Skip to content

What are you looking for?


You may also like

ABB UNS0880A-P,V1 3BHB005922R0001 Control Interface Node BoardABB UNS0880A-P,V1 3BHB005922R0001 Control Interface Node BoardABB UNS0880A-P,V1 3BHB005922R0001 Control Interface Node Board
ABB UNS0880A-P,V1 3BHB005922R0001 Control Interface Node Board
ABB UNS0880A-P,V1 3BHB005922R0001 Control Interface Node Board
ABB UNS0880A-P,V1 3BHB005922R0001 Control Interface Node Board

ABB UNS0880A-P,V1 3BHB005922R0001 Control Interface Node Board


Only 10 left - Selling fast

PRODUCT SKU : UNS0880A-P,V1 3BHB005922R0001

PRODUCT TYPE : Control Circuit Boards

PRODUCT VENDOR : ABB


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Configured for high-speed signal distribution and system control in ACS6000 and Megadrive-LCI drive platforms, the ABB UNS0880A-P,V1 3BHB005922R0001 (UNS0880A-P,V1 Control Interface Node Board) provides direct physical/electrical execution.

Hardware Specifications

Parameter Specification
Model UNS0880A-P,V1 (3BHB005922R0001)
Brand ABB
Origin Sweden
Weight 0.62 kg
Dimensions 350 mm x 117 mm x 30 mm
Operating Temp Standard Control Enclosure (-10 to 60 deg C)
Power Consumption 24 VDC Internal Control Power
Board Type Control Interface Node (CIN) PCB Assembly
System Platform ABB ACS6000 / Megadrive-LCI Medium Voltage Drives

Deterministic Network Integration and I/O Density Scaling

The UNS0880A-P,V1 board interfaces with central controller racks to route high-speed drive commands across Profinet and EtherNet/IP deterministic networks. Its multi-layer circuit layout optimizes backplane bus communication velocity and supports scalable I/O density scaling across medium-voltage power stacks. Onboard flash microcontrollers ensure firmware flash compatibility during online parameter synchronization and system diagnostics.

Frequently Asked Questions

Q: Can the UNS0880A-P,V1 board be hot-swapped while the converter control rack is energized?

A: No, control supply power must be isolated prior to removing or installing the CIN PCB to prevent bus voltage transients and logic damage.

Q: How is chassis grounding established for the UNS0880A-P,V1 printed circuit board?

A: Frame earthing is maintained through dedicated metallic mounting standoffs that contact the grounded card cage structure upon installation.

Q: What primary function does the CIN PCB perform in drive assemblies?

A: The board acts as a central control interface node, mediating signal transfer between local sensor/gate-driver sub-assemblies and the main processing unit.

Field Installation Guidelines

  • De-energize all main medium-voltage power components and auxiliary 24 VDC control buses prior to opening the card frame.
  • Wear an grounded anti-static wrist strap during handling to protect sensitive CMOS circuits from electrostatic discharge.
  • Verify that edge connectors align cleanly with backplane slots before applying insertion pressure to avoid pin deformation.
  • Torque all retention screws to specified engineering standards to guarantee low-impedance ground bonding across the enclosure chassis.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
The Shift to Flexible IO Modules in Modern Industrial Automation

The Shift to Flexible IO Modules in Modern Industrial Automation

Traditional control systems rely on dedicated Input Output (IO) cards for industrial automation. Each conventional module processes a single signal type, such as Digital Input (DI), Digital Output (DO), Analog Input (AI), or Analog Output (AO). A standard 16-channel card accepts only one specific channel type across all ports. This inflexible hardware design often creates severe engineering bottlenecks during project execution. Engineers frequently must install entirely new cards to accommodate a single extra sensor. Consequently, late design changes increase control cabinet space requirements and drive up project costs.

Read more
DCS Commissioning Steps in Industrial Automation Projects

DCS Commissioning Steps in Industrial Automation Projects

Commissioning a Distributed Control System (DCS) represents a crucial milestone when deploying modern process automation infrastructure. Field engineers must execute systematic verification steps to transition complex control hardware from static installation to dynamic plant control. Proper commissioning ensures that controllers, I/O modules, network switches, and HMI software operate in strict compliance with engineering design specifications before introducing live process fluids.

Read more
PLC and DCS Control System Spares Strategy: Engineering Guidelines

PLC and DCS Control System Spares Strategy: Engineering Guidelines

Modern factory automation relies on high-speed fiber optic backbones to link distributed control systems across noise-intensive industrial environments. Unlike copper wiring, optical fibers transmit data via light pulses, making them completely immune to electromagnetic interference (EMI). Field engineers must master optical cable joining and fusion splicing techniques to guarantee low-loss data transmission across critical Programmable Logic Controller (PLC) and Distributed Control System (DCS) nodes.

Read more