The ABB 560ETH02 1KGT009200R0001, also cataloged as the 560ETH02 Ethernet Communication Module, operates as a dedicated hardware component for network interface bridging and Ethernet data routing within ABB RTU560 platforms.

Hardware Specifications

Parameter Specification
Model 560ETH02 1KGT009200R0001
Brand ABB
Origin Germany
Operating Temp -40 to +70 deg C
Power Consumption 2 W Typical
Power Supply 5 VDC via Backplane Bus
Communication Interface 2 x Ethernet Network Ports
Target System ABB RTU560 System Subracks

Deterministic Network Integration and I/O Density Scaling

The 560ETH02 interface card facilitates dual-port packet switching across Profinet and EtherNet/IP deterministic networks, enabling parallel communication channels directly from the RTU backplane. Optimized internal bus decoding maintains high backplane bus communication velocity to minimize packet conversion latency during intensive telecontrol polling routines. Compact subrack form-factor design preserves I/O density scaling inside subrack frames, while onboard flash memory guarantees full firmware flash compatibility during remote system maintenance and software revision updates.

Frequently Asked Questions

Q: How does the 560ETH02 draw operational logic power inside the RTU rack?

A: Power is supplied directly at 5 VDC through the system backplane connector, consuming 2 W under typical operational loads without requiring external DC wiring.

Q: Are the two Ethernet ports on the front panel individually configurable?

A: Yes, the dual Ethernet ports support independent network node addresses to enable redundant network topologies or distinct LAN segment routing.

Q: What environmental thermal thresholds must be observed during enclosure layout?

A: Operating temperature range is -40 to +70 deg C. Adequate natural convection cooling must be maintained across the subrack slots to avoid thermal throttling.

Field Installation Guidelines

  • Verify that subrack power is completely turned off before inserting or removing the 560ETH02 module from the backplane guide rails.
  • Use industrial-grade shielded Category 5e or Category 6 Ethernet cables with RJ45 metal-shielded connectors.
  • Ground cable shields to the main cabinet earth rail to mitigate high-frequency electromagnetic interference.
  • Tighten the module top and bottom retaining screws to ensure continuous chassis grounding contact with the subrack frame.

Additional Information

  • 100% Genuine Parts: All products are original and authentic, ensuring reliable industrial performance.
  • 30-Day Refund Guarantee: Return any in-stock item within 30 days in original, unopened packaging for a full refund (excluding shipping and fees).
  • 12-Month Warranty: Covers defects in materials or workmanship; excludes misuse, normal wear, or unauthorized modifications.
  • Worldwide Shipping: We ship via USPS, UPS, FedEx, and DHL. Delivery times vary by country and may be subject to customs or import fees.
  • Support & Contact: Technical and warranty assistance is available anytime. Contact us here: Contact.
  • Purchase Guidance: Check product specifications and compatibility carefully before ordering to ensure proper application.




Recently Viewed Products

Tech & Buying Guide

Technical Insights, Installation Guides, and Buying Tips
The Shift to Flexible IO Modules in Modern Industrial Automation

The Shift to Flexible IO Modules in Modern Industrial Automation

Traditional control systems rely on dedicated Input Output (IO) cards for industrial automation. Each conventional module processes a single signal type, such as Digital Input (DI), Digital Output (DO), Analog Input (AI), or Analog Output (AO). A standard 16-channel card accepts only one specific channel type across all ports. This inflexible hardware design often creates severe engineering bottlenecks during project execution. Engineers frequently must install entirely new cards to accommodate a single extra sensor. Consequently, late design changes increase control cabinet space requirements and drive up project costs.

Read more
DCS Commissioning Steps in Industrial Automation Projects

DCS Commissioning Steps in Industrial Automation Projects

Commissioning a Distributed Control System (DCS) represents a crucial milestone when deploying modern process automation infrastructure. Field engineers must execute systematic verification steps to transition complex control hardware from static installation to dynamic plant control. Proper commissioning ensures that controllers, I/O modules, network switches, and HMI software operate in strict compliance with engineering design specifications before introducing live process fluids.

Read more
PLC and DCS Control System Spares Strategy: Engineering Guidelines

PLC and DCS Control System Spares Strategy: Engineering Guidelines

Modern factory automation relies on high-speed fiber optic backbones to link distributed control systems across noise-intensive industrial environments. Unlike copper wiring, optical fibers transmit data via light pulses, making them completely immune to electromagnetic interference (EMI). Field engineers must master optical cable joining and fusion splicing techniques to guarantee low-loss data transmission across critical Programmable Logic Controller (PLC) and Distributed Control System (DCS) nodes.

Read more