Skip to content

What are you looking for?


You may also like

ADM11C | Yokogawa | CENTUM CS 3000 Contact Input ModuleADM11C | Yokogawa | CENTUM CS 3000 Contact Input ModuleADM11C | Yokogawa | CENTUM CS 3000 Contact Input Module
ADM11C | Yokogawa | CENTUM CS 3000 Contact Input Module
ADM11C | Yokogawa | CENTUM CS 3000 Contact Input Module
ADM11C | Yokogawa | CENTUM CS 3000 Contact Input Module

ADM11C | Yokogawa | CENTUM CS 3000 Contact Input Module


Only 10 left - Selling fast

PRODUCT SKU : ADM11C

PRODUCT TYPE : Contact Input Module

PRODUCT VENDOR : Yokogawa


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The Yokogawa ADM11C serves as a versatile digital interface for the CENTUM Distributed Control System (DCS). This module executes precise ON/OFF detection by monitoring 16 contact input points, with a scalable architecture that allows upgrades to a 32-channel configuration. It processes both dry contact and voltage inputs ranging from 4.5 to 25 V DC, ensuring seamless integration between field sensors and the central controller.

Technical Specifications

The ADM11C utilizes high-speed circuitry and robust electrical isolation to maintain data integrity:

Feature Specification
Input Points 16 Channels (Upgradable to 32)
Input Signal Type Contact Input / Voltage Input (4.5 to 25 V DC)
Response Time (Status) 8 ms
Response Time (Pushbutton) 20 ms
Current Consumption 120 mA at 24 V DC
Connection Method KS2 / KS3 Connector Cable
Signal Isolation Channel-to-channel isolation
Weight Approx. 0.58 kg
Product Condition 100% Brand New and Original

Engineering Advantages

  • Scalable I/O Architecture: The ADM11C offers a unique upgrade path from 16 to 32 channels. This flexibility allows engineers to expand system capacity as plant requirements grow without replacing the existing base hardware.

  • Superior Signal Protection: Independent channel-to-channel isolation eliminates ground loop interference and prevents localized electrical faults from propagating across the entire I/O nest. This protection significantly enhances the stability of critical process loops.

  • Rapid Installation: The connector-type interface utilizes standard KS2 or KS3 cables, replacing traditional point-to-point screw terminal wiring. This design reduces cabinet dressing time and eliminates the risk of human error during commission.

  • Dual-Mode Response Logic: Optimized firmware distinguishes between standard status inputs (8 ms) and pushbutton signals (20 ms). This prevents "contact chatter" and ensures the control system only registers intentional physical activations.

FAQs

  • Is the Yokogawa ADM11C unit provided as new or refurbished?

    We guarantee the ADM11C as 100% Brand New and Original. Every unit arrives in its original manufacturer’s packaging with factory seals intact, ensuring zero operational wear.

  • How do I upgrade the module from 16 to 32 channels?

    Expansion typically involves configuring the software parameters within the CENTUM engineering station and ensuring the wiring via KS cables supports the higher density. Please consult your specific Yokogawa system manual for firmware compatibility.

  • What is the primary benefit of the connector-type connection?

    The connector-type (ADM11C) allows for "plug-and-play" installation. It enables maintenance teams to replace the module in seconds by simply swapping the KS cable, whereas terminal-type modules require disconnecting dozens of individual wires.

  • Does this module support voltage inputs from third-party sensors?

    Yes. The ADM11C accepts voltage inputs between 4.5 and 25 V DC. This wide range accommodates standard 24V sensors as well as lower-voltage digital electronics commonly found in industrial telemetry.

 

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Transforming Shop Floor Data into Actionable Insights: A Deep Dive into MES

Transforming Shop Floor Data into Actionable Insights: A Deep Dive into MES

Manufacturing Execution Systems serve as the digital backbone of modern factory floors. Positioned at Level 3 of the ISA-95 automation pyramid, MES links enterprise resource planning with real-time shop floor control systems. Today, industrial operators rely on MES software to bridge operational strategy with physical production execution.

Read more
Managed Switch vs. Unmanaged Switch: Industrial Ethernet Architecture

Managed Switch vs. Unmanaged Switch: Industrial Ethernet Architecture

Industrial Ethernet forms the backbone of factory automation. Selecting the right switch architecture determines system uptime, data throughput, and OT cyber resilience. This technical guide evaluates managed vs. unmanaged switches, analyzing operational differences, security controls, and selection criteria.
Read more
Hot Standby vs. Cold Standby Redundancy in Industrial Automation

Hot Standby vs. Cold Standby Redundancy in Industrial Automation

System availability determines process safety and productivity in industrial automation. Control engineers deploy redundancy to eliminate single points of failure. This technical guide evaluates Hot Standby vs. Cold Standby architectures, comparing failover speeds, memory sync, cost trade-offs, and field selection criteria.

Read more