Skip to content

What are you looking for?


You may also like

Allen-Bradley 1732E-8CFGM8R | ArmorBlock 8-Point Configurable I/O ModuleAllen-Bradley 1732E-8CFGM8R | ArmorBlock 8-Point Configurable I/O ModuleAllen-Bradley 1732E-8CFGM8R | ArmorBlock 8-Point Configurable I/O Module
Allen-Bradley 1732E-8CFGM8R | ArmorBlock 8-Point Configurable I/O Module
Allen-Bradley 1732E-8CFGM8R | ArmorBlock 8-Point Configurable I/O Module
Allen-Bradley 1732E-8CFGM8R | ArmorBlock 8-Point Configurable I/O Module

Allen-Bradley 1732E-8CFGM8R | ArmorBlock 8-Point Configurable I/O Module


Only 10 left - Selling fast

PRODUCT SKU : 1732E-8CFGM8R

PRODUCT TYPE : Configurable I/O Module

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Description

The Allen-Bradley 1732E-8CFGM8R ArmorBlock module is a compact, configurable I/O device designed for distributed control in harsh industrial environments. It provides eight input channels and eight output channels, supporting sink-type inputs and sourcing-type outputs. With a wide operating temperature range and robust environmental ratings, this module ensures reliable performance in demanding applications.

Technical Specifications

  • Manufacturer Allen-Bradley

  • Product Line ArmorBlock 1732 Series

  • Part Number 1732E-8CFGM8R

  • Category PLCs

  • Weight 0.25 lbs (0.11 kg)

  • Inputs 8 sink-type channels

  • Outputs 8 sourcing-type channels

  • Voltage Range 12–30 V DC

  • Pilot Duty Rating DC-14

  • Maximum Off-State Voltage 5 V DC

  • Operating Temperature –4 to 140 °F (–20 to 60 °C)

  • Storage Temperature –40 to 185 °F (–40 to 85 °C)

  • Relative Humidity 5–95% non-condensing

  • Emissions Rating Group 1, Class A

  • Enclosure Type ArmorBlock rugged housing

Application Scenarios

  • Distributed machine-level control in harsh environments

  • Configurable I/O for modular automation systems

  • Applications requiring compact modules with both input and output flexibility

FAQ

  • Q: How many I/O points are available?  A: Eight inputs and eight outputs.

  • Q: What type of inputs and outputs are supported?  A: Sink-type inputs and sourcing-type outputs.

  • Q: What is the operating temperature range?  A: –4 to 140 °F (–20 to 60 °C).

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Modern manufacturing relies heavily on automated control systems to maximize throughput and maintain product quality. However, unplanned downtime in industrial automation can cost facility operators thousands of dollars per hour. Understanding how programmable logic controllers (PLCs), distributed control systems (DCS), and field instrumentation fail empowers engineering teams to implement robust preventive maintenance strategies.

Read more
Essential Motion Control Commands: A Practical Guide for Engineers

Essential Motion Control Commands: A Practical Guide for Engineers

Automation engineers often rely on precise position and speed control to drive modern factory machinery. Modern industrial systems, such as Programmable Logic Controllers (PLCs) and Distributed Control Systems (DCS), depend heavily on standardized motion instructions. Mastering these commands ensures operational safety, protects mechanical components, and optimizes cycle times across production lines.

Read more
The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

Implementing robust protection in hazardous industrial environments represents a fundamental safety requirement in factory automation. Process facilities often handle volatile gases, dusts, and chemical agents that pose significant combustion risks. Consequently, control system engineers must deploy energy-limiting interfaces to isolate safe-area control cabinets from hazardous-area field instrumentation. This article examines the function, selection, and electrical principles of intrinsic safety barriers within modern PLC and DCS networks.

Read more