Skip to content

What are you looking for?


You may also like

ABB CMA 112 3D DE3 000 13 Diesel Control Display UnitABB CMA 112 3D DE3 000 13 Diesel Control Display UnitABB CMA 112 3D DE3 000 13 Diesel Control Display Unit
ABB CMA 112 3D DE3 000 13 Diesel Control Display Unit
ABB CMA 112 3D DE3 000 13 Diesel Control Display Unit
ABB CMA 112 3D DE3 000 13 Diesel Control Display Unit

ABB CMA 112 3D DE3 000 13 Diesel Control Display Unit


Only 10 left - Selling fast

PRODUCT SKU : CMA 112 3D DE3 000 13

PRODUCT TYPE : Diesel Control Display Unit

PRODUCT VENDOR : ABB


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

The ABB CMA 112 3D DE3 000 13 serves as the primary CMA 112 Diesel Engine Control Display Panel utilized to execute real-time monitoring and precision control of diesel generator sets across industrial engine platforms. The assembly interfaces directly with discrete and serial engine instrumentation channels, processes multi-protocol fuel state and speed vectors, and outputs algorithmic actuation signals via integrated communication interfaces to regulate physical prime mover sub-elements under changing load balances.

Hardware Specifications

Parameter Specification
Model CMA 112 3D DE3 000 13 (CMA112)
Brand ABB
Origin Sweden / Germany (Standard production matrix baseline)
Weight 0.7 kg
Dimensions 152 mm x 152 mm x 76 mm
Display Size 12-inch LCD touchscreen
Resolution 1280 x 800 pixels
Memory 256 MB RAM, 512 MB Flash
Communication Interfaces RS-485, CANopen, Ethernet
Power Supply 12 VDC / 24 VDC options
Operating Temp -20 to +50 deg C
Product Type Diesel Engine Control Display Panels

Profinet / EtherNet/IP Deterministic Networks and I/O Density Scaling

The internal runtime environment of the ABB CMA 112 3D DE3 000 13 bridges localized machine-level protocols directly into higher-tier system architectures. When engine parameters are aggregated from the CANopen interface and broadcasted over Profinet or EtherNet/IP deterministic networks via the onboard Ethernet adapter, the data packet scheduling mechanisms prevent frame latency spikes. The display and memory architecture handle sudden structural data point updates smoothly during periods of rapid system growth or broad I/O density scaling, provided all sub-node telemetry modifications maintain matching host controller firmware flash compatibility parameters.

Frequently Asked Questions

Q: Can the power terminals or communication interface cables of the CMA 112 panel be hot-swapped while the diesel generator is actively running?

A: No. The unit must not be disconnected while auxiliary power or live bus communication is active. Removing serial or power contacts under active engine operation risks high-voltage inductive arcing, causing total data packet dropouts, sudden engine shutdown interlocks, or physical breakdown of the internal transceivers.

Q: How is a memory synchronization failure or firmware flash compatibility conflict indicated?

A: System hardware conflicts are registered via automated boot diagnostics on the 12-inch LCD interface. If a flash validation error occurs, hardware parameter blocks must be verified against the core engine controller profile to match required runtime communication constraints.

Field Installation Guidelines

  1. ESD Handling Measures: Technical field operators must wear a properly connected and grounded electrostatic discharge (ESD) wrist strap prior to interfacing with unshielded backplane connections or wiring blocks to block latent tracking breakdown.
  2. Panel Cutout Optimization: Mount the 0.7 kg enclosure flush within a prepared, low-vibration metal cutout. Secure all integrated edge clamps evenly to achieve complete gasket seal seating, mitigating moisture ingress and panel warping.
  3. Control Conduit and Routing Rules: Group and route the RS-485, CANopen, and Ethernet cables inside separate low-voltage wireways. Maintain a physical distance of at least 100 mm from three-phase AC generator outputs or high-current motor starter links to prevent inductive noise injection.
  4. Power Supply Conditioning: Verify that external 12 VDC or 24 VDC auxiliary power sources sit within design-specified noise tolerances. Use short, dedicated ground straps to connect the housing ground terminal directly to the machine chassis ground point.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Mitigating Emergency Stop Spurious Trips in Industrial Control Systems

Mitigating Emergency Stop Spurious Trips in Industrial Control Systems

Emergency stop (E-Stop) pushbuttons serve as vital safety devices in factory automation and process control plants. Functional safety standards mandate normally-closed (NC) contact blocks to ensure fail-safe operation during wiring breaks or power outages. However, mechanical degradation over time can trigger unexpected spurious trips, halting production lines without an actual emergency. Understanding the underlying causes of mechanical contact failure allows automation engineers to implement robust, fault-tolerant safety circuits.

Read more
Redundant Automation Systems: Maximizing Uptime in Critical Control Applications

Redundant Automation Systems: Maximizing Uptime in Critical Control Applications

Industrial automation relies on continuous operational stability to prevent catastrophic downtime and financial loss. While standard dictionary definitions treat redundancy as superfluous, industrial engineers consider redundant control architectures indispensable for high-availability systems. Implementing backup hardware ensures seamless takeover during primary equipment failures, protecting critical infrastructure across manufacturing and process industries.

Read more
Demystifying the 5 Levels of Industrial Automation Architecture

Demystifying the 5 Levels of Industrial Automation Architecture

Modern manufacturing relies on structured communication hierarchy to bridge physical shop-floor hardware with enterprise management software. This framework, commonly known as the Automation Pyramid, establishes how data flows between field devices, logic controllers, and corporate IT networks. Understanding these five distinct levels helps engineers and plant managers optimize system operations, reduce downtime, and implement seamless factory automation solutions.

Read more