Product Details

The ABB 26390603-A, also cataloged as the DSTK 150 Cable Assembly, operates as a dedicated hardware component for internal bus signal interconnections within ABB Advant Master Process Control Systems.

Hardware Specifications

Parameter Specification
Model DSTK 150
Order Code 26390603-A
Brand ABB
Origin Sweden / EU
Product Type Cable Assemblies
Cable Type Flat ribbon cable assembly
Cable Length 3.0 m
Cable Diameter 1 mm
Connector Configuration 64-pin to 40-pin
Weight 0.24 kg
Dimensions 3.0 m length x 1 mm thickness
Operating Temp 0 to 55 deg C
Power Consumption Passive physical conductor assembly
RoHS Compliance Exempt from 2011/65/EU (RoHS) under Article 2(4)
WEEE Category Product not within WEEE scope

Backplane Bus Communication & Field I/O Density Scaling

The ABB DSTK 150 flat ribbon cable assembly facilitates high-speed parallel bus communications between rack sub-assemblies and termination units in Advant Master architectures. Transitioning from a 64-pin connector to a 40-pin header interface, the assembly maintains low signal latency and impedance consistency across all conducting pairs. The multi-core ribbon geometry minimizes cross-talk interference while supporting scalable I/O density routing across dense control cabinet configurations.

Frequently Asked Questions

Q: What pin transition does the DSTK 150 cable assembly perform between hardware sub-assemblies?

A: The ribbon assembly interfaces a 64-pin system backplane connector directly to a 40-pin target termination card or subrack connector.

Q: Is hot-unplugging permitted for the DSTK 150 cable during system operation?

A: Ribbon cable disconnection must only be performed after de-energizing the subrack segment to prevent bus logic errors or electrical voltage transients across active I/O cards.

Field Installation Guidelines

  1. Verify subrack power is switched off prior to installing or removing the ribbon assembly.
  2. Align the 64-pin and 40-pin connector keyed slots with the corresponding male headers on the backplane or terminal board.
  3. Apply uniform pressure across the connector body until the side locking clips snap securely into place.
  4. Avoid tight bending radii or sharp twists in the 1 mm flat ribbon body to prevent internal conductor fracturing.
  5. Ensure the cable path is routed clear of high-power AC lines and sharp metal edges within the cabinet frame.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Comprehensive Guide to Instrumentation and Control (I&C) Design Basis

Comprehensive Guide to Instrumentation and Control (I&C) Design Basis

Instrumentation and Control (I&C) Design Basis serves as the foundational technical document for modern plant engineering. Project teams rely on this master specification to govern engineering deliverables across front-end engineering design (FEED) and detailed execution phases. A well-constructed I&C design basis ensures seamless integration among field instrumentation, safety systems, and main control systems. Furthermore, establishing clear technical standards early mitigates execution risks and prevents costly re-engineering during plant commissioning.

Read more
The Shift to Flexible IO Modules in Modern Industrial Automation

The Shift to Flexible IO Modules in Modern Industrial Automation

Traditional control systems rely on dedicated Input Output (IO) cards for industrial automation. Each conventional module processes a single signal type, such as Digital Input (DI), Digital Output (DO), Analog Input (AI), or Analog Output (AO). A standard 16-channel card accepts only one specific channel type across all ports. This inflexible hardware design often creates severe engineering bottlenecks during project execution. Engineers frequently must install entirely new cards to accommodate a single extra sensor. Consequently, late design changes increase control cabinet space requirements and drive up project costs.

Read more
DCS Commissioning Steps in Industrial Automation Projects

DCS Commissioning Steps in Industrial Automation Projects

Commissioning a Distributed Control System (DCS) represents a crucial milestone when deploying modern process automation infrastructure. Field engineers must execute systematic verification steps to transition complex control hardware from static installation to dynamic plant control. Proper commissioning ensures that controllers, I/O modules, network switches, and HMI software operate in strict compliance with engineering design specifications before introducing live process fluids.

Read more