Description

The CI867K01 interface kit enables Modbus TCP connectivity as a master or slave on an Ethernet network. It includes the CI867 communication module and necessary installation components. Designed for complex industrial communication, it supports multiple connections and high data throughput. Using standard Ethernet infrastructure, it minimizes cabling needs and provides advanced diagnostics via ABB engineering tools. Its rugged design ensures reliable performance in demanding environments, maintaining stable network connections for critical data.

Specifications

  • Manufacturer: ABB

  • Country of Origin: Sweden / Estonia

  • Model Number: CI867K01

  • Order Number: 3BSE043660R1

  • Product Type: Modbus TCP Communication Interface Kit

  • Protocol Support: Modbus TCP (Master and Slave modes)

  • Hardware Composition: Includes CI867 module and TP867 baseplate

  • Ethernet Ports: Dual RJ45 ports for network redundancy

  • Transmission Speed: 10/100 Mbps (Autosensing)

  • Power Consumption: 24 V DC (via ModuleBus)

  • Operating Temperature: +5 to +55 Celsius

  • Ingress Protection: IP20

Features

  • Dual Port Redundancy: Equipped with two Ethernet interfaces to support redundant network topologies, ensuring continuous communication during single-cable failures.

  • Flexible Protocol Role: Operates as either a Modbus TCP Client (Master) or Server (Slave), providing versatile integration options for diverse field devices.

  • High Connection Capacity: Supports a large number of concurrent Modbus TCP transactions, making it suitable for high-density data acquisition tasks.

  • Controller Integration: Designed specifically for the AC 800M series, allowing for direct configuration and monitoring via Control Builder M.

  • Modular Maintenance: Supports hot-swap functionality when used with compatible baseplates, enabling module replacement without disrupting the controller's operation.

  • Standardized Networking: Leverages standard TCP/IP protocols to simplify integration with existing corporate and plant-wide Ethernet infrastructures.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Mastering Wire Identification in Industrial Automation: The Power of Ferrules and Cross-Ferruling

Mastering Wire Identification in Industrial Automation: The Power of Ferrules and Cross-Ferruling

Proper wire labeling forms the cornerstone of reliable control system installation and long-term maintenance. In complex industrial automation environments, technicians terminate thousands of conductor ends inside control panels, marshalling racks, and field junction boxes. Ferrules serve as individual tube-shaped sleeve markers slipped onto conductors before final termination. While technicians historically relied on pre-printed individual letter rings, modern control panel builders utilize automated ferrule printing machines. These thermal-transfer printers generate durable, single-sleeve heat-shrink tags directly matching approved wiring schematics, significantly accelerating cabinet assembly workflows.

Read more
Understanding Marshalling Cabinets in Industrial Automation and Control Systems

Understanding Marshalling Cabinets in Industrial Automation and Control Systems

Marshalling cabinets serve as the crucial connection hub between field instruments and centralized processing units. In large DCS and PLC control system architectures, hundreds of multipair field cables run from local junction boxes to the central instrument equipment room. The marshalling cabinet houses field terminal blocks, surge arresters, intrinsic safety isolation barriers, and interposing relays. By segregating field field-wiring terminations from sensitive processor hardware, engineers protect expensive controller backplanes from high-voltage transients. Consequently, this modular separation dramatically streamlines maintenance workflows and simplifies system expansion.

Read more
Essential Best Practices for PLC Wiring and Installation in Industrial Automation

Essential Best Practices for PLC Wiring and Installation in Industrial Automation

Successful control system deployment begins with thoroughly reviewing manufacturer technical documentation. Controllers from major brands like Allen-Bradley, Siemens, and Schneider Electric feature unique terminal layouts. Engineers must verify voltage requirements before connecting power cables to prevent catastrophic equipment damage. Standard line connections require strict adherence to regional electrical codes and proper wire color coding. Furthermore, panel builders should always establish a robust low-impedance ground connection using at least 16-AWG copper conductor tied directly to the main plant grounding grid.

Read more