Skip to content

What are you looking for?


You may also like

ABB UNS2882A-P,V1 3BHE003855R0001 Interface BoardABB UNS2882A-P,V1 3BHE003855R0001 Interface BoardABB UNS2882A-P,V1 3BHE003855R0001 Interface Board
ABB UNS2882A-P,V1 3BHE003855R0001 Interface Board
ABB UNS2882A-P,V1 3BHE003855R0001 Interface Board
ABB UNS2882A-P,V1 3BHE003855R0001 Interface Board

ABB UNS2882A-P,V1 3BHE003855R0001 Interface Board


Only 10 left - Selling fast

PRODUCT SKU : UNS2882A-P,V1 3BHE003855R0001

PRODUCT TYPE : Interface Modules

PRODUCT VENDOR : ABB


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The ABB UNS2882A-P (3BHE003855R0001 Interface Board), also cataloged as the UNS2882A-P,V1 Interface Board, operates as a dedicated hardware component for signal transmission and data communication within industrial control networks.

Hardware Specifications

Parameter Specification
Model UNS2882A-P
Brand ABB
Part Number 3BHE003855R0001
Origin Switzerland
Weight 0.36 kg
Dimensions 255 mm x 240 mm x 35 mm
Operating Temp Standard industrial ambient
Power Consumption System backplane dependent

Profinet / EtherNet/IP deterministic networks

The UNS2882A-P module manages backplane bus communication velocity to ensure deterministic signal routing between interconnected control nodes. Its internal logic facilitates I/O density scaling, allowing for efficient data handling within high-speed control cycles. Firmware flash compatibility is intrinsically linked to the system's base software revision; engineers must verify the specific V1 revision requirements to ensure seamless integration. The interface board functions by isolating and buffering control signals, preventing bus timing discrepancies and ensuring the integrity of high-priority communication packets across the backplane architecture.

Frequently Asked Questions

Q: Is this interface board capable of hot-swapping while the system is powered?

A: No. Hot-swapping is prohibited. The backplane must be de-energized prior to removing or installing the board to avoid potential damage to the communication pins and integrated circuits caused by transient voltage spikes.

Q: How is the physical address or slot configuration managed for this board?

A: The board is configured via the system engineering software. It must be correctly mapped within the controller hardware scan list to allow for proper data exchange and interrupt prioritization across the backplane.

Field Installation Guidelines

  • Mounting: Ensure the board is firmly seated in the rack guide rails. Verify that the backplane connector is fully engaged and that the front-panel mounting screws are tightened to guarantee mechanical stability.
  • Grounding: Establish a clean electrical path to the cabinet chassis ground. This is mandatory for mitigating electromagnetic interference (EMI) and maintaining the signal reference levels required for stable bus communication.
  • Wiring: Route all communication and I/O cabling through dedicated trays. Maintain physical separation from high-current power cables to minimize inductive coupling and potential data errors.
  • Inspection: Prior to installation, conduct a visual check of the gold-plated connector contacts for oxidation or debris. Ensure the PCB surface is free of moisture or conductive contaminants.
  • Maintenance: Periodically check that all cable connections are secure and that the surrounding cooling environment allows for adequate thermal dissipation of the module's logic components.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Navigating Industrial Automation Failures: Types, Causes, and Mitigation Strategies

Modern manufacturing relies heavily on automated control systems to maximize throughput and maintain product quality. However, unplanned downtime in industrial automation can cost facility operators thousands of dollars per hour. Understanding how programmable logic controllers (PLCs), distributed control systems (DCS), and field instrumentation fail empowers engineering teams to implement robust preventive maintenance strategies.

Read more
Essential Motion Control Commands: A Practical Guide for Engineers

Essential Motion Control Commands: A Practical Guide for Engineers

Automation engineers often rely on precise position and speed control to drive modern factory machinery. Modern industrial systems, such as Programmable Logic Controllers (PLCs) and Distributed Control Systems (DCS), depend heavily on standardized motion instructions. Mastering these commands ensures operational safety, protects mechanical components, and optimizes cycle times across production lines.

Read more
The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

The Role of Intrinsic Safety Barriers in PLC and DCS Architectures

Implementing robust protection in hazardous industrial environments represents a fundamental safety requirement in factory automation. Process facilities often handle volatile gases, dusts, and chemical agents that pose significant combustion risks. Consequently, control system engineers must deploy energy-limiting interfaces to isolate safe-area control cabinets from hazardous-area field instrumentation. This article examines the function, selection, and electrical principles of intrinsic safety barriers within modern PLC and DCS networks.

Read more