Product Details
Configured for high-voltage DC to AC power conversion in ABB drive systems, the ABB UB C717 AE101 HIEE300927R0101 (UBC717AE101 High Voltage Inverter Board) provides direct physical/electrical execution.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | UB C717 AE101 (HIEE300927R0101) |
| Brand | ABB |
| Origin | Sweden |
| Weight | 0.1 kg |
| Dimensions | 12.7 cm x 5.1 cm x 12.7 cm |
| Operating Temp | -20 to 70 deg C |
| Power Consumption | Powered via 24 VDC control input rail |
| Control Input Voltage | 24 VDC |
| High Voltage DC Input | 400 to 800 VDC |
| Output Voltage | 0 to 400 VAC |
| Output Current | Up to 10 A |
| Efficiency | Over 98% |
| Protection Class | IP67 |
Backplane Bus Communication Velocity and Firmware Flash Compatibility
The UB C717 AE101 HIEE300927R0101 inverter board processes switching pulses without disrupting backplane bus communication velocity across control node networks. Hardware-level switching gates convert high-voltage DC input (400 to 800 VDC) to continuous 0 to 400 VAC output with conversion efficiency exceeding 98%. Standardized firmware flash compatibility across connected controller processors ensures deterministic control cycles and supports scalable I/O density scaling during dynamic load variation.
Frequently Asked Questions
Q: What power inputs are required to operate the UB C717 AE101 HIEE300927R0101 inverter board?
A: The board requires a 24 VDC control power supply alongside a primary 400 to 800 VDC input link for high-voltage power conversion.
Q: What protection rating applies to the module assembly housing?
A: The board assembly holds an IP67 protection rating for ingress protection against dust and water immersion.
Q: Can the inverter board be safely serviced or removed while the DC bus is energized?
A: No, all primary 400 to 800 VDC supply feeds and 24 VDC auxiliary control power must be completely isolated and verified discharged before handling the circuit board.
Field Installation Guidelines
- Disconnect main 400-800 VDC power supplies and 24 VDC control feeds prior to handling the module.
- Confirm zero potential across high-voltage bus capacitor terminals using a calibrated voltmeter.
- Attach a grounded ESD wrist strap before touching circuit board edge connections or surface-mount components.
- Mount the board onto the designated chassis standoff positions and tighten fasteners to secure structural grounding.
- Inspect power terminal connections to ensure solid contact pressure and prevent high-current electrical arc faults.
Additional Information
- 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
- 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
- 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
- Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
- Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
- Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.