Skip to content

What are you looking for?


You may also like

Allen-Bradley 140M 140-CMN-6300 Motor Protection BreakerAllen-Bradley 140M 140-CMN-6300 Motor Protection BreakerAllen-Bradley 140M 140-CMN-6300 Motor Protection Breaker
Allen-Bradley 140M 140-CMN-6300 Motor Protection Breaker
Allen-Bradley 140M 140-CMN-6300 Motor Protection Breaker
Allen-Bradley 140M 140-CMN-6300 Motor Protection Breaker

Allen-Bradley 140M 140-CMN-6300 Motor Protection Breaker


Only 10 left - Selling fast

PRODUCT SKU : 140CMN6300

PRODUCT TYPE : Motor Protection Circuit Breaker

PRODUCT VENDOR : Allen-Bradley


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Overview
The 140-CMN-6300 is a motor protection circuit breaker from Allen-Bradley’s 140M series. It provides combined overload, short-circuit, and branch-circuit protection for motors and associated circuits, ensuring safe and reliable operation across industrial environments. CE marked and CSA certified, it meets global standards for electrical safety and performance.

Technical Specifications

  • Brand & Model: Allen-Bradley 140-CMN-6300

  • Product Type: Motor Protection Circuit Breaker

  • Series: 140M Circuit Breakers

  • Max Current: 90 A

  • Trip Setting Range: 40–63 A

  • Current Rating: 16–90 A

  • Operating Voltage: 230–690 VAC

  • Short-Circuit Protection: Yes

  • Overload Protection: Thermal and Magnetic

  • Wire Size (Copper): #8–14 AWG

  • Wire Insulation Rating: 75°C

  • Standard Magnetic Trip: Yes

  • High Magnetic Trip: Yes

  • Torque: 6–10 Nm (55–90 lb-in)

  • Ultimate Short-Circuit Breaking:

    • 230/240 VAC: 50 A

    • 400/415 VAC: 20 A

    • 500 VAC: 10 A

    • 690 VAC: 4 A

  • Trip Class: 10

  • Mechanical Operations: 30,000

  • Electrical Operations (Max): 5,000

  • Magnetic Release Current: 890 A

  • Switching Frequency: 20 operations/hour

  • Rated Frequency: 40–60 Hz

  • Standards Compliance: IEC/EN 60947-1,-2, UL508, CSA C22.2 No.14

  • Weight: 4.31 lbs (1.96 kg)

Applications
Designed for motor branch circuit protection, short-circuit interruption, manual switching, and overload control. Suitable for industrial motors, pumps, and machine control panels.

FAQ

Q: What is the maximum operating voltage for the 140-CMN-6300?
A: The breaker supports voltages from 230 to 690 VAC.

Q: Does it provide short-circuit protection?
A: Yes, it offers both magnetic short-circuit and thermal overload protection.

Q: Can it handle motors up to 90 A?
A: Yes, the maximum current rating is 90 A, adjustable via the trip setting.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Modern manufacturing relies heavily on automated control systems to maximize throughput and maintain product quality. However, unplanned downtime in industrial automation can cost facility operators thousands of dollars per hour. Understanding how programmable logic controllers (PLCs), distributed control systems (DCS), and field instrumentation fail empowers engineering teams to implement robust preventive maintenance strategies.

Read more
Essential Motion Control Commands: A Practical Guide for Engineers

Essential Motion Control Commands: A Practical Guide for Engineers

Automation engineers often rely on precise position and speed control to drive modern factory machinery. Modern industrial systems, such as Programmable Logic Controllers (PLCs) and Distributed Control Systems (DCS), depend heavily on standardized motion instructions. Mastering these commands ensures operational safety, protects mechanical components, and optimizes cycle times across production lines.

Read more
The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

Implementing robust protection in hazardous industrial environments represents a fundamental safety requirement in factory automation. Process facilities often handle volatile gases, dusts, and chemical agents that pose significant combustion risks. Consequently, control system engineers must deploy energy-limiting interfaces to isolate safe-area control cabinets from hazardous-area field instrumentation. This article examines the function, selection, and electrical principles of intrinsic safety barriers within modern PLC and DCS networks.

Read more