Skip to content

What are you looking for?


You may also like

ABB FI 840F 3BDH000033R1 AC800F Fieldbus HSE Interface ModuleABB FI 840F 3BDH000033R1 AC800F Fieldbus HSE Interface ModuleABB FI 840F 3BDH000033R1 AC800F Fieldbus HSE Interface Module
ABB FI 840F 3BDH000033R1 AC800F Fieldbus HSE Interface Module
ABB FI 840F 3BDH000033R1 AC800F Fieldbus HSE Interface Module
ABB FI 840F 3BDH000033R1 AC800F Fieldbus HSE Interface Module

ABB FI 840F 3BDH000033R1 AC800F Fieldbus HSE Interface Module


Only 10 left - Selling fast

PRODUCT SKU : FI 840F 3BDH000033R1

PRODUCT TYPE : Communication Interface Modules

PRODUCT VENDOR : ABB


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The ABB FI 840F 3BDH000033R1, also cataloged as the FI840F Communication Interface Module, operates as a dedicated hardware component for high-speed deterministic network data exchange within AC800F controller system platforms. It manages bi-directional protocol processing directly at the backplane interface to establish reliable communication loops between process controllers and field-level instrumentation networks without introducing execution latency to the primary logic processor.

Hardware Specifications

Parameter Specification
Model FI 840F (3BDH000033R1)
Brand ABB
Origin Germany
Weight 0.15 kg (0.33 lbs)
Dimensions 125 mm x 155 mm x 28 mm (4.9 in x 6.1 in x 1.1 in)
Operating Temp -40 to 70 deg C (-40 to 158 deg F)
Power Supply 24 VDC
Communication Protocol FOUNDATION Fieldbus HSE (High-Speed Ethernet)
Transmission Speed 100 Mbps
Channel Count 4 or 8 channels (variant dependent)
Mounting Orientation Vertical or horizontal on dedicated AC800F carrier

Deterministic Ethernet Backplane and Firmware Scaling

The module handles high-throughput Fieldbus HSE network data packages by leveraging hardware-level deterministic execution across the controller system backplane. Firmware flash compatibility ensures synchronized cyclic and acyclic data transfers, maintaining tight timing alignment across all connected network nodes. This specialized interface offloads complex protocol stacks from the main central processor, stabilizing execution scan times during periods of high I/O density and heavy network traffic.

Frequently Asked Questions

Q: What precautions should be observed when replacing the module on an active AC800F rack?

A: Ensure the controller rack supports online module exchange and verify that all system configurations are backed up. Electrostatic discharge protection must be worn during insertion to prevent damage to sensitive backplane bus logic pins.

Q: How is fieldbus network traffic isolated from internal controller logic?

A: The module incorporates built-in galvanic isolation and internal protocol processing hardware to separate the high-speed Ethernet physical layer from the backplane controller bus, preventing transient electrical interference from propagating.

Field Installation Guidelines

  • Verify that the 24 VDC system power supply is isolated or regulated within specified tolerances prior to seating the module into the rack position.
  • Maintain minimum physical clearance around the module housing to enable unrestricted convection airflow across the operating temperature range of -40 to 70 deg C.
  • Route high-speed communication cables separately from high-voltage AC lines to minimize electromagnetic cross-talk.
  • Ensure all Ethernet and field bus shielded cabling is correctly bonded to the protective earth ground point at a single terminal interface.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Demystifying the 5 Levels of Industrial Automation Architecture

Demystifying the 5 Levels of Industrial Automation Architecture

Modern manufacturing relies on structured communication hierarchy to bridge physical shop-floor hardware with enterprise management software. This framework, commonly known as the Automation Pyramid, establishes how data flows between field devices, logic controllers, and corporate IT networks. Understanding these five distinct levels helps engineers and plant managers optimize system operations, reduce downtime, and implement seamless factory automation solutions.

Read more
Transforming Shop Floor Data into Actionable Insights: A Deep Dive into MES

Transforming Shop Floor Data into Actionable Insights: A Deep Dive into MES

Manufacturing Execution Systems serve as the digital backbone of modern factory floors. Positioned at Level 3 of the ISA-95 automation pyramid, MES links enterprise resource planning with real-time shop floor control systems. Today, industrial operators rely on MES software to bridge operational strategy with physical production execution.

Read more
Managed Switch vs. Unmanaged Switch: Industrial Ethernet Architecture

Managed Switch vs. Unmanaged Switch: Industrial Ethernet Architecture

Industrial Ethernet forms the backbone of factory automation. Selecting the right switch architecture determines system uptime, data throughput, and OT cyber resilience. This technical guide evaluates managed vs. unmanaged switches, analyzing operational differences, security controls, and selection criteria.
Read more