

Signal integrity determines reliability in modern industrial automation. Unwanted electrical noise degrades sensor data, distorts 4-20 mA current loops, and drops fieldbus communications. Engineers working with PLC, DCS, and TSI systems must effectively mitigate these disturbances. This technical guide analyzes key internal and external noise sources affecting control systems.
Read more
Mitigating Emergency Stop Spurious Trips in Industrial Control Systems

Mitigating Emergency Stop Spurious Trips in Industrial Control Systems

Emergency stop (E-Stop) pushbuttons serve as vital safety devices in factory automation and process control plants. Functional safety standards mandate normally-closed (NC) contact blocks to ensure fail-safe operation during wiring breaks or power outages. However, mechanical degradation over time can trigger unexpected spurious trips, halting production lines without an actual emergency. Understanding the underlying causes of mechanical contact failure allows automation engineers to implement robust, fault-tolerant safety circuits.

Read more