Product Details

The ABB IM/C1900OGR, also cataloged as the IM/C1900OGR Circular Chart Recorder, operates as a dedicated hardware component for multi-channel analog signal acquisition and physical chart trace rendering within ABB Commander 1900 system platforms.

Hardware Specifications

Parameter Specification
Model IM/C1900OGR
Brand ABB
Origin United Kingdom
Weight 4.5 kg
Dimensions Standard Commander 1900 enclosure dimensions
Operating Temp -10 to +55 deg C
Power Consumption 100-240 VAC or 24 VDC nominal supply load
Supported Inputs mV (high impedance), Voltage (V), Current (mA), Thermocouple, 2-wire transmitter
Monitored Variables Temperature, Pressure, Flow, and general industrial process variables
Format Circular paper chart with printed operator guidance and alarm threshold markers
Product Type Circular Chart Recorders

Firmware Flash Compatibility and I/O Density Scaling

The internal signal processing board utilizes dedicated microprocessor circuitry to handle multi-channel analog-to-digital signal conversion while maintaining firmware flash compatibility across the Commander 1900 hardware line. High I/O density scaling allows simultaneous processing of temperature, pressure, and flow loops, driving servo-positioned pen mechanisms without degrading scan response velocity or signal resolution.

Frequently Asked Questions

Q: What precautions are necessary when connecting high-impedance mV or thermocouple inputs to the IM/C1900OGR?

A: High-impedance signal cabling must use shielded twisted pairs routed separately from AC power lines. The drain wire must be terminated to a single protective earth point at the recorder frame to prevent electrical noise interference.

Q: Can 2-wire process transmitters be powered directly by the recorder input terminals?

A: Yes. The internal loop supply capability allows standard 2-wire current transmitters to be powered directly through the input terminal block without an external power supply.

Field Installation Guidelines

  1. Cut the panel opening according to standard Commander 1900 mounting dimensions and verify panel structural rigidity for the recorder weight.
  2. Insert the unit through the cutout and secure the side mounting clamps until the bezel gasket compresses evenly against the panel surface.
  3. Terminate signal leads, thermocouple extension wires, and power connections at the terminal block in accordance with the channel wiring key.
  4. Connect a dedicated protective earth (PE) grounding conductor to the main grounding stud on the rear enclosure prior to applying line power.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Mastering the Siemens PLC Scan Cycle: How the CPU Executes Automation Programs

Mastering the Siemens PLC Scan Cycle: How the CPU Executes Automation Programs

Industrial automation relies heavily on programmable logic controllers (PLCs) to manage complex manufacturing processes. Many engineers dive straight into programming without mastering the underlying architecture. However, understanding how a PLC CPU executes a program ensures reliable system design. Therefore, mastering the scan cycle optimizes both performance and troubleshooting in modern control systems.

Read more
How to Connect to Siemens S7 PLCs: 5 Essential Communication Methods

How to Connect to Siemens S7 PLCs: 5 Essential Communication Methods

Establishing a reliable hardware link between a programming terminal and a Siemens SIMATIC controller is essential for engineering workflows. Field engineers rely on distinct physical layers, ranging from legacy serial connections to high-speed Industrial Ethernet protocols. Modern factory automation environments prioritize fast data transfer and seamless driver integration. Selecting the correct connection method simplifies program downloads, online monitoring, and system troubleshooting in complex control systems.

Read more
Will PLCs Become Obsolete? The Future of Control Systems in Industry 4.0

Will PLCs Become Obsolete? The Future of Control Systems in Industry 4.0

Modern manufacturing is undergoing a rapid technological transformation driven by Industry 4.0 innovations. Technologies like Artificial Intelligence (AI), Machine Learning (ML), and the Industrial Internet of Things (IIoT) are dominating discussions across the factory automation sector. Consequently, many engineers wonder if these advanced digital tools will eventually replace traditional Programmable Logic Controllers (PLCs). However, evaluating the core physics of industrial operations reveals a very different reality for control systems.

Read more