Only 10 left - Selling fast

PRODUCT SKU : CI534V02 3BSE010700R1

PRODUCT TYPE : Analog Input Module

PRODUCT VENDOR : ABB


  • 100% Genuine Parts – Risk-Free 30-Day Returns
  • 1-Year Warranty & Expert Support for Every Order

Product Details

Product Overview

The ABB CI534V02 (3BSE010700R1) functions as a high-performance communication submodule designed for the Advant OCS (Open Control System) environment. This module provides two independent channels for MODBUS RTU serial communication, enabling seamless integration between ABB controllers and third-party devices such as power meters, frequency drives, and specialized field sensors. It translates complex external data into system-native variables, ensuring real-time visibility across the DCS network. We supply this unit as 100% Brand New and Original, maintaining factory-sealed standards for critical infrastructure stability.

Technical Specifications

The CI534V02 utilizes a specialized dual-port architecture to manage concurrent data streams:

  • Article Number: 3BSE010700R1

  • Module Type: Communication Submodule

  • Interface Protocol: MODBUS (Serial)

  • Number of Channels: 2 Independent Channels

  • Net Weight: 0.155 kg

  • Product Dimensions: 108 mm (W) x 27 mm (H) x 238.5 mm (D)

  • HS Code: 85176200

  • Country of Origin: Sweden

  • Compatibility: ABB Advant OCS Controller Subracks

Engineering Advantages

  • Dual-Channel Efficiency: The CI534V02 integrates two physical MODBUS ports within a single submodule footprint. This design allows the controller to communicate with two separate device networks simultaneously, doubling the connectivity density without requiring additional rack slots.

  • Optimized Signal Integrity: The hardware implements advanced filtering to suppress electromagnetic interference (EMI) typical in high-voltage industrial environments. This ensures stable data packet transmission even when routing serial cables alongside motor power leads.

  • Seamless Backplane Integration: The submodule utilizes a high-reliability plug-in connector that interfaces directly with the master communication module or controller backplane. This secure physical connection prevents signal loss caused by mechanical vibration or thermal cycling in 24/7 process operations.

  • Broad Device Interoperability: By adhering to the standard MODBUS RTU protocol, the CI534V02 opens the Advant OCS to thousands of third-party instruments. It simplifies the integration of specialized equipment, allowing the DCS to act as a centralized data aggregator.

  • Low Thermal Footprint: Despite managing dual active channels, the module utilizes low-power CMOS technology to minimize heat dissipation. This allows for high-density mounting in enclosed cabinets where airflow remains restricted.

FAQs

  • Can the CI534V02 replace the older V01 version?

    The CI534V02 represents a hardware revision that enhances component longevity and timing stability. It generally maintains backward compatibility; however, we recommend verifying your specific controller firmware version to ensure the driver recognizes the V02 hardware signature.

  • Does this submodule require a separate power supply?

    No. The CI534V02 draws the required logic power directly from the host module or backplane interface. This eliminates the need for external 24V DC wiring at the submodule level.

  • How do I configure the baud rate and parity for each channel?

    You define the communication parameters (Baud rate, Parity, Data bits, and Stop bits) within the Advant OCS engineering tool. Each channel supports independent configuration, allowing you to connect devices with different speeds to the same module.

  • What is the maximum cable length supported for the MODBUS link?

    The serial physical layer typically supports distances up to 1200 meters (4000 feet) at lower baud rates. We recommend using high-quality shielded twisted-pair (STP) cable and proper end-of-line termination to ensure data integrity over long distances.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
Understanding Dynamic Data Exchange (DDE) in Industrial Automation

Understanding Dynamic Data Exchange (DDE) in Industrial Automation

Dynamic Data Exchange (DDE) remains a vital legacy protocol for industrial communication. Originally for general computing, it now bridges the gap between factory floor data and enterprise reporting. This enduring method provides a foundational link for integrating real-time software layers in modern industrial automation.

Read more
Master FIFO and LIFO Sequences for Advanced PLC Logic

Master FIFO and LIFO Sequences for Advanced PLC Logic

In industrial automation, managing data flow is as critical as hardware control. This guide explores how FIFO and LIFO sequential logic can optimize your control systems. Master these essential tools to build more efficient sorting, inventory tracking, and data management workflows for any modern factory.

Read more
Power Cables vs. Signal Cables: Essential Guidelines for Industrial Automation

Power Cables vs. Signal Cables: Essential Guidelines for Industrial Automation

In industrial automation, distinguishing between power and signal cabling is vital. While power cables deliver energy to machinery, signal cables transmit critical data to control systems. This guide explores their technical differences and explains why proper isolation is the key to a reliable, interference-free factory automation network.

Read more